Permit #2005100246
Permit Details
Status: COED
| CONDITIONED SPACE: 3205 sqft |
| GARAGE: 502 sqft |
| GARAGE: 293 sqft |
| OPENED PORCH (WITH ROOF) : 338 sqft |
| PATIO/DECK (NO ROOF) : 238 sqft |
| Total Square Footage: 4576 sqft |
| Subdivision: 2070 - Grand Haven North Phase 1 @ Grand Haven |
| Job Phone: (386)672-3955 |
| Location Address: 3 WATERVIEW DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/04/2006 |
| NOC: RECORDED |
| Applicant name: JERRY JAMES COLUMBUS |
| Owner: DELMASTRO, JOSEPH & |
|
Address ARMSTRONG, JEAN M. H&W MOUNT KISCO, NY 10549 |
|
Address 9 BRENTWOOD COURT MOUNT KISCO, NY 10549 |
| Lot: 33 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
DISCOVERY HOMES INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
300 INTERCHANGE BLVD. PORT ORANGE, FL 32129 |
SUITE B ORMOND BEACH, FL 32174 |
CGC046483 (Exp: 09/30/2008) | (386)672-3955 | (386)672-6958 |
Sub Contractors
LARRY MILTON HISS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1315 A LPGA BLVD Holly Hill, FL 32117 |
CAC032450 (Exp: 08/31/2018) | (386) 672-8688 | (386)238-8688 |
THOMAS WALTER ALBANO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P. O. BOX 352075 Palm Coast, FL 32135 |
CFC045991 (Exp: 08/31/2024) | 386-437-2795 | (386)437-2781 |
GREGORY A HAGEMAN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
545 Parque Drive Ormond Beach, FL 32174 |
CCC021394 (Exp: 08/31/2026) | (386) 672-2821 |
GLEN STEWART COLE
| Status | Location Address | State License Number | Phone | Fax |
| HOLD |
P. O. Box 1677 Palm Coast, FL 32136 |
EC0002522 (Exp: 08/31/2010) | (386) 437-4364 | (386)437-0412 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 04/27/2007 | FINAL APPROVED | JGIBSON |
| STORMWATER FINAL INSPECTION | 04/26/2007 | APPROVED | GLALIMA |
| UTILITY COMPANY FINAL | 04/24/2007 | APPROVED | TSCHWEERS |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 03/21/2007 | Disapproved - NO FEE | TSCHWEERS |
| Note: FAILED NO SOD DOWN OR FINAL GRADE | |||
| LATH /BRICK FLASHING | 10/09/2006 | APPROVED | JGIBSON |
| ENGINEERING FINAL | 09/22/2006 | CANCELLED BY INSPECTOR | LAPTEKAR |
| Note: this cannot be scheduled .....no final surveys on file... | |||
| INSULATION INSPECTION | 09/12/2006 | APPROVED | JGIBSON |
| ALL ROUGH | 09/06/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 09/05/2006 | CANCELLED BY APPLICANT | JGIBSON |
| Note: Canceled by contractor. | |||
| ALL ROUGH | 09/01/2006 | CANCELLED BY APPLICANT | JGIBSON |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/29/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/09/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: See previous notice on 6-2-06 for revisions and floor connection to LVL BEAMS ON STRAPS. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 06/12/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: THIS IS A REINSPECTION all revisions must be approved by building dept. Items from previous list are incomplete. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 06/02/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: need revision for first to second floor straps. need fastening schedule for lvl s. need to check bearing changes on floor trusses # f10, f5, and the bearing and load points on f8. not ready, incomplete list. | |||
| RESIDENTIAL EARLY POWER | 05/26/2006 | APPROVED | RMARVEL |
| LINTEL | 05/15/2006 | APPROVED | CMINI |
| MONOLITHIC SLAB INSPECTION/SLAB | 04/19/2006 | APPROVED | JMCGOWEN |
| FIRST ROUGH PLUMBING INSPECTION | 04/12/2006 | APPROVED | JMCGOWEN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/11/2006 | 12/12/2006 |
| Note: Released By: CCOTE Approved for Release. Review by Fred R. REVISION: Revised energy calcs. | |||
| BLD | COMPLETE | 08/23/2006 | 08/24/2006 |
| Note: Released By: CCOTE Approved for Release. REVISION: LVL beam sheets BM1 & BM2. | |||
| BLD | COMPLETE | 03/16/2006 | 03/30/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | HOLD | 03/01/2006 | 03/01/2006 |
| Note: Held By: CCOTE The City has received your response to previous comments however the following items were not addressed or need further clarification in order to complete the Building Permit Application plan review. 1. Beam sizing sheets were submitted but were not signed and sealed by an architect or engineer. Please add beam size/type information to a signed and sealed drawing or submit new sizing sheets that are signed and sealed. 2. Provide information for bond beam. 3. Provide lintel information indicating size and reinforcing. Ideally this would be added to window and door schedule with a column for this. Example: "8F16-1B/1T". In addition add all masonry openings. | |||
