Permit #2005110568

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00240-0170
CONDITIONED SPACE: 3305 sqft
GARAGE: 534 sqft
OPENED PORCH (WITH ROOF) : 635 sqft
OPENED PORCH (WITH ROOF) : 91 sqft
Total Square Footage: 4565 sqft
Block: 00240
Subdivision: -
Job Phone: (386)445-7343
Location Address: 26 WHITTIER LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/21/2006
NOC: RECORDED
Applicant name: BURTON ROBERT BERMAN
Owner: REVOLUS JOSEPH & EDNIE

Address

26 VALENTINE PLACE

HEMPSTEAD, NY 11550

Lot: 0170
Contracted Stated Job Value: ¤325,000.00
Job Description: RESIDENTIAL SINGLE FAMILY HOME
Type: CN

Contractor

PALM COAST HOMES & DEVELOPMENT CORP.
Status Location Address State License Number Phone
CANCEL

138 PALM COAST PARKWAY NE # 348

PALM COAST, FL 32137

CRC1326612 (Exp: 08/31/2012) (386)445-7343

Sub Contractors

MICHAEL DAVID CLARK
Status Location Address State License Number Phone
CANCEL

P. O. Box 918

Bunnell, FL 32110

CAC044867 (Exp: 09/30/2008) (386) 437-2001
MARTIN JOHN EVANS
Status Location Address State License Number
ACTIVE

14 FORT CAROLINE CT

BUNNELL, FL 32110

CFC057676 (Exp: 08/31/2026)
BENITO JEANTY
Status Location Address State License Number Phone Fax
CANCEL

37 RAINTREE PLACE

PALM COAST, FL 32164

EC13001454 (Exp: 08/31/2016) (386)586-1294 386-586-1346

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 06/29/2007 FINAL APPROVED PGALLMANN
Note: Per Paul
STORMWATER FINAL INSPECTION 06/26/2007 APPROVED - AS NOTED DRANDALL
Note: THIS IS A REINSPECTION Approved based on new survey, with additional elevations along left side. Per DR.//wk 89 sq ft road damage. $812.00.//wk per DR
STORMWATER FINAL INSPECTION 06/25/2007 Disapproved -FEE REQUIRED DRANDALL
Note: need surveyors shots entire left side of house to show flow direction.....89 sf road damage $812.00
UTILITY COMPANY FINAL 06/22/2007 APPROVED MBACON
PRE DRIVEWAY 05/03/2007 APPROVED DRANDALL
STORMWATER FINAL INSPECTION 04/30/2007 CANCELLED BY INSPECTOR LAPTEKAR
Note: this inspection cannot be scheduled//final surveys have not been received for review
DRIVEWAY 04/20/2007 Disapproved -FEE REQUIRED DRANDALL
Note: per field check//scheduled driveway..... must have a mim. of 5" of concrete above culvert pipe......sidewalk does not show on survey, summit new survey to show sidewalk for stormwater approval
STORMWATER FINAL INSPECTION 04/19/2007 CANCELLED BY INSPECTOR LAPTEKAR
Note: CALLED BY RICHARD this inspection cannot be scheduled//final surveys are required for review//driveway inspection before pour also required.
INSULATION INSPECTION 12/29/2006 APPROVED CMINI
Note: THIS IS A REINSPECTION
ALL ROUGH 12/19/2006 APPROVED - AS NOTED PGALLMANN
Note: NEED APPROVED ENERGY CALCULATIONS BY INSULATION.
ALL ROUGH 12/15/2006 Disapproved - NO FEE JGIBSON
Note: No inspections will be given until correct electrical contractor is listed KC electrical contractor has said he is not doing work or has done any work @ this address.
INSULATION INSPECTION 12/07/2006 Disapproved - NO FEE PGALLMANN
Note: INSTALLED PRE-MATURELY.
ALL ROUGH 12/07/2006 Disapproved -FEE REQUIRED PGALLMANN
Note: THIS IS A REINSPECTION... PREVIOUS ITEMS NOT CORRECTED. E.G., PLUMBING; ELECTRIC; ENERGY CALCULATIONS.
LATH /BRICK FLASHING 11/15/2006 APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
ALL ROUGH 11/13/2006 Disapproved -FEE REQUIRED JGIBSON
Note: Electrical not completed, energy calcs need revisions, no test on sanitary, fire blocking not solid in many areas,GFCI in 1/2 bath cannot service GFCI in laundry room, incomplete list.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 11/07/2006 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION. NEE LETTER FROM ENGINEER FOR SCABED TRUSSES IN GARAGE TO GAIN FULL BEARING. ALSO LETTER ON SCABED TRUSS WHERE MGT IS NAILED IN GARAGE.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/05/2006 Disapproved -FEE REQUIRED ACOOPER
Note: Pour all missed cells, need engineering on all truss modifications to H-18,19,20,11. All RO1 trusses need engineering to extend the bottom cord to fit on bearing wall, compkly with bearing wall detail for LVL-2 on both ends of LVL. In complete inspection, Not ready for inspection.
LINTEL 08/09/2006 APPROVED ARITTER
Note: THIS IS A REINSPECTION
LINTEL 08/07/2006 Disapproved -FEE REQUIRED ARITTER
Note: MISSING CELL BACK WALL MARKED ON PLAN.CLEAN BOTTOM CELLS.
FOUNDATION SURVEY APPROVED BY STORMWATER 08/04/2006 APPROVED WKINELL
LATH /BRICK FLASHING 07/28/2006 Disapproved -FEE REQUIRED PGALLMANN
Note: APPARENTLY CALLED IN LATH IN LIEU OF LINTEL. NOT READY FOR LATH/FAIL.
MONOLITHIC SLAB INSPECTION/SLAB 06/23/2006 APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB INSPECTION/SLAB 06/22/2006 Disapproved -FEE REQUIRED JLEVRAULT
Note: MISSING ONE DOWEL ROD - HILITED ON PLANS.
FIRST ROUGH PLUMBING INSPECTION 06/16/2006 APPROVED PGALLMANN

