I want to search for...
Permit #2005100118
Permit Details
Status: COED
| Parcel Id: 07-11-31-7009-00110-0180 |
| CONDITIONED SPACE: 3354 sqft |
| GARAGE: 1094 sqft |
| OPENED PORCH (WITH ROOF) : 220 sqft |
| OPENED PORCH (WITH ROOF) : 152 sqft |
| Total Square Footage: 4820 sqft |
| Block: 11 |
| Subdivision: - |
| Job Phone: (386)447-8680 |
| Location Address: 56 FARMSWORTH DR |
| Type: DU - DUPLEX |
| Issue Date: 01/06/2006 |
| NOC: RECORDED |
| Applicant name: MICHAEL LEO BRANIFF |
| Owner: RIVER CITY HOMES & DEVELOPMENT CORP. |
|
Address 145 CYPRESS POINT PKWY UNIT 105 PALM COAST, FL 32164 |
| Lot: 18 |
| Contracted Stated Job Value: ¤192,800.00 |
| Job Description: DUPLEX |
| Type: CN |
Contractor
RIVER CITY HOMES
| Status | Location Address | State License Number | Phone |
| CANCEL |
12058 SAN JOSE BLVD #804 Jacksonville, FL 32223 |
CGC062728 (Exp: 08/31/2012) | 904-260-9009 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 09/20/2006 | FINAL APPROVED | JGIBSON |
| UTILITY COMPANY FINAL | 09/19/2006 | APPROVED | MBACON |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 09/18/2006 | Disapproved - NO FEE | CBOEHME |
| Note: FAILED, CLEAN OUT HOLDING WATER THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 09/15/2006 | Disapproved - NO FEE | JSHEVLIN |
| Note: FAILED, CLEAN OUT HAS STANDING WATER | |||
| RESIDENTIAL EARLY POWER | 09/14/2006 | APPROVED | LHITES |
| UTILITY COMPANY FINAL | 09/13/2006 | Disapproved - NO FEE | JSHEVLIN |
| Note: FAILED, SEWER CLEAN OUT DUG UP AND EXPOSE HOLE FILLED WITH WATER CONTRACTOR MAKE REPAIR | |||
| STORMWATER FINAL INSPECTION | 09/08/2006 | APPROVED - AS NOTED | DRANDALL |
| Note: 43 sf road damage | |||
| DRIVEWAY | 08/08/2006 | APPROVED | DRANDALL |
| Note: THIS IS A REINSPECTION | |||
| DRIVEWAY | 08/04/2006 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: drainage is right to left as per swale sheet, right culvert pipe flows left to right, incorrect flow.....left culvert pipe is level, not correct pitch.....cut road edge at 90* not at a 45*.....need permit box accessible at time of inspection | |||
| INSULATION INSPECTION | 06/26/2006 | APPROVED | JGIBSON |
| ALL ROUGH | 06/22/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 06/21/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Still missing straps @ panel 12'' above panel both sides, missing fire blocking @ 3'' soil stack both sides, front door still missing straps @ entry on both sides. | |||
| LATH /BRICK FLASHING | 06/19/2006 | APPROVED | JMCGOWEN |
| ALL ROUGH | 06/16/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Improper wire straps on walls, L side - no water in tub to check drain, L side -missing firestop going down steps, repair firewall on front porch, missing strap tiedown within 12" on electrical box, L side - missing air return, box out L and R side washing machine returns,missing mullion clips on top of front windows - total house incomplete. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/31/2006 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/16/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: ALL THREADED RODS NEED TO BE TIGHTENED. PB 1AND2 NEED NAILS IN METAL PLATES.OFF RIDGE VENTS NEED TO BE BLOCKED CORRECTLY. NEED 2X6 COOLAR TIE JOIST NOT 2X4. BLOCKING MISSING LEFT BONUS RM. BETWEEN TRUSSES ON CMU. NEED TO ADD NAILS TO VALLY STRAPS TO WALL.CHECK BOTH SIDES.NOT READY. | |||
| FIREWALL FRAMING (DUPLEX) | 05/11/2006 | APPROVED | CMINI |
| LINTEL | 04/04/2006 | APPROVED | ARAYMOND |
| MONOLITHIC SLAB INSPECTION/SLAB | 03/09/2006 | APPROVED | JMCGOWEN |
| FIRST ROUGH PLUMBING INSPECTION | 02/28/2006 | APPROVED | ARAYMOND |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/07/2005 | 12/07/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | HOLD | 12/02/2005 | 12/05/2005 |
| Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. 1. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 2. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 3. Indicate how attic access will be constructed to comply with FRC Section R309.2. 4. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. 5. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0. | |||
| PLFM | COMPLETE | 11/10/2005 | 11/28/2005 |
| Note: Released By: CBENTLEY | |||
| PLFM | COMPLETE | 10/14/2005 | 10/14/2005 |
| Note: Released By: CBENTLEY Held By: CBENTLEY 56 Farmsworth Dr. Provide elevation certificate. If the home is in an "A" with base flood elevation the certificate should indicated the top of bottom floor at 1 ft above the base flood elevation. If the "A" zone does not have a base flood elevation determination than the certificate should indicate that the top of bottom floor is 2 ft. above highest adjacent grade. Received a survey showing that the property is outside the special flood hazard area. | |||
| SW1 | COMPLETE | 10/10/2005 | 10/10/2005 |
| Note: Released By: WKINELL | |||
| ZON | HOLD | 10/06/2005 | 10/13/2005 |
| Note: Held By: HHERKERT hold for ARC meeting 10-14-05 | |||
| ZON | COMPLETE | 10/14/2005 | |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤444.00 | 09/21/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 09/21/2006 |
| REINSPECTION FEE | ¤40.00 | 09/21/2006 |
| REINSPECTION FEE | ¤40.00 | 09/21/2006 |
| REINSPECTION FEE | ¤40.00 | 09/21/2006 |
| REINSPECTION FEE | ¤40.00 | 09/21/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤7,200.00 | 01/06/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/06/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤6,497.02 | 01/06/2006 |
| ADMIN FEE | ¤20.00 | 01/06/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 01/06/2006 |
| BUILDING CODE ADMIN FUND | ¤24.10 | 01/06/2006 |
| ELECTRIC FEE | ¤236.40 | 01/06/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤346.94 | 01/06/2006 |
| MECHANICAL FEE | ¤236.40 | 01/06/2006 |
| PERMIT FEE | ¤1,341.60 | 01/06/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤2,241.82 | 01/06/2006 |
| PLAN CHECK FEE | ¤137.60 | 01/06/2006 |
| PLUMBING FEE | ¤236.40 | 01/06/2006 |
| RADON FEE | ¤24.10 | 01/06/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤19,391.38 |