I want to search for...
Permit #2005100301
Permit Details
Status: COED
| Parcel Id: 07-11-31-7013-00180-0010 |
| CONDITIONED SPACE: 3155 sqft |
| GARAGE: 688 sqft |
| OPENED PORCH (WITH ROOF) : 227 sqft |
| OPENED PORCH (WITH ROOF) : 78 sqft |
| Total Square Footage: 4148 sqft |
| Block: 0018 |
| Subdivision: - |
| Job Phone: (386) 445-7156 |
| Location Address: 89 BRUNETT LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/16/2005 |
| NOC: RECORDED |
| Applicant name: RICHARD L TAYLOR |
| Owner: MASTERPIECE HOMES |
|
Address 4721 E MOODY BLVD BUNNELL, FL 32110 |
| Lot: 010 |
| Contracted Stated Job Value: ¤162,713.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
Masterpiece Homes Inc. (Residential Contractor)
| Status | Location Address | Mailing Address | Phone | Fax |
| CANCEL |
4721 E MOODY BLVD BUNNELL, FL 32110 |
SUITE 504 BUNNELL, FL 32110 |
(386) 445-7156 | (386)445-7975 |
Sub Contractors
GLEN STEWART COLE
| Status | Location Address | State License Number | Phone | Fax |
| HOLD |
P. O. Box 1677 Palm Coast, FL 32136 |
EC0002522 (Exp: 08/31/2010) | (386) 437-4364 | (386)437-0412 |
MICHAEL DAVID CLARK
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Box 918 Bunnell, FL 32110 |
CAC044867 (Exp: 09/30/2008) | (386) 437-2001 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
MILLARD K KELLER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
313 S. VOLUSIA AVENUE DELAND, FL 32724 |
CCC1325778 (Exp: 08/31/2010) | (386) 774-9961 | (386)774-2388 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 05/23/2006 | FINAL APPROVED | ARITTER |
| STORMWATER FINAL INSPECTION | 05/16/2006 | APPROVED | DSCHRAGER |
| UTILITY COMPANY FINAL | 05/10/2006 | APPROVED | RANDRADE |
| PRE DRIVEWAY | 04/27/2006 | APPROVED | BFCHAMBERLAIN |
| LATH /BRICK FLASHING | 04/19/2006 | APPROVED | MMOORE |
| INSULATION INSPECTION | 04/10/2006 | APPROVED | MMOORE |
| ALL ROUGH | 04/03/2006 | APPROVED | ARITTER |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/09/2006 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/07/2006 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: NOT READY. PARTIAL LIST FOLLOWS: 1) MISSING TOP SHEER SUPPORT / BRIDGING AT GABLE END TRUSSES. AT PRESENT HELD WITH ROOF SHEATHING NAILS ONLY. PROVIDE APPROVED ENGINEER'S DETAIL SHOWING SHEER BRACING FOR TOP CORD OF GABLE END TRUSSES. 2) ONE T05 ROOF TRUSS, AT RIGHT SIDE OF GARAGE, IS TWISTED AT BOND BEAM. 3) SHEATHING ON GABLE END TRUSS T04 IS NOT NAILED 24" ON CENTER. 4) INSUFFICIENT BEARING UNDER LVL AT RIGHT REAR CORNER OF GARAGE. 5) FIRST FLOOR: INSUFFICIENT CORNER POST, LEFT SIDE OF STAIRS, SUPPORTING ONE SIDE OF WELL FLOOR TRUSS. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/02/2006 | APPROVED - AS NOTED | JLEVRAULT |
| Note: THIS IS A REINSPECTION CHANGE HEADER STRAPS TO LSTA24 PER PLAN...........ONE PIECE. CHECK AT ALL ROUGH. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/27/2006 | Disapproved -FEE REQUIRED | ARITTER |
| Note: plans missing | |||
| LINTEL | 02/08/2006 | APPROVED | JLEVRAULT |
| MONOLITHIC SLAB INSPECTION/SLAB | 01/25/2006 | APPROVED | JLEVRAULT |
| FIRST ROUGH PLUMBING INSPECTION | 01/20/2006 | APPROVED | MMOORE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 11/07/2005 | 11/08/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | HOLD | 10/21/2005 | 10/26/2005 |
| Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. 1. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 2. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and 2nd floor living space. Reference FRC Section R309.2. 3. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. 4. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0. | |||
| SW1 | COMPLETE | 10/13/2005 | 10/18/2005 |
| Note: Released By: LAPTEKAR | |||
| ZON | HOLD | 10/13/2005 | 10/17/2005 |
| Note: Held By: HHERKERT hold for ARC meeting 10-21-05 | |||
| ZON | COMPLETE | 10/21/2005 | |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 05/24/2006 |
| REINSPECTION FEE | ¤40.00 | 05/24/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 11/16/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 11/16/2005 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 11/16/2005 |
| ADMIN FEE | ¤20.00 | 11/16/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 11/16/2005 |
| BUILDING CODE ADMIN FUND | ¤20.74 | 11/16/2005 |
| ELECTRIC FEE | ¤214.20 | 11/16/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 11/16/2005 |
| MECHANICAL FEE | ¤214.20 | 11/16/2005 |
| PERMIT FEE | ¤1,197.30 | 11/16/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 11/16/2005 |
| PLAN CHECK FEE | ¤122.80 | 11/16/2005 |
| PLUMBING FEE | ¤214.20 | 11/16/2005 |
| RADON FEE | ¤20.74 | 11/16/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,452.07 |