I want to search for...
Permit #2005100622
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-01360-0010 |
| CONDITIONED SPACE: 2560 sqft |
| GARAGE: 549 sqft |
| OPENED PORCH (WITH ROOF) : 340 sqft |
| OPENED PORCH (WITH ROOF) : 52 sqft |
| Total Square Footage: 3501 sqft |
| Block: 0136 |
| Subdivision: - |
| Job Phone: (386)851-7940 |
| Location Address: 88 LONDON DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/20/2006 |
| NOC: RECORDED |
| Applicant name: CRAIG JON SCHMAUSS |
| Owner: WARNANT SUZANNE (BARONNE) |
|
Address 33 AV DE LA PINEDE BRUSSELS BELGIUM:, 00000 |
| Lot: 010 |
| Contracted Stated Job Value: ¤234,000.00 |
| Job Description: RESIDENTIAL SINGLE FAMILY HOME |
| Type: CN |
Contractor
MERCEDES HOMES INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
12001 SCIENCE DRIVE #160 ORLANDO, FL 32826 |
CGC1510145 (Exp: 08/31/2012) | (407)272-5591 | (407)282-1563 |
Sub Contractors
STEVEN JAY SMITH
| Status | Location Address | State License Number | Phone |
| INACTIVE |
104 West Cedar Avenue Orange City, FL 32763 |
EC0001542 (Exp: 08/31/2022) | (386)775-7776 |
EDDIE T PALMATEER
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
2985 ENTERPRISE ROAD DEBARY, FL 32713 |
SUITE A DEBARY, FL 32713 |
CAC1813533 (Exp: 08/31/2024) | (386)668-8651 | (386)668-7758 |
KATRINA ELAINE RIEF-D'ERRICO
| Status | Location Address | State License Number | Phone |
| CANCEL |
157 BOULDER ROCK DR Palm Coast, FL 32137 |
CFC1425676 (Exp: 09/30/2008) | (386)437-4250 |
LISA MARIE STEINER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
12001 SCIENCE DRIVE #160 ORLANDO, FL 32826 |
CGC1510145 (Exp: 08/31/2012) | (407)272-5591 | (407)282-1563 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 05/26/2006 | FINAL APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 05/19/2006 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: TOO MUCH TO LIST - NOTICE WITH DETAILS OF NON COMPLIANCE LEFT IN BOX. | |||
| STORMWATER FINAL INSPECTION | 05/16/2006 | APPROVED | DSCHRAGER |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 05/11/2006 | APPROVED | RANDRADE |
| STORMWATER FINAL INSPECTION | 05/09/2006 | Disapproved -FEE REQUIRED | BFCHAMBERLAIN |
| Note: Remove dumpster | |||
| DRIVEWAY | 04/17/2006 | APPROVED | BFCHAMBERLAIN |
| LATH /BRICK FLASHING | 04/11/2006 | APPROVED | MMOORE |
| INSULATION INSPECTION | 04/10/2006 | APPROVED | ARITTER |
| ALL ROUGH | 04/06/2006 | APPROVED | MMOORE |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/22/2006 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/20/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: THIS IS A REINSPECTION 1. #9 FROM LAST NON-COMPLIANCE-LAP PLATE AT NOOK WINDOW/ NOT DONE / OR RUN STRAP ACROSS CORNER 2. #6 FROM LAST NON-COMPLIANCE--TAOCONS TO BE 12" O.C. TOP AND SIDES/ EXPOSE TAPCONS | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/15/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. GROUT TRUSSES WITH STONELESS GROUT 2. LINTEL STRAP OVER M. SHOWER MISSED TRUSS 3. 2-PLY HG65T M. BATH AND JACK TRUSS NEXT TO IT/ THE STRAPS AREN'T NAILED-OFF 4. END HANGERS AT DECK/ LOSE AND MISSING NUTS 5. HANGER / END OF HG65T/ LOSE NUT 6. NEED TO SEE ATTACHMENT OF FRAME-OUT AT DECK FOR SLIDING DOOR 7. VAPOR BARRIER ALL TRUSSES OVER CONCRETE 8. GARAGE BEARING WALL FROM INSIDE KITCHEN AT RED MARKS ADD STUDS 9. NOOK WINDOW HEADERS/ INCORRECT FRAMING/ TOP PLATES MISSING/ NOT TIED TOGETHER AT CORNERS/ NOT STRAPPED PER PLAN 10. GR22P 2-PLY AT SLIDER WALL NOT DRILLEDR EPOXEED/ LOSE IN HOLE/ CHECK FOR CORRECT BOLT DIAMETER 11. TRUSS T-15 AT 2-PLY GR22P CALLS FOR HANGER THD210 | |||
