I want to search for...
Permit #2005110586
Permit Details
Status: COED
| COMMERCIAL SQUARE FOOTAGE: 7780 sqft |
| Total Square Footage: 7780 sqft |
| Subdivision: 2085 - Tidelands at the Village Phase II |
| Job Phone: (407)838-1486 |
| Location Address: 2 RIVERVIEW BEND N |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 02/07/2006 |
| NOC: RECORDED |
| Applicant name: JAMES NICHOLSON BOYCE IV |
| Owner: CENTEX DESTINATION PROPERTIES |
| Contracted Stated Job Value: ¤1,500,000.00 |
| Job Description: CLUBHOUSE |
| Type: CN |
Contractor
CENTEX DESTINATION PROPERTIES
| Status | Location Address | Mailing Address | State License Number | Phone |
| CANCEL |
1064 GREENWOOD BLVD LAKE MARY, FL 32746 |
STE. 200 LAKE MARY, FL 32746 |
CGC1508651 (Exp: 08/31/2010) | (407)838-1486 |
Sub Contractors
TRUMAN E GAILEY JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
231 Jean St. DAYTONA BEACH, FL 32114 |
EC0000265 (Exp: 08/31/2026) | (386) 255-1418 | (386)255-3429 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
GARY WAYNE EVERS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 740106 ORANGE CITY, FL 32763 |
CFC050566 (Exp: 08/31/2026) | 386-775-0909 | 386-775-0918 |
WAYNE STEED
| Status | Location Address | State License Number | Phone |
| CANCEL |
318 N. PINE AVENUE IVERNESS, FL 34450 |
CCC058299 (Exp: 08/31/2010) | (352)637-2422 |
RICHARD PHILLIP HOUGHTON
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
12815 AUTOMOBILE BLVD. CLEARWATER, FL 33762 |
CAC050371 (Exp: 09/30/2008) | (727)573-5733 | (727)573-2573 |
RONALD D PIERSON
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1510 DILLARD RD ASTOR, FL 32102 |
16425 (Exp: 08/31/2008) | (000)000-0000 | (386)749-0293 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 05/10/2007 | FINAL APPROVED | JLEVRAULT |
| ENGINEERING FINAL | 04/18/2007 | APPROVED | DMAY |
| UTILITY COMMERCIAL FINAL | 04/18/2007 | APPROVED | KKING |
| Note: THIS IS A REINSPECTION | |||
| LANDSCAPE FINAL | 04/12/2007 | APPROVED | WBUTLER |
| FIRE FINAL | 04/12/2007 | APPROVED | JPATTEE |
| UTILITY COMMERCIAL FINAL | 04/12/2007 | Disapproved - NO FEE | KKING |
| Note: The grade work around the grease interseptor is to low. Raise the grade then raise the grease interseptor to match. The interseptor can not be in a depression. | |||
| PLUMBING FINAL | 04/10/2007 | APPROVED | PGALLMANN |
| Note: | |||
| GAS FINAL | 03/29/2007 | APPROVED | JMCGOWEN |
| Note: | |||
| GAS ROUGH | 03/16/2007 | APPROVED | JMCGOWEN |
| ELECTRICAL FINAL | 03/16/2007 | APPROVED | RMARVEL |
| H.V.A.C. FINAL | 03/16/2007 | APPROVED | JMCGOWEN |
| ALL ROUGH | 03/14/2007 | APPROVED - AS NOTED | JLEVRAULT |
| Note: NEED TO INSPECT COMPLETE GAS LINE AND TRACER. | |||
| GAS ROUGH | 03/06/2007 | APPROVED | JLEVRAULT |
| Note: | |||
| GAS ROUGH | 03/05/2007 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: NO PRESSURE ON GAUGE. INSTALL CLAMPS ON GAS RISER. | |||
| ALL ROUGH | 02/21/2007 | APPROVED | JLEVRAULT |
| Note: CEILING CLOSE-IN. | |||
| COMMERCIAL POWER INSPECTION | 02/06/2007 | APPROVED | RMARVEL |
| H.V.A.C. ROUGH | 01/24/2007 | APPROVED - AS NOTED | JMCGOWEN |
| Note: This inspection is for the walk-in refrigeration units-as per Mark NEED 4" SEPERATION OF DUCSTS WEST MECHANICAL ROOM WORKING CLEARANCE. NEED TO TERMINATE RETURN IN ACTIVITIES ROOM. WILL CHECK AT ABOVE CEILING INSPECTION | |||
| SECOND ROUGH PLUMBING INSPECTION | 12/29/2006 | APPROVED - AS NOTED | JGIBSON |
| Note: grease interceptor | |||
| INSULATION INSPECTION | 11/22/2006 | APPROVED | JLEVRAULT |
| ALL ROUGH | 11/20/2006 | APPROVED - AS NOTED | JLEVRAULT |
| Note: CHECK ALL LEDGER BOLTS AT INSULATION INSPECTION. | |||
