I want to search for...
Permit #2005110020
Permit Details
Status: COED
| Parcel Id: 07-11-31-7035-00140-0010 |
| CONDITIONED SPACE: 2703 sqft |
| GARAGE: 526 sqft |
| OPENED PORCH (WITH ROOF) : 268 sqft |
| OPENED PORCH (WITH ROOF) : 56 sqft |
| Total Square Footage: 3553 sqft |
| Block: 0014 |
| Subdivision: - |
| Job Phone: (386)447-0836 |
| Location Address: 44 BURNING EMBER LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/20/2005 |
| NOC: RECORDED |
| Applicant name: ANTONIO AMARAL JR |
| Owner: THET, TIM N. |
|
Address 92 LONGMEADOW AVENU WARWICK, RI 02889 |
| Lot: 010 |
| Contracted Stated Job Value: ¤175,900.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
WORLD CLASS HOMES OF NE FLORIDA INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
13 UTILITY DR PALM COAST, FL 32137 |
RR282811317 (Exp: 08/31/2011) | (386)447-0836 | (386)447-7959 |
Sub Contractors
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 1009 BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2014) | (386) 931-2568 | 386-313-3445 |
THOMAS ALAN MOSE
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO BOX 1894 HOLLY HILL, FL 32117 |
CAC048082 (Exp: 08/31/2026) | 386-255-4545 | (386)252-4979 |
JAMES JOSEPH SAVNIK JR
| Status | Location Address | State License Number | Phone |
| CANCEL |
1120 COUNTY RD 305 BUNNELL, 32110 |
CPC057381 (Exp: 09/30/2008) | (386) 445-1253 |
ANTONIO JR AMARAL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
13 Utility Drive PALM COAST, FL 32137 |
CCC058004 (Exp: 08/31/2018) | (386)445-9393 | (386)446-0403 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 06/07/2006 | FINAL APPROVED | PGALLMANN |
| STORMWATER FINAL INSPECTION | 06/05/2006 | APPROVED | BFCHAMBERLAIN |
| RESIDENTIAL EARLY POWER | 05/30/2006 | APPROVED | RMARVEL |
| UTILITY COMPANY FINAL | 05/26/2006 | APPROVED | RANDRADE |
| Note: INSPECTOR WAS CHRIS BOEHME | |||
| PRE DRIVEWAY | 04/28/2006 | APPROVED | BFCHAMBERLAIN |
| INSULATION INSPECTION | 03/30/2006 | APPROVED | JLEVRAULT |
| ALL ROUGH | 03/24/2006 | APPROVED | JLEVRAULT |
| LATH /BRICK FLASHING | 03/17/2006 | APPROVED | JLEVRAULT |
| LATH /BRICK FLASHING | 03/16/2006 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: not ready | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/22/2006 | APPROVED | JLEVRAULT |
| LINTEL | 01/30/2006 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION 1. **********NOTE*************STUDY ROOM WALL WITH DOOR OPENING ADDED BACK INTO STRUCTURE. THIS WALL WAS NOT THERE AT THE FIRST LINTEL INSPECTION. AFTER A REVISION WAS REQUESTED FOR THE MISSING WALL THEY DECIDED TO ADD THE WALL PER PLAN. | |||
| LINTEL | 01/26/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: revision needed for removal of study room wall | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 01/25/2006 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 01/17/2006 | APPROVED | ARITTER |
| MONOLITHIC SLAB INSPECTION/SLAB | 01/13/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 13 DOWELS MISSING/ SEE SHEET #3 FOUNDATION PLAN | |||
| FIRST ROUGH PLUMBING INSPECTION | 01/11/2006 | APPROVED | JLEVRAULT |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/14/2005 | 12/15/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R. | |||
| BLD | HOLD | 11/10/2005 | 11/14/2005 |
| Note: Held By: FREODICA 1. Update all General Notes, Specifications and other notes to reference to the current code version and sections. The current code version is the 2004 Florida Building Code - Residential (FRC 2004). 2. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 3. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 4. Indicate whether attic access in garage will be a pull-down stair or a removable panel and indicate how access will be constructed to comply with FRC Section R309.2. 5. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0. 6. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. CITY OF PALM COAST o 2 COMMERCE BLVD o PALM COAST, FL 32164 PHONE: 386-986-3780 o FAX: 386-986-3781 | |||
| ZON | COMPLETE | 11/10/2005 | 11/10/2005 |
| Note: Released By: HHERKERT | |||
| SW1 | HOLD | 11/01/2005 | 11/10/2005 |
| Note: Held By: LAPTEKAR All permits as of 11/1/05 are required to submit 2 sealed topographical surveys...and proposed elevations for the grading plan. The side walk in the right of way will also need to show a mitered end culvert pipe in detail. | |||
| ZON | HOLD | 11/01/2005 | 11/08/2005 |
| Note: Held By: HHERKERT wing wall encroaches the 25' front/side setback | |||
| SW1 | HOLD | 12/14/2005 | |
| Note: Held By: LAPTEKAR Topo survey needs to have a permanent benchmark that is not a cap in the road and right of way needs to be amended to add sidewalk and side wallk detail. | |||
| SW1 | COMPLETE | 12/20/2005 | |
| Note: Released By: LAPTEKAR Benchmark is now a nail in the utility pole |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 06/08/2006 |
| REINSPECTION FEE | ¤40.00 | 06/08/2006 |
| REINSPECTION FEE | ¤40.00 | 06/08/2006 |
| REINSPECTION FEE | ¤40.00 | 06/08/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 12/20/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/20/2005 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 12/20/2005 |
| ADMIN FEE | ¤20.00 | 12/20/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 12/20/2005 |
| BUILDING CODE ADMIN FUND | ¤17.77 | 12/20/2005 |
| ELECTRIC FEE | ¤186.60 | 12/20/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 12/20/2005 |
| MECHANICAL FEE | ¤186.60 | 12/20/2005 |
| PERMIT FEE | ¤1,017.90 | 12/20/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 12/20/2005 |
| PLAN CHECK FEE | ¤104.40 | 12/20/2005 |
| PLUMBING FEE | ¤186.60 | 12/20/2005 |
| RADON FEE | ¤17.77 | 12/20/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,245.53 |