| LINTEL | 02/27/2006 | APPROVED | MMOORE |
| MONOLITHIC SLAB INSPECTION/SLAB | 02/09/2006 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 02/07/2006 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| FIRST ROUGH PLUMBING INSPECTION | 02/03/2006 | CANCELLED BY APPLICANT | MMOORE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/18/2006 | 01/19/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | HOLD | 01/05/2006 | 01/10/2006 |
| Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. 1. Update all General Notes, Specifications and other notes to reference to the current code version and sections. The current code version is the 2004 Florida Building Code - Residential (FRC 2004). Not all drawing notes refer to the new code version. 2. Indicate on the drawing(s) the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 3. Indicate how access will be constructed to comply with FRC Section R309.2. 4. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. 5. Clarify notes on T1: a. Floor plan note #2 calls for a 16" bond beam and the wall sections only show an 8" bond beam. Clarify what is required. b. Notes for palm coast only #3 call for (1) additional rebar in pre-cast lintels. This additional rebar is not shown on the details. Clarify what is required. c. Dowel rod repair note references Hilti C-100 which is no longer available. Please revise. 6. The P.C. lintel schedule values for gravity and uplift loads do not match those of Cast-Crete. Please revise. Also, based on wall sections it appears that all lintels will be an 8" filled lintel with 1 #5. If this is the case, please remove the other columns for 16, 20, 24; however if they are to apply clearly indicate either an 8, 16, 20, or 24 for each lintel designation. | |||
| PLFM | COMPLETE | 01/03/2006 | 01/03/2006 |
| Note: Released By: CBENTLEY received survey showing that property is in a flood zone C. | |||
| PLFM | COMPLETE | 10/27/2005 | 11/23/2005 |
| Note: Released By: MWALLENBERG Held By: CBENTLEY Need elevation certificate Talked to applicant As requested from CBentley, FLM, research flood zone determination, area is determined to be in Flood Zone 'C'. | |||
| SW1 | COMPLETE | 10/26/2005 | 11/02/2005 |
| Note: Released By: LAPTEKAR corner lot...driveway flairs are 60' and 59' from intersection | |||
| ZON | COMPLETE | 10/26/2005 | 10/27/2005 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 05/31/2006 |
| REINSPECTION FEE | ¤40.00 | 05/31/2006 |
| REINSPECTION FEE | ¤40.00 | 05/31/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 05/31/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 01/20/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 01/20/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/20/2006 |
| ADMIN FEE | ¤20.00 | 01/20/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 01/20/2006 |
| BUILDING CODE ADMIN FUND | ¤17.51 | 01/20/2006 |
| ELECTRIC FEE | ¤180.60 | 01/20/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 01/20/2006 |
| MECHANICAL FEE | ¤180.60 | 01/20/2006 |
| PERMIT FEE | ¤978.90 | 01/20/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 01/20/2006 |
| PLAN CHECK FEE | ¤100.40 | 01/20/2006 |
| PLUMBING FEE | ¤180.60 | 01/20/2006 |
| RADON FEE | ¤17.51 | 01/20/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,179.01 |