I want to search for...

Permit #2005100118

Permit Details

Status: COED

Parcel Id: 07-11-31-7009-00110-0180
CONDITIONED SPACE: 3354 sqft
GARAGE: 1094 sqft
OPENED PORCH (WITH ROOF) : 220 sqft
OPENED PORCH (WITH ROOF) : 152 sqft
Total Square Footage: 4820 sqft
Block: 11
Subdivision: -
Job Phone: (386)447-8680
Location Address: 56 FARMSWORTH DR
Type: DU - DUPLEX
Issue Date: 01/06/2006
NOC: RECORDED
Applicant name: MICHAEL LEO BRANIFF
Owner: RIVER CITY HOMES & DEVELOPMENT CORP.

Address

145 CYPRESS POINT PKWY UNIT 105

PALM COAST, FL 32164

Lot: 18
Contracted Stated Job Value: ¤192,800.00
Job Description: DUPLEX
Type: CN

Contractor

RIVER CITY HOMES
Status Location Address State License Number Phone
CANCEL

12058 SAN JOSE BLVD #804

Jacksonville, FL 32223

CGC062728 (Exp: 08/31/2012) 904-260-9009

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 09/20/2006 FINAL APPROVED JGIBSON
UTILITY COMPANY FINAL 09/19/2006 APPROVED MBACON
Note: THIS IS A REINSPECTION
UTILITY COMPANY FINAL 09/18/2006 Disapproved - NO FEE CBOEHME
Note: FAILED, CLEAN OUT HOLDING WATER THIS IS A REINSPECTION
UTILITY COMPANY FINAL 09/15/2006 Disapproved - NO FEE JSHEVLIN
Note: FAILED, CLEAN OUT HAS STANDING WATER
RESIDENTIAL EARLY POWER 09/14/2006 APPROVED LHITES
UTILITY COMPANY FINAL 09/13/2006 Disapproved - NO FEE JSHEVLIN
Note: FAILED, SEWER CLEAN OUT DUG UP AND EXPOSE HOLE FILLED WITH WATER CONTRACTOR MAKE REPAIR
STORMWATER FINAL INSPECTION 09/08/2006 APPROVED - AS NOTED DRANDALL
Note: 43 sf road damage
DRIVEWAY 08/08/2006 APPROVED DRANDALL
Note: THIS IS A REINSPECTION
DRIVEWAY 08/04/2006 Disapproved -FEE REQUIRED DRANDALL
Note: drainage is right to left as per swale sheet, right culvert pipe flows left to right, incorrect flow.....left culvert pipe is level, not correct pitch.....cut road edge at 90* not at a 45*.....need permit box accessible at time of inspection
INSULATION INSPECTION 06/26/2006 APPROVED JGIBSON
ALL ROUGH 06/22/2006 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
ALL ROUGH 06/21/2006 Disapproved -FEE REQUIRED JGIBSON
Note: Still missing straps @ panel 12'' above panel both sides, missing fire blocking @ 3'' soil stack both sides, front door still missing straps @ entry on both sides.
LATH /BRICK FLASHING 06/19/2006 APPROVED JMCGOWEN
ALL ROUGH 06/16/2006 Disapproved -FEE REQUIRED JGIBSON
Note: Improper wire straps on walls, L side - no water in tub to check drain, L side -missing firestop going down steps, repair firewall on front porch, missing strap tiedown within 12" on electrical box, L side - missing air return, box out L and R side washing machine returns,missing mullion clips on top of front windows - total house incomplete.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 05/31/2006 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 05/16/2006 Disapproved -FEE REQUIRED CMINI
Note: ALL THREADED RODS NEED TO BE TIGHTENED. PB 1AND2 NEED NAILS IN METAL PLATES.OFF RIDGE VENTS NEED TO BE BLOCKED CORRECTLY. NEED 2X6 COOLAR TIE JOIST NOT 2X4. BLOCKING MISSING LEFT BONUS RM. BETWEEN TRUSSES ON CMU. NEED TO ADD NAILS TO VALLY STRAPS TO WALL.CHECK BOTH SIDES.NOT READY.
FIREWALL FRAMING (DUPLEX) 05/11/2006 APPROVED CMINI
LINTEL 04/04/2006 APPROVED ARAYMOND
MONOLITHIC SLAB INSPECTION/SLAB 03/09/2006 APPROVED JMCGOWEN
FIRST ROUGH PLUMBING INSPECTION 02/28/2006 APPROVED ARAYMOND

Review History

Department Status Date In Date Out
BLD COMPLETE 12/07/2005 12/07/2005
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 12/02/2005 12/05/2005
Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. 1. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 2. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 3. Indicate how attic access will be constructed to comply with FRC Section R309.2. 4. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. 5. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0.
PLFM COMPLETE 11/10/2005 11/28/2005
Note: Released By: CBENTLEY
PLFM COMPLETE 10/14/2005 10/14/2005
Note: Released By: CBENTLEY Held By: CBENTLEY 56 Farmsworth Dr. Provide elevation certificate. If the home is in an "A" with base flood elevation the certificate should indicated the top of bottom floor at 1 ft above the base flood elevation. If the "A" zone does not have a base flood elevation determination than the certificate should indicate that the top of bottom floor is 2 ft. above highest adjacent grade. Received a survey showing that the property is outside the special flood hazard area.
SW1 COMPLETE 10/10/2005 10/10/2005
Note: Released By: WKINELL
ZON HOLD 10/06/2005 10/13/2005
Note: Held By: HHERKERT hold for ARC meeting 10-14-05
ZON COMPLETE 10/14/2005
Note: Released By: HHERKERT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤444.00 09/21/2006
EARLY POWER INSPECTION ¤40.00 09/21/2006
REINSPECTION FEE ¤40.00 09/21/2006
REINSPECTION FEE ¤40.00 09/21/2006
REINSPECTION FEE ¤40.00 09/21/2006
REINSPECTION FEE ¤40.00 09/21/2006
SCHOOL BOARD IMPACT FEE RES ¤7,200.00 01/06/2006
STORM WATER PERMIT FEES ¤80.00 01/06/2006
TRANS IMPACT FEE 4 - PER UNIT ¤6,497.02 01/06/2006
ADMIN FEE ¤20.00 01/06/2006
ARC HOUSE REVIEW ¤125.00 01/06/2006
BUILDING CODE ADMIN FUND ¤24.10 01/06/2006
ELECTRIC FEE ¤236.40 01/06/2006
FIRE RES IMPACT FEE 4-1-05 ¤346.94 01/06/2006
MECHANICAL FEE ¤236.40 01/06/2006
PERMIT FEE ¤1,341.60 01/06/2006
PARKS IMPACT FEE 11-2-04 ¤2,241.82 01/06/2006
PLAN CHECK FEE ¤137.60 01/06/2006
PLUMBING FEE ¤236.40 01/06/2006
RADON FEE ¤24.10 01/06/2006
Fees Total Due: ¤0.00 Total Paid: ¤19,391.38