I want to search for...
Permit #2005110604
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-01490-0120 |
| CONDITIONED SPACE: 3292 sqft |
| GARAGE: 574 sqft |
| OPENED PORCH (WITH ROOF) : 104 sqft |
| OPENED PORCH (WITH ROOF) : 159 sqft |
| Total Square Footage: 4129 sqft |
| Block: 0149 |
| Subdivision: - |
| Job Phone: (904)363-7626 |
| Location Address: 23 EDITH POPE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/30/2005 |
| NOC: RECORDED |
| Owner: WEEKLY HOMES L.P. |
|
Address 1111N. POST OAK ROAD HOUSTON, TX 77055 |
| Lot: 120 |
| Contracted Stated Job Value: ¤18,000.00 |
| Job Description: SINGLE RESIDENSE |
| Type: CN |
Contractor
WEEKLEY HOMES,L.P.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
448 VICTORIA HILLS DRIVE DELAND, FL 32724 |
CBC053082 (Exp: 08/31/2012) | (386)775-7206 | (386)775-1709 |
Sub Contractors
TYRENE SCOTT
| Status | Location Address | State License Number |
| CANCEL |
9556 HISTORIC KINGS RD ST #306 JACKSONVILLE, FL 32206 |
CAC035526 (Exp: 09/30/2008) |
GARY WAYNE EVERS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 740106 ORANGE CITY, FL 32763 |
CFC050566 (Exp: 08/31/2026) | 386-775-0909 | 386-775-0918 |
JEFFREY LUIS CARRASCO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
665 W. COUNTY ROAD 2006 BUNNELL, FL 32110 |
CCC1325557 (Exp: 08/31/2010) | 904-674-4730 | 904-268-0471 |
CHRISTIAN MASARIK
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
6321 GOMEZ ROAD ST. AUGUSTINE, FL 32084 |
EC13001175 (Exp: 08/31/2010) | (904)829-2700 | (904)829-2751 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 08/29/2006 | FINAL APPROVED | KSAMPICO |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 08/28/2006 | Disapproved -FEE REQUIRED | KSAMPICO |
| Note: House locked. | |||
| FINAL COMPLETE BUILDING INSPECTION | 08/25/2006 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Illumination violation not addressed | |||
| FINAL COMPLETE BUILDING INSPECTION | 08/24/2006 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Rear egress doors must be illuminated....install porch light | |||
| FINAL COMPLETE BUILDING INSPECTION | 08/07/2006 | Disapproved -FEE REQUIRED | KSAMPICO |
| Note: Missing 2nd receptacle at kitchen kneewall. 1st recep. not finished. Outside panel not labeled. Missing light at rear of home. | |||
| FINAL COMPLETE BUILDING INSPECTION | 08/03/2006 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: THIS IS A REINSPECTION upstairs gfci recepticle does not trip, need arc sheild at masterbath mirror recepticle. | |||
| FINAL COMPLETE BUILDING INSPECTION | 08/02/2006 | CANCELLED BY APPLICANT | JHINDMAN |
| STORMWATER FINAL INSPECTION | 07/21/2006 | APPROVED | GLALIMA |
| STORMWATER FINAL INSPECTION | 07/21/2006 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: PIN ALL SOD ON BACK BANK , THEN TAKE AWAY OVER LAPING GRASS RIGHT SIDE AND MAKE A MORE DEFINED SWALE RIGHT. | |||
| UTILITY COMPANY FINAL | 07/20/2006 | APPROVED | MBACON |
| RESIDENTIAL EARLY POWER | 07/10/2006 | APPROVED | KSAMPICO |
| DRIVEWAY | 06/30/2006 | APPROVED | LAPTEKAR |
| Note: THIS IS A REINSPECTION | |||
| DRIVEWAY | 06/28/2006 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: SILT FENCE MUST BE INSTILLED 4 '' IN GROUND , IN BACK YARD AT WATERWAY . AND AT CULVERT INLET IN FRONT OF HOUSE . COVER 50% OF PIPE | |||
| INSULATION INSPECTION | 05/30/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 05/23/2006 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: As per last inspectors request. See waste stack in kitchen pantry....It is open into attic.Must firestop this area. | |||
| INSULATION INSPECTION | 05/22/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Missing fire stop @ waste stack still no test on sanitary. | |||
