I want to search for...
Permit #2005110298
Permit Details
Status: COED
| Parcel Id: 15-11-31-2835-00000-0040 |
| CONDITIONED SPACE: 3319 sqft |
| GARAGE: 502 sqft |
| OPENED PORCH (WITH ROOF) : 418 sqft |
| OPENED PORCH (WITH ROOF) : 228 sqft |
| OPENED PORCH (WITH ROOF) : 106 sqft |
| Total Square Footage: 4573 sqft |
| Block: 0000 |
| Subdivision: 1075 - FRONT STREET @ GRAND HAVEN PH5 |
| Job Phone: (386) 445-4408 |
| Location Address: 81 FRONT ST |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/16/2005 |
| NOC: RECORDED |
| Applicant name: PATRICK E KOLLAR |
| Owner: GRIFFITH THOMAS A & |
|
Address SHARON J H&W SAN JOSE, CA 95120 |
| Lot: 4 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
RED CARPET CONSTRUCTION INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
8A Market Place Court Palm Coast, FL 32137 |
CRC017457 (Exp: 08/31/2026) | (386) 445-4408 | (386)446-2232 |
Sub Contractors
BEN K REIHL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
605 MCINTOSH ROAD Ormond Beach, 32174 |
EC0002867 (Exp: 08/31/2026) | (386) 677-4464 | 386-673-4199 |
LARRY MILTON HISS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1315 A LPGA BLVD Holly Hill, FL 32117 |
CAC032450 (Exp: 08/31/2018) | (386) 672-8688 | (386)238-8688 |
GARY S WELBORN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1709 North Nova Road Holly Hill, FL 32117 |
CFC037140 (Exp: 08/31/2018) | (386) 257-1172 | (386)252-5979 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 04/27/2007 | FINAL APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 03/30/2007 | CANCELLED BY APPLICANT | JGIBSON |
| STORMWATER FINAL INSPECTION | 03/23/2007 | APPROVED | DRANDALL |
| UTILITY COMPANY FINAL | 03/15/2007 | APPROVED | AGRAHAM |
| RESIDENTIAL EARLY POWER | 02/09/2007 | APPROVED | RMARVEL |
| INSULATION INSPECTION | 10/17/2006 | APPROVED | JGIBSON |
| ALL ROUGH | 09/26/2006 | APPROVED | JGIBSON |
| LATH /BRICK FLASHING | 09/21/2006 | APPROVED | LHITES |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/16/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/13/2006 | CANCELLED BY APPLICANT | JGIBSON |
| LINTEL | 05/09/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 04/27/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: need revision showing steel form lintels, not to plan | |||
| FLOOD ZONE 'A' ELEVATION CERTIFICATE APPROVAL | 04/26/2006 | APPROVED | CBENTLEY |
| MONOLITHIC SLAB INSPECTION/SLAB | 03/30/2006 | APPROVED | JMCGOWEN |
| TEMPORARY POLE | 03/30/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: temp. pole must be located so that power cords are not crossing other peoples property | |||
| FIRST ROUGH PLUMBING INSPECTION | 03/20/2006 | APPROVED | JMCGOWEN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 07/18/2006 | 07/18/2006 |
| Note: Released By: CCOTE Approved for Release. Revision: Revised sheet A2 & A8. Connector changes, added post at 2nd floor porch. | |||
| BLD | COMPLETE | 05/02/2006 | 05/04/2006 |
| Note: Released By: LWOODROME Revision: Lintel schedule | |||
| BLD | REJECT | 03/02/2006 | 03/07/2006 |
| Note: Rejected By: CCOTE "Or equal" is not sufficient. Need to submit items to be considered as equals. | |||
| BLD | COMPLETE | 12/12/2005 | 12/13/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | COMPLETE | 12/07/2005 | 12/08/2005 |
| Note: Released By: ECOYNE Held By: CCOTE The City received your comments regarding the previous remarks however the following items must be addressed/submitted in order to complete the Building Permit Application plan review. 1. Provide sizes of all Beams on a signed and sealed drawing. 2. Provide connectors for all beams on a signed and sealed drawing. | |||
| BLD | COMPLETE | 12/05/2005 | 12/05/2005 |
| Note: Released By: ECOYNE Held By: CCOTE The City received your comments regarding the previous remarks however the following items must be addressed/submitted in order to complete the Building Permit Application plan review. 1. The drawings contain two interior bearing wall details, one on A7 and one on S1. They are different clarify if both are to be used and if so denote locations on plan. (Load bearing detail with no step-down on sheet A7 indicates anchor bolt spacing of 18" while the foundation plan indicates 21" anchor bolt spacing. Clarify what is required.) 2. Provide sizes of all Beams on a signed and sealed drawing. 3. Provide connectors for all beams on a signed and sealed drawing. 4. The 2nd floor plan has section marks that appear to be incorrect. Please revised and/or provide details. (Plan detail marks 5/A-2 & 6/A-2) 5. The floor plan indicates that all lintels will be 8F24-1B/1T however this will not work at all locations based on the elevations. Also the plan indicates some lintels such as L16, L11 but it the lintel schedule on S2 has several options for these. Please clearly indicate specific lintel types/sizes/reinforcing to be used all masonry openings. (There is not 24" between top of window and bond beam elevation) | |||
