I want to search for...

Permit #2005100622

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-01360-0010
CONDITIONED SPACE: 2560 sqft
GARAGE: 549 sqft
OPENED PORCH (WITH ROOF) : 340 sqft
OPENED PORCH (WITH ROOF) : 52 sqft
Total Square Footage: 3501 sqft
Block: 0136
Subdivision: -
Job Phone: (386)851-7940
Location Address: 88 LONDON DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/20/2006
NOC: RECORDED
Applicant name: CRAIG JON SCHMAUSS
Owner: WARNANT SUZANNE (BARONNE)

Address

33 AV DE LA PINEDE

BRUSSELS BELGIUM:, 00000

Lot: 010
Contracted Stated Job Value: ¤234,000.00
Job Description: RESIDENTIAL SINGLE FAMILY HOME
Type: CN

Contractor

MERCEDES HOMES INC.
Status Location Address State License Number Phone Fax
CANCEL

12001 SCIENCE DRIVE #160

ORLANDO, FL 32826

CGC1510145 (Exp: 08/31/2012) (407)272-5591 (407)282-1563

Sub Contractors

STEVEN JAY SMITH
Status Location Address State License Number Phone
INACTIVE

104 West Cedar Avenue

Orange City, FL 32763

EC0001542 (Exp: 08/31/2022) (386)775-7776
EDDIE T PALMATEER
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

2985 ENTERPRISE ROAD

DEBARY, FL 32713

SUITE A

DEBARY, FL 32713

CAC1813533 (Exp: 08/31/2024) (386)668-8651 (386)668-7758
KATRINA ELAINE RIEF-D'ERRICO
Status Location Address State License Number Phone
CANCEL

157 BOULDER ROCK DR

Palm Coast, FL 32137

CFC1425676 (Exp: 09/30/2008) (386)437-4250
LISA MARIE STEINER
Status Location Address State License Number Phone Fax
CANCEL

12001 SCIENCE DRIVE #160

ORLANDO, FL 32826

CGC1510145 (Exp: 08/31/2012) (407)272-5591 (407)282-1563

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 05/26/2006 FINAL APPROVED JLEVRAULT
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 05/19/2006 Disapproved -FEE REQUIRED JLEVRAULT
Note: TOO MUCH TO LIST - NOTICE WITH DETAILS OF NON COMPLIANCE LEFT IN BOX.
STORMWATER FINAL INSPECTION 05/16/2006 APPROVED DSCHRAGER
Note: THIS IS A REINSPECTION
UTILITY COMPANY FINAL 05/11/2006 APPROVED RANDRADE
STORMWATER FINAL INSPECTION 05/09/2006 Disapproved -FEE REQUIRED BFCHAMBERLAIN
Note: Remove dumpster
DRIVEWAY 04/17/2006 APPROVED BFCHAMBERLAIN
LATH /BRICK FLASHING 04/11/2006 APPROVED MMOORE
INSULATION INSPECTION 04/10/2006 APPROVED ARITTER
ALL ROUGH 04/06/2006 APPROVED MMOORE
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/22/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/20/2006 Disapproved -FEE REQUIRED MMOORE
Note: THIS IS A REINSPECTION 1. #9 FROM LAST NON-COMPLIANCE-LAP PLATE AT NOOK WINDOW/ NOT DONE / OR RUN STRAP ACROSS CORNER 2. #6 FROM LAST NON-COMPLIANCE--TAOCONS TO BE 12" O.C. TOP AND SIDES/ EXPOSE TAPCONS
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/15/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. GROUT TRUSSES WITH STONELESS GROUT 2. LINTEL STRAP OVER M. SHOWER MISSED TRUSS 3. 2-PLY HG65T M. BATH AND JACK TRUSS NEXT TO IT/ THE STRAPS AREN'T NAILED-OFF 4. END HANGERS AT DECK/ LOSE AND MISSING NUTS 5. HANGER / END OF HG65T/ LOSE NUT 6. NEED TO SEE ATTACHMENT OF FRAME-OUT AT DECK FOR SLIDING DOOR 7. VAPOR BARRIER ALL TRUSSES OVER CONCRETE 8. GARAGE BEARING WALL FROM INSIDE KITCHEN AT RED MARKS ADD STUDS 9. NOOK WINDOW HEADERS/ INCORRECT FRAMING/ TOP PLATES MISSING/ NOT TIED TOGETHER AT CORNERS/ NOT STRAPPED PER PLAN 10. GR22P 2-PLY AT SLIDER WALL NOT DRILLEDR EPOXEED/ LOSE IN HOLE/ CHECK FOR CORRECT BOLT DIAMETER 11. TRUSS T-15 AT 2-PLY GR22P CALLS FOR HANGER THD210
LINTEL 02/27/2006 APPROVED MMOORE
MONOLITHIC SLAB INSPECTION/SLAB 02/09/2006 APPROVED MMOORE
FIRST ROUGH PLUMBING INSPECTION 02/07/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
FIRST ROUGH PLUMBING INSPECTION 02/03/2006 CANCELLED BY APPLICANT MMOORE