| BLD | HOLD | 01/11/2006 | 01/13/2006 |
| Note: Held By: CCOTE The City received the responses to the previous comments; however the following items must be submitted in order to complete the Building Permit Application plan review. 1. Provide beam sizes for BM1, BM2 and BM3. Indicate connectors to be used at each end. These must be on a signed and sealed drawing and shall include connectors to be used. 2. Provide information for bond beam. 3. Provide interior bearing wall detail. 4. Provide lintel information indicating size and reinforcing. Ideally this would be added to window and door schedule with a column for this. Example: "8F16-1B/1T". In addition add all masonry openings. 5. Provide header sizes for all openings in 2nd floor wood framed exterior walls and 1st floor bearing walls. 6. Update gas riser diagram to indicate pipe material and size for underground pipe length from tank to regulator. 7. The framing layout from ALLSTAR had loading that does not meet code requirements. It only stated a 10psf for the BC Live load when the attic storage area must be 20psf. In addition, the mechanical unit will be in attic and there must be a not indicating this additional load on the framing layout. | |||
| BLD | HOLD | 10/20/2005 | 10/28/2005 |
| Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. CITY OF PALM COAST o 2 COMMERCE BLVD o PALM COAST, FL 32164 PHONE: 386-986-3780 o FAX: 386-986-3781 1. Update all General Notes, Specifications, Truss package, Bennett design statement, and other notes to reference to the current code version and sections. The current code version is the 2004 Florida Building Code - Residential (FRC 2004). Only some of the notes on the drawings have been updated to the current code. 2. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 3. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 4. Indicate locations of attic access for upper roof section. 5. Indicate how access panel in garage will be constructed to comply with FRC Section R309.2. (A pull down stair is not equivalent to ½" gypsum unless it is a rated assembly.) 6. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. 7. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0. 8. The ceiling height over the toilet in the Powder Room does not comply with FRC R305.1 exception 4 that states a minimum 6'-8" ceiling height is required over fixtures. 9. Provide a 2nd floor framing layout. 10. Provide beam sizes for BM1, BM2 and 2nd floor porch beam. Indicate connectors to be used at each end. 11. Provide information for bond beam. 12. Provide interior bearing wall detail. 13. Provide a bond beam transition detail. 14. Provide lintel information indicating size and reinforcing. Ideally this would be added to window and door schedule with a column for this. Example: "8F16-1B/1T". In addition add all masonry openings. 15. Provide header sizes for all openings in 2nd floor wood framed exterior walls and 1st floor bearing walls. Include connectors/headers/fasteners, king/jack studs. 16. Provide information regarding filled cells. Indicate reinforcing size & overlaps as well as required locations and maximum spacing. 17. Provide gas riser diagram indicating pipe lengths, material, type and equipment BTU's. Also, provide propane tank size and location. | |||
| URB | COMPLETE | 10/18/2005 | 10/20/2005 |
| Note: Released By: CGOEWEY Held By: CGOEWEY 10/20/05 (CB) PLEASE DO NOT PLANT LIVE OAKS NEAR ROAD. SUGGEST PLANTING OAKS IN BACK AND CREPE MYRTLES UP FRONT | |||
| SW1 | COMPLETE | 10/12/2005 | 11/04/2005 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 10/12/2005 | 10/18/2005 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 04/30/2007 |
| REINSPECTION FEE | ¤40.00 | 04/30/2007 |
| REINSPECTION FEE | ¤40.00 | 04/30/2007 |
| REINSPECTION FEE | ¤40.00 | 04/30/2007 |
| RENEW PERMIT FEES | ¤40.00 | 04/30/2007 |
| REVISION | ¤40.00 | 04/30/2007 |
| REVISION | ¤40.00 | 04/30/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 04/04/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/04/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 04/04/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 04/04/2006 |
| MECHANICAL FEE | ¤222.60 | 04/04/2006 |
| PERMIT FEE | ¤1,251.90 | 04/04/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 04/04/2006 |
| PLAN CHECK FEE | ¤128.40 | 04/04/2006 |
| PLUMBING FEE | ¤222.60 | 04/04/2006 |
| RADON FEE | ¤22.88 | 04/04/2006 |
| ADMIN FEE | ¤20.00 | 04/04/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 04/04/2006 |
| BUILDING CODE ADMIN FUND | ¤22.88 | 04/04/2006 |
| ELECTRIC FEE | ¤222.60 | 04/04/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,741.75 |