I want to search for...
Permit #2005100577
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-00460-0070 |
| CONDITIONED SPACE: 2048 sqft |
| GARAGE: 610 sqft |
| OPENED PORCH (WITH ROOF) : 83 sqft |
| OPENED PORCH (WITH ROOF) : 236 sqft |
| Total Square Footage: 2977 sqft |
| Block: 0046 |
| Subdivision: - |
| Job Phone: (386) 445-7001 |
| Location Address: 60 LANCELOT DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/15/2005 |
| NOC: RECORDED |
| Applicant name: RICHARD M. ANDERSON |
| Owner: ISAAC, RUBY & DENNIS H&W |
|
Address 1602 UNION STREET APT 1E BROOKLYN, NY 11213 |
| Lot: 070 |
| Contracted Stated Job Value: ¤181,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
PALM WEST HOME BUILDERS, INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 Florida Park Drive North Palm Coast, FL 32137 |
CRC054633 (Exp: 08/31/2026) | (386) 445-7001 | (386)446-5941 |
Sub Contractors
JOHN S SMITH
| Status | Location Address | State License Number |
| CANCEL |
P. O. BOX 1160 Bunnell, FL 32110 |
ER0007785 (Exp: 08/31/2015) |
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
THOMAS WALTER ALBANO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P. O. BOX 352075 Palm Coast, FL 32135 |
CFC045991 (Exp: 08/31/2024) | 386-437-2795 | (386)437-2781 |
STEPHEN M RENDE
| Status | Location Address | State License Number | Phone |
| CANCEL |
22 ALAMANDA DRIVE ORMOND, FL 32176 |
CCC058058 (Exp: 08/31/2020) | 386-439-7156 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 07/13/2006 | FINAL APPROVED | MMOORE |
| STORMWATER FINAL INSPECTION | 06/29/2006 | APPROVED - AS NOTED | BFCHAMBERLAIN |
| Note: 10 s.f. road damage......$180 | |||
| UTILITY COMPANY FINAL | 06/23/2006 | APPROVED | TSCHWEERS |
| INSULATION INSPECTION | 06/22/2006 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION I SCHEDULED AN INSULATION INSPECTION TODAY, AND APPROVED IT AS PER JOE L-- JM | |||
| DRIVEWAY | 06/09/2006 | APPROVED | BFCHAMBERLAIN |
| RESIDENTIAL EARLY POWER | 05/24/2006 | APPROVED | RMARVEL |
| Note: secure the box for the water heater. FYI shower light in master bath needs a shower trim. | |||
| INSULATION INSPECTION | 03/27/2006 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: REMOVE RETURN AIR DUCT FROM KITCHEN. | |||
| ALL ROUGH | 03/24/2006 | APPROVED | MMOORE |
| ALL ROUGH | 03/23/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: EXPOSE GROUNDS AT METER ...OK TO INSULATE | |||
| LATH /BRICK FLASHING | 02/22/2006 | APPROVED | MMOORE |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/06/2006 | APPROVED | JLEVRAULT |
| LINTEL | 01/20/2006 | APPROVED | MMOORE |
| MONOLITHIC SLAB INSPECTION/SLAB | 01/09/2006 | APPROVED | MMOORE |
| TEMPORARY POLE | 01/09/2006 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 01/06/2006 | APPROVED | MMOORE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/09/2005 | 12/13/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| ZON | COMPLETE | 12/09/2005 | 12/09/2005 |
| Note: Released By: HHERKERT | |||
| ZON | HOLD | 12/02/2005 | 12/02/2005 |
| Note: Held By: HHERKERT new site plan required to include addition to rear of house | |||
| BLD | HOLD | 10/28/2005 | 11/03/2005 |
| Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. 1. The drawings reference a code section that does not exist in the current code version. The current code version is the 2004 Florida Building Code - Residential (FRC 2004). Indicate reference to the current code version on the drawings. 2. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 3. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 4. Indicate how attic access in garage will be constructed to comply with FRC Section R309.2. 5. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. | |||
| SW1 | COMPLETE | 10/25/2005 | 11/01/2005 |
| Note: Released By: LAPTEKAR | |||
| ZON | HOLD | 10/25/2005 | 10/26/2005 |
| Note: Held By: DCHAUDOIN SCHEDULED FOR ARC MEETING FRIDAY, NOVEMBER 28, 2005 | |||
| ZON | COMPLETE | 10/28/2005 | |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤180.00 | 07/14/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 07/14/2006 |
| REINSPECTION FEE | ¤40.00 | 07/14/2006 |
| REINSPECTION FEE | ¤40.00 | 07/14/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 12/15/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/15/2005 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 12/15/2005 |
| ADMIN FEE | ¤20.00 | 12/15/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 12/15/2005 |
| BUILDING CODE ADMIN FUND | ¤14.89 | 12/15/2005 |
| ELECTRIC FEE | ¤155.40 | 12/15/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 12/15/2005 |
| MECHANICAL FEE | ¤155.40 | 12/15/2005 |
| PERMIT FEE | ¤815.10 | 12/15/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 12/15/2005 |
| PLAN CHECK FEE | ¤83.60 | 12/15/2005 |
| PLUMBING FEE | ¤155.40 | 12/15/2005 |
| RADON FEE | ¤14.89 | 12/15/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,062.57 |