Permit #2005110029
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-00370-0090 |
| CONDITIONED SPACE: 2560 sqft |
| GARAGE: 549 sqft |
| OPENED PORCH (WITH ROOF) : 340 sqft |
| OPENED PORCH (WITH ROOF) : 52 sqft |
| Total Square Footage: 3501 sqft |
| Block: 0037 |
| Subdivision: - |
| Job Phone: (386)851-7940 |
| Location Address: 4 EASTMAN LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/21/2005 |
| NOC: RECORDED |
| Applicant name: CRAIG JON SCHMAUSS |
| Owner: MERCEDES HOMES |
|
Address 775 HARLEY STRICKLAND ORANGE CITY, FL 32763 |
| Lot: 090 |
| Contracted Stated Job Value: ¤238,990.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MERCEDES HOMES INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
12001 SCIENCE DRIVE #160 ORLANDO, FL 32826 |
CGC1510145 (Exp: 08/31/2012) | (407)272-5591 | (407)282-1563 |
Sub Contractors
STEVEN JAY SMITH
| Status | Location Address | State License Number | Phone |
| INACTIVE |
104 West Cedar Avenue Orange City, FL 32763 |
EC0001542 (Exp: 08/31/2022) | (386)775-7776 |
EDDIE T PALMATEER
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
2985 ENTERPRISE ROAD DEBARY, FL 32713 |
SUITE A DEBARY, FL 32713 |
CAC1813533 (Exp: 08/31/2024) | (386)668-8651 | (386)668-7758 |
KATRINA ELAINE RIEF-D'ERRICO
| Status | Location Address | State License Number | Phone |
| CANCEL |
157 BOULDER ROCK DR Palm Coast, FL 32137 |
CFC1425676 (Exp: 09/30/2008) | (386)437-4250 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 08/11/2006 | FINAL APPROVED | KSAMPICO |
| UTILITY COMPANY FINAL | 08/08/2006 | APPROVED | MBACON |
| STORMWATER FINAL INSPECTION | 08/07/2006 | APPROVED | BFCHAMBERLAIN |
| RESIDENTIAL EARLY POWER | 07/19/2006 | APPROVED | KSAMPICO |
| DRIVEWAY | 06/26/2006 | APPROVED | GLALIMA |
| LATH /BRICK FLASHING | 05/18/2006 | APPROVED | JGIBSON |
| INSULATION INSPECTION | 05/16/2006 | APPROVED | JGIBSON |
| ALL ROUGH | 05/11/2006 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 05/01/2006 | CANCELLED BY APPLICANT | JGIBSON |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/01/2006 | APPROVED | JGIBSON |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/29/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/20/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Missalighned straps, letter of repair on bond beam, blown out when weadge anchor was installed, guest bath room pre-cast has rebar exposed. | |||
| LINTEL | 03/07/2006 | APPROVED | JGIBSON |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 03/02/2006 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 02/14/2006 | APPROVED | JGIBSON |
| FIRST ROUGH PLUMBING INSPECTION | 02/10/2006 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 05/09/2006 | 05/09/2006 |
| Note: Released By: LWOODROME Revision: Bond beam repair | |||
| SW1 | COMPLETE | 12/20/2005 | 12/21/2005 |
| Note: Released By: LAPTEKAR recieved new topo with corrected benchmark | |||
| BLD | COMPLETE | 12/12/2005 | 12/14/2005 |
| Note: Released By: LWOODROME approved for release as noted on plan cover sheet. Review by FR | |||
| BLD | HOLD | 11/09/2005 | 11/14/2005 |
| Note: Held By: FREODICA 1. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 2. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 3. Indicate whether attic access in garage will be a pull-down stair or a removable panel and indicate how access will be constructed to comply with FRC Section R309.2. 4. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. 5. Clarify notes on sheet T1: a. Floor plan note #2 calls 16 " bond beam while details show 8" on sheet T3. b. Note #3 on Palm Coast Only calls for (1) additional rebar in pre-cast lintels but it is not shown on the details. c. Dowel rod repair note references Hilti C-100 which is no longer available. Please revise. 6. The precast lintel schedule values for gravity & uplift loads do not match those of Cast-Crete Catalog.Please revise. Please be specific on the type of precast lintel to be used for each window/door openings including garage door, and porch. Cross-out all pre-cast lintel types that do not apply to this project. CITY OF PALM COAST o 2 COMMERCE BLVD o PALM COAST, FL 32164 PHONE: 386-986-3780 o FAX: 386-986-3781 | |||
| SW1 | HOLD | 11/01/2005 | 11/07/2005 |
| Note: Held By: LAPTEKAR received lot grading plan and topo......12/6. | |||
| ZON | COMPLETE | 11/01/2005 | 11/09/2005 |
| Note: Released By: HHERKERT | |||
| SW1 | HOLD | 12/07/2005 | |
| Note: Held By: LAPTEKAR Released By: LAPTEKAR topographic survey needs to have a benchmark that easily identifiable and not a pavement nail in the road |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 08/14/2006 |
| REINSPECTION FEE | ¤40.00 | 08/14/2006 |
| REVISION | ¤40.00 | 08/14/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 12/21/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/21/2005 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 12/21/2005 |
| ADMIN FEE | ¤20.00 | 12/21/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 12/21/2005 |
| BUILDING CODE ADMIN FUND | ¤17.51 | 12/21/2005 |
| ELECTRIC FEE | ¤180.60 | 12/21/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 12/21/2005 |
| MECHANICAL FEE | ¤180.60 | 12/21/2005 |
| PERMIT FEE | ¤978.90 | 12/21/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 12/21/2005 |
| PLAN CHECK FEE | ¤100.40 | 12/21/2005 |
| PLUMBING FEE | ¤180.60 | 12/21/2005 |
| RADON FEE | ¤17.51 | 12/21/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,144.01 |