| THRESHOLD/AFFIDAVIT | 10/31/2006 | APPROVED | PPROVIDER |
| Note: Law & Associates, Inc. Threshold inspectors report dated 10/31/06 | |||
| FOOTER | 10/06/2006 | APPROVED | PPROVIDER |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/28/2006 | APPROVED - AS NOTED | CMINI |
| Note: FINISH ANCHOR BOLTS ON TRUSS LEDGER BOARDS 2' O.C. PER PLAN,FINISH SHEATHING PIECES. CHECK ON ALL ROUGH. | |||
| LINTEL | 08/21/2006 | APPROVED | PPROVIDER |
| Note: Threshold inspectors report | |||
| POURED CELL | 06/19/2006 | APPROVED | PPROVIDER |
| Note: Threshold inspectors report | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 06/09/2006 | APPROVED | PPROVIDER |
| Note: Threshold inspectors report. | |||
| FIRST ROUGH PLUMBING INSPECTION | 06/06/2006 | APPROVED | JMCGOWEN |
| STEM FOOTING FOUNDATION | 05/08/2006 | APPROVED | PPROVIDER |
| Note: Threshold inspectors report. | |||
| FOOTER | 04/27/2006 | APPROVED | PPROVIDER |
| Note: Threshold inspectors report | |||
| TEMPORARY POLE | 04/07/2006 | APPROVED | JMCGOWEN |
| Note: called on 4-12-06 Susan at FPL for a temp pole. Some confusion with the dates of inspection being approved. | |||
| FIRST ROUGH PLUMBING INSPECTION | 03/14/2006 | APPROVED | TOUTLAND |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/23/2006 | 01/24/2006 |
| Note: Released By: LWOODROME | |||
| BLD | HOLD | 12/07/2005 | 12/07/2005 |
| Note: Held By: FREODICA CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application Number 2005110586-Tidelands Clubhouse 1. Provide copies of product approval data and installation instructions for exterior windows and doors, at the job site at the time inspection. 2. Provide copies of the roofing manufacturer specifications & installation instructions at the job site. 3. Provide energy calculations. 4. Provide details of barrel vaulted tile roof over exercise room to meet FBC 2004/B section 1507.3.2 5. Provide draftstop location in attic spaces per note 3, sheet A3.1. 6. Clarify roof sheeting thickness. (Drawing A3.1 references ½" while A6.1 & S-4 references 5/8". 7. Provide subcontractor name, phone No. &license No. on building permit application for LP gas installation or indicate on drawing if LP gas system installation will be installed in a separate building permit application. 8. Provide size of LP gas underground tank. 9. Provide separate permit application for kitchen hood and equipments for plan review. 7. On M1, clarify plan key notes 5 & 11 for outside air duct as there are (2) number 5. 8. On M2, clarify split system schedule as there are (2) AHU-2/CU-2. 9. On E-3, clarify if location of condensing units for freezer, cooler & ice maker is allowed by Galvin Design group Inc. as reference note indicate that those equipments shall be located on roof (FS-2). | |||
| FD1 | COMPLETE | 11/29/2005 | 11/29/2005 |
| Note: Released By: JPATTEE Very good set of food service plans, however, there is a seperate submittal for permitting for hood installtion and for extinguishing system installation. ( these submittals are not approved at this time) |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 05/10/2007 |
| REVISION | ¤40.00 | 05/10/2007 |
| ADMIN FEE | ¤20.00 | 02/07/2006 |
| BUILDING CODE ADMIN FUND | ¤38.90 | 02/07/2006 |
| ELECTRIC FEE | ¤930.00 | 02/07/2006 |
| FIRE COMM IMPACT FEE 4-1-05 | ¤3,740.62 | 02/07/2006 |
| FIRE PLANS REVIEW | ¤77.80 | 02/07/2006 |
| MECHANICAL FEE | ¤930.00 | 02/07/2006 |
| PERMIT FEE | ¤8,250.00 | 02/07/2006 |
| PLAN CHECK FEE | ¤1,725.00 | 02/07/2006 |
| PLUMBING FEE | ¤930.00 | 02/07/2006 |
| RADON FEE | ¤38.90 | 02/07/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤16,761.22 |