I want to search for...
Permit #2005100144
Permit Details
Status: COED
| Parcel Id: 07-11-31-7064-00240-0020 |
| CONDITIONED SPACE: 1755 sqft |
| GARAGE: 398 sqft |
| OPENED PORCH (WITH ROOF) : 70 sqft |
| PATIO/DECK (NO ROOF) : 140 sqft |
| Total Square Footage: 2363 sqft |
| Block: 0024 |
| Subdivision: - |
| Job Phone: (386)756-4114 |
| Location Address: 11 LLOSEE CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/09/2005 |
| NOC: RECORDED |
| Applicant name: WAYNE LAWRENCE ADAMS |
| Owner: ADAMS HOMES OF NORTHWEST FLORIDA, INC. |
|
Address 3000 GULF BREEZE PARKWAY GULF BREEZE, FL 33127 |
| Lot: 020 |
| Contracted Stated Job Value: ¤134,953.00 |
| Job Description: SINGLE FAMILY HOME |
| Type: CN |
Contractor
ADAMS HOMES OF NW FLORIDA INC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1101 Gulf Breeze Parkway Suite 229 Gulf Breeze, FL 32561 |
CBC043518 (Exp: 08/31/2014) | (386)254-5081 | (386)252-8284 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 05/02/2006 | FINAL APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 04/27/2006 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Mast boot not installed properly | |||
| ENGINEERING FINAL | 04/25/2006 | APPROVED | GLALIMA |
| STORMWATER FINAL INSPECTION | 04/13/2006 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: 22 s.f. road damages can not have more than 3/4 inch lip end of driveway bring black top up | |||
| ENGINEERING FINAL | 04/05/2006 | CANCELLED BY INSPECTOR | LAPTEKAR |
| Note: canno schedule this inspection...no approved final surveys on file | |||
| UTILITY COMPANY FINAL | 03/30/2006 | APPROVED | RANDRADE |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 03/14/2006 | Disapproved - NO FEE | RANDRADE |
| Note: FAILED, NEEDS PIT AND METER (WATER) | |||
| PRE DRIVEWAY | 03/06/2006 | APPROVED | DSCHRAGER |
| RESIDENTIAL EARLY POWER | 03/01/2006 | APPROVED | JGIBSON |
| INSULATION INSPECTION | 01/31/2006 | APPROVED | JGIBSON |
| ALL ROUGH | 01/26/2006 | APPROVED | DROCKWELL |
| ALL ROUGH | 01/25/2006 | CANCELLED BY INSPECTOR | DROCKWELL |
| LATH /BRICK FLASHING | 01/20/2006 | APPROVED | DROCKWELL |
| EXTERIOR WALL SHEATHING/SHEAR WALL | 01/18/2006 | APPROVED | JGIBSON |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/18/2006 | APPROVED | JGIBSON |
| TEMPORARY POLE | 01/05/2006 | APPROVED | DROCKWELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 12/29/2005 | APPROVED | DROCKWELL |
| FIRST ROUGH PLUMBING INSPECTION | 12/27/2005 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 11/07/2005 | 11/08/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | HOLD | 10/26/2005 | 10/26/2005 |
| Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. 1. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. (Modify note #4 to list all door parameters required by code such as thickness and whether wood or metal, if metal state core material(s).) 2. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 3. Indicate how pull-down stair will be constructed to comply with FRC Section R309.2. (A pull down stair is not equivalent to ½" gypsum unless it is a rated assembly.) 4. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0. | |||
| BLD | HOLD | 10/14/2005 | 10/19/2005 |
| Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. 1. Update all General Notes, Specifications and other notes to reference to the current code version and sections. The current code version is the 2004 Florida Building Code - Residential (FRC 2004). 2. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 3. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. | |||
| SW1 | COMPLETE | 10/07/2005 | 10/12/2005 |
| Note: Released By: WKINELL | |||
| ZON | HOLD | 10/07/2005 | 10/13/2005 |
| Note: Held By: HHERKERT hold for ARC meeting 10-14-05 | |||
| ZON | COMPLETE | 10/14/2005 | |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 05/05/2006 |
| REINSPECTION FEE | ¤40.00 | 05/05/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 05/05/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 11/09/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 11/09/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 11/09/2005 |
| ADMIN FEE | ¤20.00 | 11/09/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 11/09/2005 |
| BUILDING CODE ADMIN FUND | ¤11.82 | 11/09/2005 |
| ELECTRIC FEE | ¤133.20 | 11/09/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 11/09/2005 |
| MECHANICAL FEE | ¤133.20 | 11/09/2005 |
| PERMIT FEE | ¤670.80 | 11/09/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 11/09/2005 |
| PLAN CHECK FEE | ¤68.80 | 11/09/2005 |
| PLUMBING FEE | ¤133.20 | 11/09/2005 |
| RADON FEE | ¤11.82 | 11/09/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,645.73 |