Permit #2005110298

Permit Details

Status: COED

Parcel Id: 15-11-31-2835-00000-0040
CONDITIONED SPACE: 3319 sqft
GARAGE: 502 sqft
OPENED PORCH (WITH ROOF) : 418 sqft
OPENED PORCH (WITH ROOF) : 228 sqft
OPENED PORCH (WITH ROOF) : 106 sqft
Total Square Footage: 4573 sqft
Block: 0000
Subdivision: 1075 - FRONT STREET @ GRAND HAVEN PH5
Job Phone: (386) 445-4408
Location Address: 81 FRONT ST
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/16/2005
NOC: RECORDED
Applicant name: PATRICK E KOLLAR
Owner: GRIFFITH THOMAS A &

Address

SHARON J H&W

SAN JOSE, CA 95120

Lot: 4
Contracted Stated Job Value: ¤300,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

RED CARPET CONSTRUCTION INC.
Status Location Address State License Number Phone Fax
ACTIVE

8A Market Place Court

Palm Coast, FL 32137

CRC017457 (Exp: 08/31/2026) (386) 445-4408 (386)446-2232

Sub Contractors

BEN K REIHL
Status Location Address State License Number Phone Fax
ACTIVE

605 MCINTOSH ROAD

Ormond Beach, 32174

EC0002867 (Exp: 08/31/2026) (386) 677-4464 386-673-4199
LARRY MILTON HISS
Status Location Address State License Number Phone Fax
CANCEL

1315 A LPGA BLVD

Holly Hill, FL 32117

CAC032450 (Exp: 08/31/2018) (386) 672-8688 (386)238-8688
GARY S WELBORN
Status Location Address State License Number Phone Fax
CANCEL

1709 North Nova Road

Holly Hill, FL 32117

CFC037140 (Exp: 08/31/2018) (386) 257-1172 (386)252-5979
BARRY D MARTIN
Status Location Address State License Number Phone Fax
CANCEL

1650 N STATE STREET

Bunnell, FL 32110

CCC033728 (Exp: 08/31/2020) (386) 437-7700 (386)437-7701

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 04/27/2007 FINAL APPROVED JGIBSON
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 03/30/2007 CANCELLED BY APPLICANT JGIBSON
STORMWATER FINAL INSPECTION 03/23/2007 APPROVED DRANDALL
UTILITY COMPANY FINAL 03/15/2007 APPROVED AGRAHAM
RESIDENTIAL EARLY POWER 02/09/2007 APPROVED RMARVEL
INSULATION INSPECTION 10/17/2006 APPROVED JGIBSON
ALL ROUGH 09/26/2006 APPROVED JGIBSON
LATH /BRICK FLASHING 09/21/2006 APPROVED LHITES
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/16/2006 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 07/13/2006 CANCELLED BY APPLICANT JGIBSON
LINTEL 05/09/2006 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
LINTEL 04/27/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: need revision showing steel form lintels, not to plan
FLOOD ZONE 'A' ELEVATION CERTIFICATE APPROVAL 04/26/2006 APPROVED CBENTLEY
MONOLITHIC SLAB INSPECTION/SLAB 03/30/2006 APPROVED JMCGOWEN
TEMPORARY POLE 03/30/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: temp. pole must be located so that power cords are not crossing other peoples property
FIRST ROUGH PLUMBING INSPECTION 03/20/2006 APPROVED JMCGOWEN

