I want to search for...

Permit #2005110625

Permit Details

Status: COED

Parcel Id: 07-11-31-7031-00400-0070
CONDITIONED SPACE: 1957 sqft
GARAGE: 432 sqft
OPENED PORCH (WITH ROOF) : 138 sqft
OPENED PORCH (WITH ROOF) : 36 sqft
Total Square Footage: 2563 sqft
Block: 0040
Subdivision: -
Job Phone: (386) 445-4515
Location Address: 27 RICHMOND DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/20/2005
NOC: RECORDED
Applicant name: GREGORY LEE LE PERA
Owner: FRIZELL, JAMES P. & MARIE M. H&W

Address

342 CORONA AVENUE

COCOA BEACH, FL 32931

Lot: 070
Contracted Stated Job Value: ¤78,280.00
Job Description: SINGEL FAMILY RESIDENCE
Type: CN

Contractor

WAYNE HOMES BY CENTEX
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

385 DOUGLAS AVE

ALTAMONTE SPRINGS, FL 32714

STE 3000

ALTAMONTE SPRINGS, FL 32714

CBC055301 (Exp: 09/30/2008) (386) 445-4515 (386)446-6285

Sub Contractors

MICHAEL G MORELLO JR
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32137

CAC014293 (Exp: 08/31/2014) (386)447-3950 (386)446-4614
GREGORY A HAGEMAN
Status Location Address State License Number Phone
ACTIVE

545 Parque Drive

Ormond Beach, FL 32174

CCC021394 (Exp: 08/31/2026) (386) 672-2821
JOHN FREDERICK WANERKA
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 350214

BUNNELL, FL 32135

EC0000585 (Exp: 08/31/2022) 386-446-9626 386-445-3131

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 05/24/2006 FINAL APPROVED JHINDMAN
STORMWATER FINAL INSPECTION 05/22/2006 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION 22 s.f. road damage $276
UTILITY COMPANY FINAL 05/19/2006 APPROVED RANDRADE
Note: INSPECTOR WAS RICK DRIGGERS
STORMWATER FINAL INSPECTION 05/18/2006 CANCELLED BY APPLICANT GLALIMA
Note: Cancel per Dave......sod not replaced
STORMWATER FINAL INSPECTION 05/16/2006 Disapproved - NO FEE GLALIMA
Note: SOD FROM CENTER BACK ' TO RIGHT PROPERTY LINE , BECAUSE POF WATER WAY, REPAIR ROAD DAMAGE 20 ft
RESIDENTIAL EARLY POWER 05/02/2006 APPROVED PGALLMANN
DRIVEWAY 04/17/2006 APPROVED GLALIMA
INSULATION INSPECTION 03/14/2006 APPROVED JGIBSON
ALL ROUGH 03/10/2006 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
ALL ROUGH 03/07/2006 Disapproved -FEE REQUIRED DROCKWELL
Note: fix electric boxes that have too much fill
LATH /BRICK FLASHING 03/07/2006 APPROVED DROCKWELL
FRAMING 03/03/2006 APPROVED TOUTLAND
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 02/21/2006 APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 02/08/2006 Disapproved -FEE REQUIRED PGALLMANN
Note: 1) Tear felt off of porch headers for inspection. 2) Grout under trusses where needed throughout. 3) Install vapor barrier under trusses where needed throughout. 4) Truss to truss straps over master bath are not connected. 5) 2-ply truss over master bath has pulled apart.
FOUNDATION SURVEY APPROVED BY STORMWATER 02/06/2006 APPROVED - AS NOTED LAPTEKAR
Note: survey submitted and approved
LINTEL 01/27/2006 APPROVED PGALLMANN
MONOLITHIC SLAB INSPECTION/SLAB 01/17/2006 APPROVED JHINDMAN
FIRST ROUGH PLUMBING INSPECTION 01/11/2006 APPROVED JHINDMAN
TEMPORARY POLE 01/11/2006 APPROVED JHINDMAN

Review History

Department Status Date In Date Out
BLD COMPLETE 02/09/2006 02/14/2006
Note: Released By: LWOODROME
BLD COMPLETE 12/09/2005 12/12/2005
Note: Released By: LWOODROME approved for release as noted on plan cover sheet. Review by FR
BLD HOLD 11/30/2005 12/02/2005
Note: Held By: FREODICA 1. Submit (1) copy of sheet 7 (exterior elevations) which is missing in the submitted package. 2. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 3. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 4. Indicate how attic access will be constructed to comply with FRC Section R309.2. 5. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0. CITY OF PALM COAST o 2 COMMERCE BLVD o PALM COAST, FL 32164 PHONE: 386-986-3780 o FAX: 386-986-3781 *The City is also requesting that there is a 6" x 6" area on the cover page (first drawing sheet) for City comments and approval stamp.
SW1 HOLD 11/29/2005 12/13/2005
Note: Held By: LAPTEKAR Need 2 sealed topographic surveys using 1988 NAVD data and a lot grading plan showing proposed elevations next to the existing topo elevations.
ZON COMPLETE 11/29/2005 11/30/2005
Note: Released By: HHERKERT
SW1 COMPLETE 12/16/2005
Note: Released By: LAPTEKAR

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤276.00 05/25/2006
EARLY POWER INSPECTION ¤40.00 05/25/2006
REINSPECTION FEE ¤40.00 05/25/2006
REINSPECTION FEE ¤40.00 05/25/2006
REVISION ¤40.00 05/25/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 12/20/2005
STORM WATER PERMIT FEES ¤80.00 12/20/2005
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 12/20/2005
ADMIN FEE ¤20.00 12/20/2005
ARC HOUSE REVIEW ¤125.00 12/20/2005
BUILDING CODE ADMIN FUND ¤12.82 12/20/2005
ELECTRIC FEE ¤144.00 12/20/2005
FIRE RES IMPACT FEE 4-1-05 ¤173.47 12/20/2005
MECHANICAL FEE ¤144.00 12/20/2005
PERMIT FEE ¤741.00 12/20/2005
PARKS IMPACT FEE 11-2-04 ¤1,120.91 12/20/2005
PLAN CHECK FEE ¤76.00 12/20/2005
PLUMBING FEE ¤144.00 12/20/2005
RADON FEE ¤12.82 12/20/2005
Fees Total Due: ¤0.00 Total Paid: ¤10,078.53