Permit #2005100246

Permit Details

Status: COED

CONDITIONED SPACE: 3205 sqft
GARAGE: 502 sqft
GARAGE: 293 sqft
OPENED PORCH (WITH ROOF) : 338 sqft
PATIO/DECK (NO ROOF) : 238 sqft
Total Square Footage: 4576 sqft
Subdivision: 2070 - Grand Haven North Phase 1 @ Grand Haven
Job Phone: (386)672-3955
Location Address: 3 WATERVIEW DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/04/2006
NOC: RECORDED
Applicant name: JERRY JAMES COLUMBUS
Owner: DELMASTRO, JOSEPH &

Address

ARMSTRONG, JEAN M. H&W

MOUNT KISCO, NY 10549

Address

9 BRENTWOOD COURT

MOUNT KISCO, NY 10549

Lot: 33
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

DISCOVERY HOMES INC.
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

300 INTERCHANGE BLVD.

PORT ORANGE, FL 32129

SUITE B

ORMOND BEACH, FL 32174

CGC046483 (Exp: 09/30/2008) (386)672-3955 (386)672-6958

Sub Contractors

LARRY MILTON HISS
Status Location Address State License Number Phone Fax
CANCEL

1315 A LPGA BLVD

Holly Hill, FL 32117

CAC032450 (Exp: 08/31/2018) (386) 672-8688 (386)238-8688
THOMAS WALTER ALBANO
Status Location Address State License Number Phone Fax
INACTIVE

P. O. BOX 352075

Palm Coast, FL 32135

CFC045991 (Exp: 08/31/2024) 386-437-2795 (386)437-2781
GREGORY A HAGEMAN
Status Location Address State License Number Phone
ACTIVE

545 Parque Drive

Ormond Beach, FL 32174

CCC021394 (Exp: 08/31/2026) (386) 672-2821
GLEN STEWART COLE
Status Location Address State License Number Phone Fax
HOLD

P. O. Box 1677

Palm Coast, FL 32136

EC0002522 (Exp: 08/31/2010) (386) 437-4364 (386)437-0412

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 04/27/2007 FINAL APPROVED JGIBSON
STORMWATER FINAL INSPECTION 04/26/2007 APPROVED GLALIMA
UTILITY COMPANY FINAL 04/24/2007 APPROVED TSCHWEERS
Note: THIS IS A REINSPECTION
UTILITY COMPANY FINAL 03/21/2007 Disapproved - NO FEE TSCHWEERS
Note: FAILED NO SOD DOWN OR FINAL GRADE
LATH /BRICK FLASHING 10/09/2006 APPROVED JGIBSON
ENGINEERING FINAL 09/22/2006 CANCELLED BY INSPECTOR LAPTEKAR
Note: this cannot be scheduled .....no final surveys on file...
INSULATION INSPECTION 09/12/2006 APPROVED JGIBSON
ALL ROUGH 09/06/2006 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
ALL ROUGH 09/05/2006 CANCELLED BY APPLICANT JGIBSON
Note: Canceled by contractor.
ALL ROUGH 09/01/2006 CANCELLED BY APPLICANT JGIBSON
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/29/2006 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/09/2006 Disapproved -FEE REQUIRED JGIBSON
Note: See previous notice on 6-2-06 for revisions and floor connection to LVL BEAMS ON STRAPS.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 06/12/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: THIS IS A REINSPECTION all revisions must be approved by building dept. Items from previous list are incomplete.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 06/02/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: need revision for first to second floor straps. need fastening schedule for lvl s. need to check bearing changes on floor trusses # f10, f5, and the bearing and load points on f8. not ready, incomplete list.
RESIDENTIAL EARLY POWER 05/26/2006 APPROVED RMARVEL
LINTEL 05/15/2006 APPROVED CMINI
MONOLITHIC SLAB INSPECTION/SLAB 04/19/2006 APPROVED JMCGOWEN
FIRST ROUGH PLUMBING INSPECTION 04/12/2006 APPROVED JMCGOWEN