Review History

Department Status Date In Date Out
BLD COMPLETE 07/18/2006 07/18/2006
Note: Released By: CCOTE Approved for Release. Revision: Revised sheet A2 & A8. Connector changes, added post at 2nd floor porch.
BLD COMPLETE 05/02/2006 05/04/2006
Note: Released By: LWOODROME Revision: Lintel schedule
BLD REJECT 03/02/2006 03/07/2006
Note: Rejected By: CCOTE "Or equal" is not sufficient. Need to submit items to be considered as equals.
BLD COMPLETE 12/12/2005 12/13/2005
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD COMPLETE 12/07/2005 12/08/2005
Note: Released By: ECOYNE Held By: CCOTE The City received your comments regarding the previous remarks however the following items must be addressed/submitted in order to complete the Building Permit Application plan review. 1. Provide sizes of all Beams on a signed and sealed drawing. 2. Provide connectors for all beams on a signed and sealed drawing.
BLD COMPLETE 12/05/2005 12/05/2005
Note: Released By: ECOYNE Held By: CCOTE The City received your comments regarding the previous remarks however the following items must be addressed/submitted in order to complete the Building Permit Application plan review. 1. The drawings contain two interior bearing wall details, one on A7 and one on S1. They are different clarify if both are to be used and if so denote locations on plan. (Load bearing detail with no step-down on sheet A7 indicates anchor bolt spacing of 18" while the foundation plan indicates 21" anchor bolt spacing. Clarify what is required.) 2. Provide sizes of all Beams on a signed and sealed drawing. 3. Provide connectors for all beams on a signed and sealed drawing. 4. The 2nd floor plan has section marks that appear to be incorrect. Please revised and/or provide details. (Plan detail marks 5/A-2 & 6/A-2) 5. The floor plan indicates that all lintels will be 8F24-1B/1T however this will not work at all locations based on the elevations. Also the plan indicates some lintels such as L16, L11 but it the lintel schedule on S2 has several options for these. Please clearly indicate specific lintel types/sizes/reinforcing to be used all masonry openings. (There is not 24" between top of window and bond beam elevation)
BLD COMPLETE 11/29/2005 11/29/2005
Note: Released By: ECOYNE Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. The drawings contain two interior bearing wall details, one on A7 and one on S1. They are different clarify if both are to be used and if so denote locations on plan. 2. The drawings contain shear wall detail. Please identify where to be used. 3. Provide sizes of all Beams on a signed and sealed drawing. 4. Provide connectors for all beams on a signed and sealed drawing. 5. Provide wall section showing how exterior wall is attached at stair opening where no floor joists exist. 6. Provide a wall section showing how floor joists and 2nd floor framing is attached when floor joist is perpendicular to exterior wall. 7. Show floor framing members on framing plan for exterior floor structure. 8. The 2nd floor plan has section marks that appear to be incorrect. Please revised and/or provide details. 9. Revise detail 8 on A2 to show the support below (beam or wall) and how floor joists are connected to it. Preferably a beam since the wall section shows the floor joist to wall already. 10. Provide size of beam for 2nd floor balcony area that will support balcony roof. 11. Provide information for 2nd floor balcony posts. Include connection at base and at top. 12. Clarify stud sizes to be used for 2nd floor exterior wall. The section indicates 2x4 however the plan appears to show various widths. 13. Clarify bearing of floor framing members F06 & F07 at beam 5 since these members are higher than the beam. Will there be a bearing wall here? Clarify how uplift from upper roof is continuous to foundation. 14. The code references regarding amendments are incorrect. Please correct. 15. The floor plan indicates that all lintels will be 8F24-1B/1T however this will not work at all locations based on the elevations. Also the plan indicates some lintels such as L16, L11 but it the lintel schedule on S2 has several options for these. Please clearly indicate specific lintel types/sizes/reinforcing to be used all masonry openings. 16. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 17. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 18. Indicate how attic access will be constructed to comply with FRC Section R309.2. 19. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1.
URB COMPLETE 11/28/2005 11/29/2005
Note: Released By: ECOYNE Held By: CGOEWEY 11/29/05 (CG) NEED A TREE SURVEY
SW1 COMPLETE 11/15/2005 12/05/2005
Note: Released By: LAPTEKAR
ZON COMPLETE 11/15/2005 11/15/2005
Note: Released By: HHERKERT
PLFM COMPLETE 11/15/2005 11/23/2005
Note: Released By: CBENTLEY Held By: CBENTLEY 81 Front St Need Elevation Certificate
URB COMPLETE 11/29/2005
Note: Released By: CGOEWEY

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 04/27/2007
REINSPECTION FEE ¤40.00 04/27/2007
REINSPECTION FEE ¤40.00 04/27/2007
REVISION ¤40.00 04/27/2007
REVISION ¤40.00 04/27/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 12/16/2005
STORM WATER PERMIT FEES ¤80.00 12/16/2005
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 12/16/2005
ADMIN FEE ¤20.00 12/16/2005
BUILDING CODE ADMIN FUND ¤22.87 12/16/2005
ELECTRIC FEE ¤222.60 12/16/2005
FIRE RES IMPACT FEE 4-1-05 ¤173.47 12/16/2005
MECHANICAL FEE ¤222.60 12/16/2005
PERMIT FEE ¤1,251.90 12/16/2005
PARKS IMPACT FEE 11-2-04 ¤1,120.91 12/16/2005
PLAN CHECK FEE ¤128.40 12/16/2005
PLUMBING FEE ¤222.60 12/16/2005
RADON FEE ¤22.87 12/16/2005
Fees Total Due: ¤0.00 Total Paid: ¤10,536.73