| INSULATION INSPECTION | 05/17/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: NEED TO DRAFTSTOP WHERE THE STRAPS COME DOWN ON THE FRONT WALL ON LEFT OF HOUSE. ALSO THE HOLE IN SECOND FLOOR NEXT TO TOILET DRAIN.NO ENERGY CALCS IN BOX. | |||
| ALL ROUGH | 05/12/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 05/09/2006 | APPROVED | JGIBSON |
| ALL ROUGH | 05/09/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Trusses in garage not nailed in buckets, no test on sanitary, draft stop @ dead space in bonus room, box out around HVAC in garage | |||
| LATH /BRICK FLASHING | 05/05/2006 | APPROVED | CMINI |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/01/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/10/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Not ready need letter on LVL where 3'' soil stacck was drilled. | |||
| LINTEL | 02/22/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 02/21/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Missed dowel in rear of house not drilled to proper depth & epoxy not mixed correctly. | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 02/16/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 02/09/2006 | APPROVED | JGIBSON |
| FIRST ROUGH PLUMBING INSPECTION | 02/07/2006 | APPROVED | PGALLMANN |
Review History
| Department | Status | Date In | Date Out |
| BLD | CANCEL | 04/19/2006 | 04/20/2006 |
| Note: Revision: Truss and beam repair | |||
| BLD | COMPLETE | 12/19/2005 | 12/21/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | HOLD | 12/09/2005 | 12/13/2005 |
| Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. The beam sheets submitted must be signed and sealed by an architect or engineer or 2. The beam sizes must be included on a signed and sealed drawing or 8-1/2 x 11 sheet. | |||
| ZON | COMPLETE | 12/09/2005 | 12/09/2005 |
| Note: Released By: HHERKERT LDC effective 12-6-05, no lot coverage, max impervious allowed 70% | |||
| SW1 | HOLD | 11/28/2005 | 12/13/2005 |
| Note: Held By: LAPTEKAR Need 2 sealed toppgraphic surveys using 1988 NAVD with a benchmark that is not a cap in the road Lot grading plan needs to show proposed elevations in the swale and porposed elevations next to existing elevations from the topo. | |||
| ZON | HOLD | 11/28/2005 | 11/30/2005 |
| Note: Held By: HHERKERT total lot coverage allowed is 35% actual lot coverage is 36% | |||
| SW1 | COMPLETE | 12/30/2005 | |
| Note: Released By: LAPTEKAR |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 09/20/2006 |
| REINSPECTION FEE | ¤40.00 | 09/20/2006 |
| REINSPECTION FEE | ¤40.00 | 09/20/2006 |
| REINSPECTION FEE | ¤40.00 | 09/20/2006 |
| REINSPECTION FEE | ¤40.00 | 09/20/2006 |
| REINSPECTION FEE | ¤40.00 | 09/20/2006 |
| REINSPECTION FEE | ¤40.00 | 09/20/2006 |
| REINSPECTION FEE | ¤40.00 | 09/20/2006 |
| REINSPECTION FEE | ¤40.00 | 09/20/2006 |
| REINSPECTION FEE | ¤40.00 | 09/20/2006 |
| REINSPECTION FEE | ¤40.00 | 09/20/2006 |
| REINSPECTION FEE | ¤40.00 | 09/20/2006 |
| REVISION | ¤40.00 | 09/20/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 09/20/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 09/20/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 12/30/2005 |
| ADMIN FEE | ¤20.00 | 12/30/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 12/30/2005 |
| BUILDING CODE ADMIN FUND | ¤20.65 | 12/30/2005 |
| ELECTRIC FEE | ¤217.20 | 12/30/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 12/30/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/30/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 12/30/2005 |
| MECHANICAL FEE | ¤217.20 | 12/30/2005 |
| PERMIT FEE | ¤1,216.80 | 12/30/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 12/30/2005 |
| PLAN CHECK FEE | ¤124.80 | 12/30/2005 |
| PLUMBING FEE | ¤217.20 | 12/30/2005 |
| RADON FEE | ¤20.65 | 12/30/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,992.39 |