I want to search for...
Permit #2005110108
Permit Details
Status: COED
| Parcel Id: 07-11-31-7014-00070-0090 |
| CONDITIONED SPACE: 2424 sqft |
| GARAGE: 672 sqft |
| OPENED PORCH (WITH ROOF) : 336 sqft |
| OPENED PORCH (WITH ROOF) : 68 sqft |
| Total Square Footage: 3500 sqft |
| Block: 0007 |
| Subdivision: - |
| Job Phone: (386)447-4400 |
| Location Address: 6 CROSSWAY CT W |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/29/2005 |
| NOC: RECORDED |
| Applicant name: DAVID PAUL CROCKETT |
| Owner: PAPA, DOMINICK & KYUNG |
|
Address 1989 SWEET GUM DRIVE AVON, IN 46123 |
| Lot: 090 |
| Contracted Stated Job Value: ¤245,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
THE WATERSIDE GROUP, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
17-B BRELYN PLACE PALM COAST, FL 32137 |
RG0041345 (Exp: 08/31/2010) | (386)447-4400 | (386)447-5800 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
LARRY MILTON HISS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1315 A LPGA BLVD Holly Hill, FL 32117 |
CAC032450 (Exp: 08/31/2018) | (386) 672-8688 | (386)238-8688 |
MARTIN JOHN EVANS
| Status | Location Address | State License Number |
| ACTIVE |
14 FORT CAROLINE CT BUNNELL, FL 32110 |
CFC057676 (Exp: 08/31/2026) |
DAVID PAUL CROCKETT
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
17B BRELYN PLACE PALM COAST, FL 32137 |
RC0041394 (Exp: 08/31/2011) | (386)447-4400 | (386)447-5800 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 03/27/2007 | FINAL APPROVED | JMCGOWEN |
| Note: | |||
| FINAL COMPLETE BUILDING INSPECTION | 03/23/2007 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: LIGHTING MISSING FOR REAR EGRESS (PORCH AREA) | |||
| STORMWATER FINAL INSPECTION | 03/22/2007 | APPROVED | DRANDALL |
| Note: THIS IS A REINSPECTION | |||
| STORMWATER FINAL INSPECTION | 03/15/2007 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: right rear of house at property line, pvc pipe is broken, repair pvc pipe, regrade & resod same area.....9 sf road damage $172.00 | |||
| UTILITY COMPANY FINAL | 03/13/2007 | APPROVED | AGRAHAM |
| DRIVEWAY | 01/22/2007 | APPROVED | DRANDALL |
| LATH /BRICK FLASHING | 10/02/2006 | APPROVED | LHITES |
| INSULATION INSPECTION | 09/11/2006 | APPROVED | JGIBSON |
| ALL ROUGH | 09/05/2006 | APPROVED | ACOOPER |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/14/2006 | APPROVED | CMINI |
| LINTEL | 07/05/2006 | APPROVED | KSAMPICO |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 06/29/2006 | APPROVED - AS NOTED | LAPTEKAR |
| Note: May need to adjust lot grading plan to accommodate FFE | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 06/08/2006 | APPROVED | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 06/02/2006 | APPROVED | JMCGOWEN |
| TEMPORARY POLE | 03/07/2006 | CANCELLED BY INSPECTOR | ARAYMOND |
| Note: Already done | |||
| TEMPORARY POLE | 02/24/2006 | APPROVED | ARAYMOND |
| Note: called susan at 4:45 marga |
Review History
| Department | Status | Date In | Date Out |
| SW1 | CANCEL | 11/03/2006 | |
| Note: received new topo survey 11/3 | |||
| SW1 | HOLD | 09/22/2006 | 09/22/2006 |
| Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are different than we expected by +1.23ft. This is closer to NGVD 1929 than NAVD 1988. Please submit three signed sealed topographic surveys for this property showing corrected elevations. Note: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised. | |||
| BLD | COMPLETE | 07/21/2006 | 07/25/2006 |
| Note: Released By: LWOODROME Revision: Truss repair | |||
| BLD | COMPLETE | 07/06/2006 | 07/07/2006 |
| Note: Released By: CCOTE Approved for Release. Revision: Substitute threaded rod for SP1 &2 @ load bearing walls per engineer letter. | |||
| SW1 | HOLD | 12/07/2005 | 12/08/2005 |
| Note: Held By: LAPTEKAR Received the topographic survey...however the lot grading plan is missing....also all saltwater canal lots need a grade elevation profile. | |||
| BLD | COMPLETE | 12/01/2005 | 12/02/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | HOLD | 11/28/2005 | 11/29/2005 |
| Note: Held By: CCOTE Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. 1. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0. | |||
| BLD | HOLD | 11/10/2005 | 11/15/2005 |
| Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. 1. Update all General Notes, Specifications, Truss package, and other notes to reference to the current code version and sections. The current code version is the 2004 Florida Building Code - Residential (FRC 2004). 2. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 3. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 4. Indicate how attic access will be constructed to comply with FRC Section R309.2. 5. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. 6. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0. | |||
| SW1 | HOLD | 11/04/2005 | 11/17/2005 |
| Note: Held By: LAPTEKAR need sealed topo survey and lot proposed elevations on the lot grading plan | |||
| ZON | COMPLETE | 11/04/2005 | 11/10/2005 |
| Note: Released By: HHERKERT | |||
| SW1 | HOLD | 12/16/2005 | |
| Note: Held By: LAPTEKAR The lot grading plan still needs proposed elevations ...not just in the swale. | |||
| SW1 | COMPLETE | 12/27/2005 | |
| Note: Released By: LAPTEKAR |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 03/29/2007 |
| REVISION | ¤40.00 | 03/29/2007 |
| REVISION | ¤40.00 | 03/29/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 03/29/2007 |
| SW REVISION | ¤40.00 | 03/29/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 12/29/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 12/29/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/29/2005 |
| ADMIN FEE | ¤20.00 | 12/29/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 12/29/2005 |
| BUILDING CODE ADMIN FUND | ¤17.50 | 12/29/2005 |
| ELECTRIC FEE | ¤177.60 | 12/29/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 12/29/2005 |
| MECHANICAL FEE | ¤177.60 | 12/29/2005 |
| PERMIT FEE | ¤959.40 | 12/29/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 12/29/2005 |
| PLAN CHECK FEE | ¤98.40 | 12/29/2005 |
| PLUMBING FEE | ¤177.60 | 12/29/2005 |
| RADON FEE | ¤17.50 | 12/29/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,188.49 |