I want to search for...
Permit #2005110443
Permit Details
Status: COED
| Parcel Id: 07-11-31-7016-00040-1000 |
| CONDITIONED SPACE: 1808 sqft |
| GARAGE: 478 sqft |
| OPENED PORCH (WITH ROOF) : 280 sqft |
| OPENED PORCH (WITH ROOF) : 32 sqft |
| Total Square Footage: 2598 sqft |
| Block: 0004 |
| Subdivision: - |
| Job Phone: (386) 445-5239 |
| Location Address: 6 COCHRAN LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/19/2006 |
| NOC: RECORDED |
| Applicant name: MICHAEL W DILLARD |
| Owner: COLLINS, MARTIN |
|
Address 4 CLOVELAND COURT PALM COAST, FL 32137 |
| Lot: 000 |
| Contracted Stated Job Value: ¤184,900.00 |
| Job Description: RESIDENTIAL SINGLE FAMILY |
| Type: CN |
Contractor
DILLARD CONSTRUCTION LLC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 355007 PALM COAST, FL 32137 |
CGC1510399 (Exp: 09/30/2010) | 386-864-1320 | (386)986-3054 |
Sub Contractors
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
MARTIN JOHN EVANS
| Status | Location Address | State License Number |
| ACTIVE |
14 FORT CAROLINE CT BUNNELL, FL 32110 |
CFC057676 (Exp: 08/31/2026) |
MILLARD K KELLER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
313 S. VOLUSIA AVENUE DELAND, FL 32724 |
CCC1325778 (Exp: 08/31/2010) | (386) 774-9961 | (386)774-2388 |
RICHARD H SIMMONS JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P. O. Box 1963 Bunnell, FL 32110 |
ER0011613 (Exp: 08/31/2008) | (386) 437-0607 | (386)437-1847 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 12/14/2006 | FINAL APPROVED | RMARVEL |
| UTILITY COMPANY FINAL | 12/13/2006 | APPROVED | MBACON |
| STORMWATER FINAL INSPECTION | 12/12/2006 | APPROVED - AS NOTED | DRANDALL |
| Note: 49 sf road damage | |||
| RESIDENTIAL EARLY POWER | 12/04/2006 | APPROVED | LHITES |
| Note: DILLARD CALLED TO SCHEDULE AN EARLY POWER INSPECTION FOR 12/4/06 | |||
| DRIVEWAY | 10/25/2006 | APPROVED | DRANDALL |
| LATH /BRICK FLASHING | 09/28/2006 | APPROVED | CMINI |
| INSULATION INSPECTION | 09/08/2006 | APPROVED | LHITES |
| ALL ROUGH | 09/05/2006 | APPROVED | ACOOPER |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 08/30/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: All exterior walls need to be fire blocked @ top tuff-R insulation can not pass under fire blocking, no water pressure, juccuzzi tub must have dedicated circuit, pump motor not bonded to copper pipes. | |||
| ALL ROUGH | 08/28/2006 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: Wrong print. Unable to inspect. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/04/2006 | APPROVED | KSAMPICO |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/03/2006 | Disapproved -FEE REQUIRED | KSAMPICO |
| Note: Engineers revision letter on garage wall bolts needs approved by city. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/02/2006 | CANCELLED BY APPLICANT | KSAMPICO |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/31/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: finish straps in garage,T-15 trusses need to set on bearing wall at mid point header and bolts missing, fram to block conection not to plan, plate bolt washers need to be two inch as to plan, bolts and truss straps missing on garage wall detail ( only areas that plan calls for | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 07/10/2006 | APPROVED | WKINELL |
| LINTEL | 07/07/2006 | APPROVED | JGIBSON |
| MONOLITHIC SLAB INSPECTION/SLAB | 06/28/2006 | APPROVED | RMARVEL |
| FIRST ROUGH PLUMBING INSPECTION | 06/23/2006 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 08/02/2006 | 08/03/2006 |
| Note: Released By: LWOODROME Revision: Engineers letter Re; connectors at garage wall | |||
| BLD | HOLD | 12/22/2005 | 12/21/2005 |
| Note: Held By: FREODICA 1. Resubmitted energy calculations did not have the Passing Points. | |||
| BLD | COMPLETE | 12/22/2005 | 12/22/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R. | |||
| BLD | HOLD | 11/29/2005 | 11/29/2005 |
| Note: Held by: FREODICA 1. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 2. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 3. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. 4. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0. 5. Indicate whether attic access on garage will be a pull-down stair or a removable panel and indicate how access will be constructed to comply with FRC section R309.2. | |||
| URB | COMPLETE | 11/23/2005 | 11/28/2005 |
| Note: Released By: CBENNETT | |||
| SW1 | HOLD | 11/21/2005 | 12/08/2005 |
| Note: Held By: WKINELL No Lot Grading Plan submitted.... Need proposed elevations next to the existing elevations and also a grade elevation profile for a saltwater canal lot | |||
| ZON | COMPLETE | 11/21/2005 | 11/23/2005 |
| Note: Released By: HHERKERT | |||
| SW1 | COMPLETE | 02/16/2006 | |
| Note: Released By: LAPTEKAR |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤492.00 | 12/14/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 12/14/2006 |
| REINSPECTION FEE | ¤40.00 | 12/14/2006 |
| REINSPECTION FEE | ¤40.00 | 12/14/2006 |
| REINSPECTION FEE | ¤40.00 | 12/14/2006 |
| REINSPECTION FEE | ¤40.00 | 12/14/2006 |
| REVISION | ¤40.00 | 12/14/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 04/19/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/19/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 04/19/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 04/19/2006 |
| MECHANICAL FEE | ¤141.00 | 04/19/2006 |
| PERMIT FEE | ¤721.50 | 04/19/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 04/19/2006 |
| PLAN CHECK FEE | ¤74.00 | 04/19/2006 |
| PLUMBING FEE | ¤141.00 | 04/19/2006 |
| RADON FEE | ¤12.99 | 04/19/2006 |
| ADMIN FEE | ¤20.00 | 04/19/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 04/19/2006 |
| BUILDING CODE ADMIN FUND | ¤12.99 | 04/19/2006 |
| ELECTRIC FEE | ¤141.00 | 04/19/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,344.37 |