Permit #2005100149

Permit Details

Status: COED

Parcel Id: 07-11-31-7031-00410-0100
CONDITIONED SPACE: 2395 sqft
GARAGE: 549 sqft
OPENED PORCH (WITH ROOF) : 423 sqft
OPENED PORCH (WITH ROOF) : 52 sqft
Total Square Footage: 3419 sqft
Block: 0041
Subdivision: -
Job Phone: (386)851-7940
Location Address: 55 RICHMOND DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/11/2006
NOC: RECORDED
Applicant name: CRAIG JON SCHMAUSS
Owner: MERCEDES HOMES, INC.

Address

775 HARLEY STRICKLAND BLVD #110

ORANGE CITY, FL 32763

Lot: 100
Contracted Stated Job Value: ¤226,990.00
Job Description: SINGLE FAMILY
Type: CN

Contractor

MERCEDES HOMES INC.
Status Location Address State License Number Phone Fax
CANCEL

12001 SCIENCE DRIVE #160

ORLANDO, FL 32826

CGC1510145 (Exp: 08/31/2012) (407)272-5591 (407)282-1563

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 07/28/2006 FINAL APPROVED JHINDMAN
RESIDENTIAL EARLY POWER 07/26/2006 APPROVED PGALLMANN
STORMWATER FINAL INSPECTION 07/25/2006 APPROVED GLALIMA
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 07/17/2006 Disapproved -FEE REQUIRED DRANDALL
Note: clean construction debris from adjacent property right side, clean trash from rear & left property line, cut grass to access final grade, remove rebar from left side of house 51 s.f. road damage
UTILITY COMPANY FINAL 07/05/2006 APPROVED MBACON
DRIVEWAY 05/25/2006 APPROVED GLALIMA
LATH /BRICK FLASHING 05/19/2006 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
LATH /BRICK FLASHING 05/17/2006 Disapproved -FEE REQUIRED JHINDMAN
Note: THIS IS A REINSPECTION improper wire laps per fbcr703.6
LATH /BRICK FLASHING 05/12/2006 Disapproved -FEE REQUIRED JHINDMAN
Note: improper laps of wire and paper, exposed osb
INSULATION INSPECTION 05/11/2006 APPROVED CMINI
ALL ROUGH 05/08/2006 APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
ALL ROUGH 04/11/2006 Disapproved -FEE REQUIRED JHINDMAN
Note: no water pressure
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/04/2006 APPROVED PGALLMANN
LINTEL 03/13/2006 APPROVED PGALLMANN
MONOLITHIC SLAB INSPECTION/SLAB 02/27/2006 APPROVED PGALLMANN
FIRST ROUGH PLUMBING INSPECTION 02/21/2006 APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
FIRST ROUGH PLUMBING INSPECTION 02/20/2006 CANCELLED BY APPLICANT JGIBSON

Review History

Department Status Date In Date Out
BLD COMPLETE 12/21/2005 12/22/2005
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 12/09/2005 12/13/2005
Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. 1. Indicate on the drawing(s) the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 2. Indicate whether attic access in garage will be a pull-down stair or a removable panel and indicate how access will be constructed to comply with FRC Section R309.2. 3. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. 4. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0. 5. Clarify notes on T1: a. Floor plan note #2 calls for a 16" bond beam and the wall sections only show an 8" bond beam. Clarify what is required. b. Notes for palm coast only #3 calls for (1) additional rebar in pre-cast lintels. This additional rebar is not shown on the details. Clarify what is required. c. Dowel rod repair note references Hilti C-100 which is no longer available. Please revise. 6. The P.C. lintel schedule values for gravity and uplift loads do not match those of Cast-Crete. Please revise. Also, based on wall sections it appears that all lintels will be an 8" filled lintel with 1 #5. If this is the case, please remove the other columns for 16, 20, 24; however if they are to apply clearly indicate an 8, 16, 20, or 24 for each lintel designation.
ZON COMPLETE 12/06/2005 12/09/2005
Note: Released By: HHERKERT
SW1 COMPLETE 10/07/2005 10/12/2005
Note: Released By: WKINELL
ZON HOLD 10/07/2005 10/20/2005
Note: Held By: DCHAUDOIN NEED CALUATIONS OF ROOF PITCH, PERCENTAGES OF 3.15/12 AND 6/12

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 07/31/2006
REINSPECTION FEE ¤40.00 07/31/2006
REINSPECTION FEE ¤40.00 07/31/2006
REINSPECTION FEE ¤40.00 07/31/2006
STORMWATER REINSPECTION FEE ¤35.00 07/31/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 01/11/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 01/11/2006
STORM WATER PERMIT FEES ¤80.00 01/11/2006
ADMIN FEE ¤20.00 01/11/2006
ARC HOUSE REVIEW ¤125.00 01/11/2006
BUILDING CODE ADMIN FUND ¤17.10 01/11/2006
ELECTRIC FEE ¤173.40 01/11/2006
FIRE RES IMPACT FEE 4-1-05 ¤173.47 01/11/2006
MECHANICAL FEE ¤173.40 01/11/2006
PERMIT FEE ¤932.10 01/11/2006
PARKS IMPACT FEE 11-2-04 ¤1,120.91 01/11/2006
PLAN CHECK FEE ¤95.60 01/11/2006
PLUMBING FEE ¤173.40 01/11/2006
RADON FEE ¤17.10 01/11/2006
Fees Total Due: ¤0.00 Total Paid: ¤10,144.99