Review History

Department Status Date In Date Out
ZON COMPLETE 04/23/2007 04/26/2007
Note: Released By: JGONZALEZ
SW1 COMPLETE 04/23/2007 04/23/2007
Note: Released By: LAPTEKAR Builder wants to add 3' x 55' sidewalk to side of house facing Whittlesey. WIll forward to zoning for ARC review.
SW1 HOLD 01/26/2007 01/26/2007
Note: Held By: LAPTEKAR received a new survey with a revised benchmark...however a topo survey with a revised benchmark was required...the survey brought in 1/26/07 was only a FFE survey. In order to generate a swale plan the new benchmark needs to be referenced on a sealed topo survey that also has elevations of the edge of pavement and drainage structures.
BLD COMPLETE 12/14/2006 12/20/2006
Note: Released By: CCOTE Approved for Release. REVISION: Revised energy calcs.
SW1 HOLD 10/27/2006 10/27/2006
Note: Held By: EBLACKER A routine audit of surveys has revealed that the bench mark referenced in the topo survey for this property does not exist at the stated location. The poles must have been moved since the survey was done. There is a new house under construction right where the Bench Mark was located (#25). Now there is a pole at the left property line of house #23 instead of at the right side as shown on the survey, but it has no bench mark. There is also a pole at the right property line of house number 25 with a bench mark nail in it. However this nail does not coinside with the elevations given so it must be for the house under construction at #25. We need a new survey to complete the swale plan.
BLD COMPLETE 10/16/2006 10/17/2006
Note: Released By: CCOTE Approved for Release. REVISION: Truss Repairs R01, H13, H14, H19, H20, H10.
BLD COMPLETE 04/17/2006 04/19/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 04/06/2006 04/11/2006
Note: Held By: CCOTE The City received revised drawings however the following items from the previous comments were not addressed and must be submitted in order to complete the Building Permit Application plan review. All items must be submitted on a signed and sealed drawing (2 copies of each). 1. Provide beam size, type and grade for all beams to be used including but not limited to LVL-1, LVL-2, LVL-3 and BEAM.
BLD HOLD 03/27/2006 03/29/2006
Note: Held By: CCOTE The City received revised drawings however the following items from the previous comments were not addressed and must be submitted in order to complete the Building Permit Application plan review. All items must be submitted on a signed and sealed drawing (2 copies of each). 1. Provide beam size, type and grade for all beams to be used including but not limited to LVL-1, LVL-2, LVL-3 and BEAM. 2. Provide connectors to be used to secure beams all connection points including but not limited to exterior masonry walls, interior framed walls and posts. 3. Provide connectors to secure bearing posts to foundation and to beam. 4. Provide lintel information indicating size and reinforcing for all lintels including but not limited to windows, doors, garage doors, entry and covered porch. Ideally this would be added to window and door schedule with a column for this. Example: "8F16-1B/1T". In addition add all masonry openings. A lintel schedule was provided however there are 4 types and the floor plan has no reference to the lintel marks. Please indicate which lintel type to use at each masonry opening. 5. The drawings do not indicate truss uplift connectors to be used for each truss. A note stating to use a HETA20 unless otherwise noted but the 2nd floor is wood framed and there is no connector specified for this condition. 6. Provide more specific information for exterior guard rail as to how it will be constructed to meet the requirements of section R312. Provide post information, spacing and how posts are connected at the base. 7. Provide detail as to how roof around perimeter of balcony floor is to be framed and connected.
BLD HOLD 03/03/2006 03/03/2006
Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. All items must be submitted on a signed and sealed drawing (2 copies of each). 1. Provide framing size, grade, spacing for 2nd floor balcony. 2. Indicate connectors to be used to secure 2nd floor framing to wall, beam and lintel. 3. Provide beam size, type and grade for all beams to be used including but not limited to LVL-1, LVL-2, LVL-3 and BEAM. 4. Provide connectors to be used to secure beams all connection points including but not limited to exterior masonry walls, interior framed walls and posts. 5. LVL-1 is bearing on a wood framed wall at the stairwell. This wall is not indicated as a bearing wall and no post is indicated. The foundation plan does not show a thickened slab here nor a column footing. How is this beam supported at this end and how is connected and how is a continuous load path to the foundation achieved? 6. Provide a 2-story wall section indicating all framing components as well as connectors used to secure 2nd floor walls to beams and walls below. 7. Provide connectors to secure bearing posts to foundation and to beam. 8. Provide lintel information indicating size and reinforcing for all lintels including but not limited to windows, doors, garage doors, entry and covered porch. Ideally this would be added to window and door schedule with a column for this. Example: "8F16-1B/1T". In addition add all masonry openings. 9. The drawings do not indicate truss uplift connectors to be used for each truss. A note stating to use a HETA20 unless otherwise noted but the 2nd floor is wood framed and special connectors for girders and etc. are not noted on the plan. Please submit a project specific truss connector schedule listing connector(s) to be used for each connection point for each truss as well connectors to be used for other items including but not limited to beams, columns and hand framed members. 10. The truss connector specified for truss 21 is noted as a HGT-2. Based on the Simpson catalog this will require the following: a. Masonry ends: Requires anchorage of two 3/4" diameter anchors with an embedment of 12". Please clarify how this will be accomplished. 11. Provide more specific information for exterior guard rail as to how it will be constructed to meet the requirements of section R312. Provide post information, spacing and how posts are connected at the base. 12. Provide detail as to how roof around perimeter of balcony floor is to be framed and connected.
ZON COMPLETE 03/02/2006 03/03/2006
Note: Released By: HHERKERT
SW1 HOLD 11/23/2005 12/12/2005
Note: Held By: LAPTEKAR Need 2 sealed topo syurveys using 1988NAVD data with a benchm,ark that is not a cap in the road. Also need a grading plan showing proposed elevations. Need measurement of driveway flairs to the intersection on the site plan.
ZON HOLD 11/23/2005 02/15/2006
Note: Held By: HHERKERT additional landscape is required on the left side of the structure facing Whittleset Lane
SW1 COMPLETE 03/02/2006
Note: Released By: LAPTEKAR recieved topo surveys...3/2

