I want to search for...

Permit #2005100605

Permit Details

Status: COED

Parcel Id: 07-11-31-7010-00230-0320
CONDITIONED SPACE: 1820 sqft
GARAGE: 504 sqft
OPENED PORCH (WITH ROOF) : 194 sqft
OPENED PORCH (WITH ROOF) : 62 sqft
Total Square Footage: 2580 sqft
Block: 0023
Subdivision: -
Job Phone: (386)445-7343
Location Address: 89 FELWOOD LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/18/2005
NOC: RECORDED
Applicant name: BURTON ROBERT BERMAN
Owner: SIMOES, JAMIE & IRENE H&W

Address

68 FAIRBANKS LANE

PALM COAST, FL 32137

Lot: 320
Contracted Stated Job Value: ¤160,000.00
Job Description: RESIDENTIAL SINGLE FAMILY HOME
Type: CN

Contractor

PALM COAST HOMES & DEVELOPMENT CORP.
Status Location Address State License Number Phone
CANCEL

138 PALM COAST PARKWAY NE # 348

PALM COAST, FL 32137

CRC1326612 (Exp: 08/31/2012) (386)445-7343

Sub Contractors

MICHAEL DAVID CLARK
Status Location Address State License Number Phone
CANCEL

P. O. Box 918

Bunnell, FL 32110

CAC044867 (Exp: 09/30/2008) (386) 437-2001
MARTIN JOHN EVANS
Status Location Address State License Number
ACTIVE

14 FORT CAROLINE CT

BUNNELL, FL 32110

CFC057676 (Exp: 08/31/2026)
KURT A UMBACH
Status Location Address State License Number Phone Fax
HOLD

110 Foster Lane

Palm Coast, FL 32137

EC13003356 (Exp: 08/31/2020) (386) 446-3616 (386)446-3548

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 03/12/2007 FINAL APPROVED JMCGOWEN
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 03/09/2007 CANCELLED BY APPLICANT JMCGOWEN
FINAL COMPLETE BUILDING INSPECTION 03/08/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: NEED TO LABEL PANEL.NEED TO MOVE DISCONNECT FROM BEHIND A/C CONDENSOR.
STORMWATER FINAL INSPECTION 03/07/2007 APPROVED - AS NOTED DRANDALL
Note: THIS IS A REINSPECTION 33 sq ft road $364
STORMWATER FINAL INSPECTION 03/06/2007 Disapproved -FEE REQUIRED DRANDALL
Note: THIS IS A REINSPECTION 33 sf road damage.....seed & straw all exposed earth on rear & right side adj. property.....clean out culvert ends
STORMWATER FINAL INSPECTION 03/05/2007 Disapproved -FEE REQUIRED DRANDALL
Note: THIS IS A REINSPECTION seed & straw all exposed earth on left, rear, right sideadj. property.....pick up all trash from construction workers lunches, bottles, cans, papers, bags, ect,from left, rear, & right side adj. property.....clean out sand from culvert pipe ends.....33 sf road
STORMWATER FINAL INSPECTION 03/01/2007 Disapproved -FEE REQUIRED DRANDALL
Note: THIS IS A REINSPECTION previous items not done.....can not use seed & straw in city right of way.....33 sf road damage remove trash and debris from vacant lots
STORMWATER FINAL INSPECTION 02/27/2007 Disapproved -FEE REQUIRED DRANDALL
Note: place sod in adj. property swale on left side, all exposed earth 15' in from road edge.....seed & straw all exposed earth on left, rear, & right adj. property.....remove all trash from left, rear, & right adj. property, pallots, bottles, cans, papers, all construction debris.....33 sf road damage $364.00, clean out culvert ends
UTILITY COMPANY FINAL 02/27/2007 APPROVED TSCHWEERS
DRIVEWAY 09/20/2006 APPROVED DRANDALL
INSULATION INSPECTION 05/31/2006 APPROVED CMINI
LATH /BRICK FLASHING 05/31/2006 APPROVED CMINI
ALL ROUGH 05/24/2006 APPROVED - AS NOTED JMCGOWEN
Note: THIS IS A REINSPECTION fire stop missing at arch area, need drier duct boxed out and fire stoped
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 05/22/2006 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 05/19/2006 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION.GAGLE END STILL NOT PER PLAN. NEED SIMPSOM L30 CLIPS ON X BRACING.BEARING WALL STILL NOT COMPLETE.NOT READY
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 05/18/2006 CANCELLED BY APPLICANT CMINI
Note: THIS IS A REINSPECTION
ALL ROUGH 05/12/2006 Disapproved -FEE REQUIRED JGIBSON
Note: Roof sheathing has not passed inspection yet, truss R02 missing strap 3 point bearing truss , box out around dryer vent, mullion clips not arch windows, remove covers to GFCI in garage for inspection, electric not straped 12'' above panel box.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 02/28/2006 Disapproved -FEE REQUIRED ARAYMOND
Note: provide engineering for overhang at gable or block every 24", no l braces or t braces at gableend, x bracing incomplete, bearing wall incomplete, sheathing and cells ok
LINTEL 02/09/2006 APPROVED JMCGOWEN
Note: THIS IS A REINSPECTION
LINTEL 02/06/2006 Disapproved -FEE REQUIRED ARAYMOND
Note: Vertical steel span left side garage exceeds 8ft.Add additional steel
LINTEL 02/01/2006 Disapproved -FEE REQUIRED ARAYMOND
Note: no approved plans on site
MONOLITHIC SLAB INSPECTION/SLAB 01/13/2006 APPROVED JMCGOWEN
FIRST ROUGH PLUMBING INSPECTION 01/09/2006 APPROVED ARAYMOND

