I want to search for...

Permit #2005110603

Permit Details

Status: COED

Parcel Id: 07-11-31-7011-00070-0210
CONDITIONED SPACE: 3301 sqft
GARAGE: 574 sqft
OPENED PORCH (WITH ROOF) : 104 sqft
OPENED PORCH (WITH ROOF) : 96 sqft
Total Square Footage: 4075 sqft
Block: 0007
Subdivision: -
Job Phone: (904)363-7626
Location Address: 76 BEACHWAY DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/30/2005
NOC: RECORDED
Owner: WEEKLEY HOMES LP

Address

1111 N. POST OAK ROAD

HOUSTON, TX 77055

Lot: 210
Contracted Stated Job Value: ¤18,000.00
Job Description: SINGLE RESIDENSE
Type: CN

Contractor

WEEKLEY HOMES,L.P.
Status Location Address State License Number Phone Fax
CANCEL

448 VICTORIA HILLS DRIVE

DELAND, FL 32724

CBC053082 (Exp: 08/31/2012) (386)775-7206 (386)775-1709

Sub Contractors

TYRENE SCOTT
Status Location Address State License Number
CANCEL

9556 HISTORIC KINGS RD ST #306

JACKSONVILLE, FL 32206

CAC035526 (Exp: 09/30/2008)
GARY WAYNE EVERS
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 740106

ORANGE CITY, FL 32763

CFC050566 (Exp: 08/31/2026) 386-775-0909 386-775-0918
JEFFREY LUIS CARRASCO
Status Location Address State License Number Phone Fax
CANCEL

665 W. COUNTY ROAD 2006

BUNNELL, FL 32110

CCC1325557 (Exp: 08/31/2010) 904-674-4730 904-268-0471
CHRISTIAN MASARIK
Status Location Address State License Number Phone Fax
CANCEL

6321 GOMEZ ROAD

ST. AUGUSTINE, FL 32084

EC13001175 (Exp: 08/31/2010) (904)829-2700 (904)829-2751

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 06/01/2006 FINAL APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 05/30/2006 Disapproved -FEE REQUIRED ARITTER
Note: THIS IS A REINSPECTION item one on noticed dated 5-24-06 incomplete "overcurrent protection"
FINAL COMPLETE BUILDING INSPECTION 05/24/2006 Disapproved -FEE REQUIRED JLEVRAULT
Note: MAXIMUM OVERCURRENT PROTECTION FOR CONDENSING UNIT IS 50 AMPS - A 60 AMP BREAKER IS INSTALLED, INSTALL CLAMPS WITHIN 12' OF CONDENSING UNIT DISCONNECTS. NO WATER HAMMER ARRESTOR FOR DISHWASHER.
RESIDENTIAL EARLY POWER 05/18/2006 APPROVED RMARVEL
UTILITY COMPANY FINAL 05/16/2006 APPROVED RANDRADE
STORMWATER FINAL INSPECTION 05/15/2006 APPROVED BFCHAMBERLAIN
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 05/09/2006 Disapproved -FEE REQUIRED BFCHAMBERLAIN
Note: Seed and straw along right and rear prop lines; stabilize exposed earth on bank at right front prop line.
PRE DRIVEWAY 03/23/2006 APPROVED BFCHAMBERLAIN
Note: THIS IS A REINSPECTION
PRE DRIVEWAY 03/20/2006 Disapproved -FEE REQUIRED BFCHAMBERLAIN
Note: NO REBAR/
LATH /BRICK FLASHING 03/08/2006 APPROVED PGALLMANN
INSULATION INSPECTION 02/24/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
INSULATION INSPECTION 02/23/2006 Disapproved -FEE REQUIRED MMOORE
Note: THIS IS A REINSPECTION 1. NOT COMPLETED 2ND FLOOR
INSULATION INSPECTION 02/22/2006 CANCELLED BY APPLICANT MMOORE
ALL ROUGH 02/20/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
ALL ROUGH 02/17/2006 CANCELLED BY APPLICANT MMOORE
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 02/10/2006 APPROVED JLEVRAULT
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 02/09/2006 Disapproved -FEE REQUIRED JLEVRAULT
Note: THIS IS A REINSPECTION RODS STILL COMING LOOSE.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 02/08/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. THREADED DOWN-ROD HOLES NOT CLEANED OUT ACCORDING TO SUPERINTENDENT AS REQUIRED IN THE DIRECTIONS ON THE TUBES OF EPOXY USED FOR ANCHORING THE BOTTOMS OF ALL-THREADS./ RODS PULLING OUT OF HOLES. 2. GROUT TRUSSES NOT FULL BEARING 3. SUPERINTENDENT TOLD ME HE DID NOT CLEAN-OUT HOLES AND EPOXY TUBES SPECIFY CLEANING-OUT OF HOLES/ DOWN-RODS NOT EPOXEED INTO "CLEANED-OUT" HOLES. 4. THERE IS FAILURE OF RODS AT VARIOUS AREAS.
LINTEL 01/19/2006 APPROVED MMOORE
FOUNDATION SURVEY APPROVED BY STORMWATER 01/18/2006 APPROVED MBRENNAN
MONOLITHIC SLAB INSPECTION/SLAB 01/11/2006 APPROVED MMOORE
MONOLITHIC SLAB INSPECTION/SLAB 01/10/2006 CANCELLED BY APPLICANT ARAYMOND
FIRST ROUGH PLUMBING INSPECTION 01/09/2006 APPROVED MMOORE