Review History

Department Status Date In Date Out
BLD COMPLETE 12/11/2006 12/12/2006
Note: Released By: CCOTE Approved for Release. Review by Fred R. REVISION: Revised energy calcs.
BLD COMPLETE 08/23/2006 08/24/2006
Note: Released By: CCOTE Approved for Release. REVISION: LVL beam sheets BM1 & BM2.
BLD COMPLETE 03/16/2006 03/30/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 03/01/2006 03/01/2006
Note: Held By: CCOTE The City has received your response to previous comments however the following items were not addressed or need further clarification in order to complete the Building Permit Application plan review. 1. Beam sizing sheets were submitted but were not signed and sealed by an architect or engineer. Please add beam size/type information to a signed and sealed drawing or submit new sizing sheets that are signed and sealed. 2. Provide information for bond beam. 3. Provide lintel information indicating size and reinforcing. Ideally this would be added to window and door schedule with a column for this. Example: "8F16-1B/1T". In addition add all masonry openings.
BLD HOLD 01/11/2006 01/13/2006
Note: Held By: CCOTE The City received the responses to the previous comments; however the following items must be submitted in order to complete the Building Permit Application plan review. 1. Provide beam sizes for BM1, BM2 and BM3. Indicate connectors to be used at each end. These must be on a signed and sealed drawing and shall include connectors to be used. 2. Provide information for bond beam. 3. Provide interior bearing wall detail. 4. Provide lintel information indicating size and reinforcing. Ideally this would be added to window and door schedule with a column for this. Example: "8F16-1B/1T". In addition add all masonry openings. 5. Provide header sizes for all openings in 2nd floor wood framed exterior walls and 1st floor bearing walls. 6. Update gas riser diagram to indicate pipe material and size for underground pipe length from tank to regulator. 7. The framing layout from ALLSTAR had loading that does not meet code requirements. It only stated a 10psf for the BC Live load when the attic storage area must be 20psf. In addition, the mechanical unit will be in attic and there must be a not indicating this additional load on the framing layout.
BLD HOLD 10/20/2005 10/28/2005
Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. CITY OF PALM COAST o 2 COMMERCE BLVD o PALM COAST, FL 32164 PHONE: 386-986-3780 o FAX: 386-986-3781 1. Update all General Notes, Specifications, Truss package, Bennett design statement, and other notes to reference to the current code version and sections. The current code version is the 2004 Florida Building Code - Residential (FRC 2004). Only some of the notes on the drawings have been updated to the current code. 2. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 3. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 4. Indicate locations of attic access for upper roof section. 5. Indicate how access panel in garage will be constructed to comply with FRC Section R309.2. (A pull down stair is not equivalent to ½" gypsum unless it is a rated assembly.) 6. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. 7. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0. 8. The ceiling height over the toilet in the Powder Room does not comply with FRC R305.1 exception 4 that states a minimum 6'-8" ceiling height is required over fixtures. 9. Provide a 2nd floor framing layout. 10. Provide beam sizes for BM1, BM2 and 2nd floor porch beam. Indicate connectors to be used at each end. 11. Provide information for bond beam. 12. Provide interior bearing wall detail. 13. Provide a bond beam transition detail. 14. Provide lintel information indicating size and reinforcing. Ideally this would be added to window and door schedule with a column for this. Example: "8F16-1B/1T". In addition add all masonry openings. 15. Provide header sizes for all openings in 2nd floor wood framed exterior walls and 1st floor bearing walls. Include connectors/headers/fasteners, king/jack studs. 16. Provide information regarding filled cells. Indicate reinforcing size & overlaps as well as required locations and maximum spacing. 17. Provide gas riser diagram indicating pipe lengths, material, type and equipment BTU's. Also, provide propane tank size and location.
URB COMPLETE 10/18/2005 10/20/2005
Note: Released By: CGOEWEY Held By: CGOEWEY 10/20/05 (CB) PLEASE DO NOT PLANT LIVE OAKS NEAR ROAD. SUGGEST PLANTING OAKS IN BACK AND CREPE MYRTLES UP FRONT
SW1 COMPLETE 10/12/2005 11/04/2005
Note: Released By: LAPTEKAR
ZON COMPLETE 10/12/2005 10/18/2005
Note: Released By: HHERKERT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 04/30/2007
REINSPECTION FEE ¤40.00 04/30/2007
REINSPECTION FEE ¤40.00 04/30/2007
REINSPECTION FEE ¤40.00 04/30/2007
RENEW PERMIT FEES ¤40.00 04/30/2007
REVISION ¤40.00 04/30/2007
REVISION ¤40.00 04/30/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 04/04/2006
STORM WATER PERMIT FEES ¤80.00 04/04/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 04/04/2006
FIRE RES IMPACT FEE 4-1-05 ¤173.47 04/04/2006
MECHANICAL FEE ¤222.60 04/04/2006
PERMIT FEE ¤1,251.90 04/04/2006
PARKS IMPACT FEE 11-2-04 ¤1,120.91 04/04/2006
PLAN CHECK FEE ¤128.40 04/04/2006
PLUMBING FEE ¤222.60 04/04/2006
RADON FEE ¤22.88 04/04/2006
ADMIN FEE ¤20.00 04/04/2006
ARC HOUSE REVIEW ¤125.00 04/04/2006
BUILDING CODE ADMIN FUND ¤22.88 04/04/2006
ELECTRIC FEE ¤222.60 04/04/2006
Fees Total Due: ¤0.00 Total Paid: ¤10,741.75