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤812.00 06/29/2007
REINSPECTION FEE ¤40.00 06/29/2007
REINSPECTION FEE ¤40.00 06/29/2007
REINSPECTION FEE ¤40.00 06/29/2007
REINSPECTION FEE ¤40.00 06/29/2007
REINSPECTION FEE ¤40.00 06/29/2007
REINSPECTION FEE ¤40.00 06/29/2007
REVISION ¤40.00 06/29/2007
REVISION ¤40.00 06/29/2007
STORMWATER REINSPECTION FEE ¤35.00 06/29/2007
STORMWATER REINSPECTION FEE ¤35.00 06/29/2007
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 04/21/2006
ADMIN FEE ¤20.00 04/21/2006
ARC HOUSE REVIEW ¤125.00 04/21/2006
BUILDING CODE ADMIN FUND ¤22.83 04/21/2006
ELECTRIC FEE ¤225.00 04/21/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 04/21/2006
STORM WATER PERMIT FEES ¤80.00 04/21/2006
FIRE RES IMPACT FEE 4-1-05 ¤173.47 04/21/2006
MECHANICAL FEE ¤225.00 04/21/2006
PERMIT FEE ¤1,267.50 04/21/2006
PARKS IMPACT FEE 11-2-04 ¤1,120.91 04/21/2006
PLAN CHECK FEE ¤130.00 04/21/2006
PLUMBING FEE ¤225.00 04/21/2006
RADON FEE ¤22.83 04/21/2006
Fees Total Due: ¤0.00 Total Paid: ¤11,688.05