Review History

Department Status Date In Date Out
BLD COMPLETE 12/19/2005 12/21/2005
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 12/02/2005 12/05/2005
Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. The beam sheets submitted must be signed and sealed by an architect or engineer or 2. The beam sizes must be included on a signed and sealed drawing or 8-1/2 x 11 sheet.
ZON COMPLETE 12/02/2005 12/02/2005
Note: Released By: HHERKERT
SW1 HOLD 11/28/2005 12/12/2005
Note: Held By: LAPTEKAR Need two sealed topographic surveys using 1988NAVD with a benchmark that is not a cap in the road and a lot grading plan that has proposed elevations next to the existing elevations on the topo.
ZON HOLD 11/28/2005 11/30/2005
Note: Held By: HHERKERT hold for ARC meeting 12-2-05
SW1 COMPLETE 12/30/2005
Note: Released By: LAPTEKAR

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 06/05/2006
REINSPECTION FEE ¤40.00 06/05/2006
REINSPECTION FEE ¤40.00 06/05/2006
REINSPECTION FEE ¤40.00 06/05/2006
REINSPECTION FEE ¤40.00 06/05/2006
REINSPECTION FEE ¤40.00 06/05/2006
STORMWATER REINSPECTION FEE ¤35.00 06/05/2006
STORMWATER REINSPECTION FEE ¤35.00 06/05/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 12/30/2005
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 12/30/2005
STORM WATER PERMIT FEES ¤80.00 12/30/2005
ADMIN FEE ¤20.00 12/30/2005
ARC HOUSE REVIEW ¤125.00 12/30/2005
BUILDING CODE ADMIN FUND ¤20.38 12/30/2005
ELECTRIC FEE ¤216.60 12/30/2005
FIRE RES IMPACT FEE 4-1-05 ¤173.47 12/30/2005
MECHANICAL FEE ¤216.60 12/30/2005
PERMIT FEE ¤1,212.90 12/30/2005
PARKS IMPACT FEE 11-2-04 ¤1,120.91 12/30/2005
PLAN CHECK FEE ¤124.40 12/30/2005
PLUMBING FEE ¤216.60 12/30/2005
RADON FEE ¤20.38 12/30/2005
Fees Total Due: ¤0.00 Total Paid: ¤10,705.75