Review History

Department Status Date In Date Out
BLD COMPLETE 01/18/2006 01/19/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 01/05/2006 01/10/2006
Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. 1. Update all General Notes, Specifications and other notes to reference to the current code version and sections. The current code version is the 2004 Florida Building Code - Residential (FRC 2004). Not all drawing notes refer to the new code version. 2. Indicate on the drawing(s) the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 3. Indicate how access will be constructed to comply with FRC Section R309.2. 4. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. 5. Clarify notes on T1: a. Floor plan note #2 calls for a 16" bond beam and the wall sections only show an 8" bond beam. Clarify what is required. b. Notes for palm coast only #3 call for (1) additional rebar in pre-cast lintels. This additional rebar is not shown on the details. Clarify what is required. c. Dowel rod repair note references Hilti C-100 which is no longer available. Please revise. 6. The P.C. lintel schedule values for gravity and uplift loads do not match those of Cast-Crete. Please revise. Also, based on wall sections it appears that all lintels will be an 8" filled lintel with 1 #5. If this is the case, please remove the other columns for 16, 20, 24; however if they are to apply clearly indicate either an 8, 16, 20, or 24 for each lintel designation.
PLFM COMPLETE 01/03/2006 01/03/2006
Note: Released By: CBENTLEY received survey showing that property is in a flood zone C.
PLFM COMPLETE 10/27/2005 11/23/2005
Note: Released By: MWALLENBERG Held By: CBENTLEY Need elevation certificate Talked to applicant As requested from CBentley, FLM, research flood zone determination, area is determined to be in Flood Zone 'C'.
SW1 COMPLETE 10/26/2005 11/02/2005
Note: Released By: LAPTEKAR corner lot...driveway flairs are 60' and 59' from intersection
ZON COMPLETE 10/26/2005 10/27/2005
Note: Released By: HHERKERT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 05/31/2006
REINSPECTION FEE ¤40.00 05/31/2006
REINSPECTION FEE ¤40.00 05/31/2006
STORMWATER REINSPECTION FEE ¤35.00 05/31/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 01/20/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 01/20/2006
STORM WATER PERMIT FEES ¤80.00 01/20/2006
ADMIN FEE ¤20.00 01/20/2006
ARC HOUSE REVIEW ¤125.00 01/20/2006
BUILDING CODE ADMIN FUND ¤17.51 01/20/2006
ELECTRIC FEE ¤180.60 01/20/2006
FIRE RES IMPACT FEE 4-1-05 ¤173.47 01/20/2006
MECHANICAL FEE ¤180.60 01/20/2006
PERMIT FEE ¤978.90 01/20/2006
PARKS IMPACT FEE 11-2-04 ¤1,120.91 01/20/2006
PLAN CHECK FEE ¤100.40 01/20/2006
PLUMBING FEE ¤180.60 01/20/2006
RADON FEE ¤17.51 01/20/2006
Fees Total Due: ¤0.00 Total Paid: ¤10,179.01