| BLD | COMPLETE | 11/29/2005 | 11/29/2005 |
| Note: Released By: ECOYNE Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. The drawings contain two interior bearing wall details, one on A7 and one on S1. They are different clarify if both are to be used and if so denote locations on plan. 2. The drawings contain shear wall detail. Please identify where to be used. 3. Provide sizes of all Beams on a signed and sealed drawing. 4. Provide connectors for all beams on a signed and sealed drawing. 5. Provide wall section showing how exterior wall is attached at stair opening where no floor joists exist. 6. Provide a wall section showing how floor joists and 2nd floor framing is attached when floor joist is perpendicular to exterior wall. 7. Show floor framing members on framing plan for exterior floor structure. 8. The 2nd floor plan has section marks that appear to be incorrect. Please revised and/or provide details. 9. Revise detail 8 on A2 to show the support below (beam or wall) and how floor joists are connected to it. Preferably a beam since the wall section shows the floor joist to wall already. 10. Provide size of beam for 2nd floor balcony area that will support balcony roof. 11. Provide information for 2nd floor balcony posts. Include connection at base and at top. 12. Clarify stud sizes to be used for 2nd floor exterior wall. The section indicates 2x4 however the plan appears to show various widths. 13. Clarify bearing of floor framing members F06 & F07 at beam 5 since these members are higher than the beam. Will there be a bearing wall here? Clarify how uplift from upper roof is continuous to foundation. 14. The code references regarding amendments are incorrect. Please correct. 15. The floor plan indicates that all lintels will be 8F24-1B/1T however this will not work at all locations based on the elevations. Also the plan indicates some lintels such as L16, L11 but it the lintel schedule on S2 has several options for these. Please clearly indicate specific lintel types/sizes/reinforcing to be used all masonry openings. 16. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 17. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 18. Indicate how attic access will be constructed to comply with FRC Section R309.2. 19. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. | |||
| URB | COMPLETE | 11/28/2005 | 11/29/2005 |
| Note: Released By: ECOYNE Held By: CGOEWEY 11/29/05 (CG) NEED A TREE SURVEY | |||
| SW1 | COMPLETE | 11/15/2005 | 12/05/2005 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 11/15/2005 | 11/15/2005 |
| Note: Released By: HHERKERT | |||
| PLFM | COMPLETE | 11/15/2005 | 11/23/2005 |
| Note: Released By: CBENTLEY Held By: CBENTLEY 81 Front St Need Elevation Certificate | |||
| URB | COMPLETE | 11/29/2005 | |
| Note: Released By: CGOEWEY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 04/27/2007 |
| REINSPECTION FEE | ¤40.00 | 04/27/2007 |
| REINSPECTION FEE | ¤40.00 | 04/27/2007 |
| REVISION | ¤40.00 | 04/27/2007 |
| REVISION | ¤40.00 | 04/27/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 12/16/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/16/2005 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 12/16/2005 |
| ADMIN FEE | ¤20.00 | 12/16/2005 |
| BUILDING CODE ADMIN FUND | ¤22.87 | 12/16/2005 |
| ELECTRIC FEE | ¤222.60 | 12/16/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 12/16/2005 |
| MECHANICAL FEE | ¤222.60 | 12/16/2005 |
| PERMIT FEE | ¤1,251.90 | 12/16/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 12/16/2005 |
| PLAN CHECK FEE | ¤128.40 | 12/16/2005 |
| PLUMBING FEE | ¤222.60 | 12/16/2005 |
| RADON FEE | ¤22.87 | 12/16/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,536.73 |