Review History

Department Status Date In Date Out
BLD COMPLETE 11/14/2005 11/14/2005
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 11/01/2005 11/04/2005
Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. 1. Update all General Notes, Specifications, Truss package, and other notes to reference to the current code version and sections. The current code version is the 2004 Florida Building Code - Residential (FRC 2004). 2. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 3. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 4. Indicate how attic access will be constructed to comply with FRC Section R309.2. 5. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. 6. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0.
URB COMPLETE 10/28/2005 10/28/2005
Note: Released By: CGOEWEY
SW1 COMPLETE 10/26/2005 11/01/2005
Note: Released By: LAPTEKAR
ZON HOLD 10/26/2005 10/27/2005
Note: Held By: DCHAUDOIN NEED TREE SURVEY SHOWING WHERE TREES WILL BE PLANTING.
ZON COMPLETE 11/01/2005
Note: Released By: HHERKERT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤364.00 03/12/2007
REINSPECTION FEE ¤40.00 03/12/2007
REINSPECTION FEE ¤40.00 03/12/2007
REINSPECTION FEE ¤40.00 03/12/2007
REINSPECTION FEE ¤40.00 03/12/2007
REINSPECTION FEE ¤40.00 03/12/2007
REINSPECTION FEE ¤40.00 03/12/2007
STORMWATER REINSPECTION FEE ¤35.00 03/12/2007
STORMWATER REINSPECTION FEE ¤35.00 03/12/2007
STORMWATER REINSPECTION FEE ¤35.00 03/12/2007
STORMWATER REINSPECTION FEE ¤35.00 03/12/2007
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 11/18/2005
ADMIN FEE ¤20.00 11/18/2005
ARC HOUSE REVIEW ¤125.00 11/18/2005
BUILDING CODE ADMIN FUND ¤12.90 11/18/2005
ELECTRIC FEE ¤140.40 11/18/2005
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 11/18/2005
STORM WATER PERMIT FEES ¤80.00 11/18/2005
FIRE RES IMPACT FEE 4-1-05 ¤173.47 11/18/2005
MECHANICAL FEE ¤140.40 11/18/2005
PERMIT FEE ¤717.60 11/18/2005
PARKS IMPACT FEE 11-2-04 ¤1,120.91 11/18/2005
PLAN CHECK FEE ¤73.60 11/18/2005
PLUMBING FEE ¤140.40 11/18/2005
RADON FEE ¤12.90 11/18/2005
Fees Total Due: ¤0.00 Total Paid: ¤10,350.09