Permit #2005120084

Permit Details

Status: COED

Parcel Id: 07-11-31-7014-00020-0740
CONDITIONED SPACE: 2440 sqft
GARAGE: 681 sqft
OPENED PORCH (WITH ROOF) : 242 sqft
OPENED PORCH (WITH ROOF) : 71 sqft
Total Square Footage: 3434 sqft
Block: 0002
Subdivision: -
Job Phone: (386) 445-4515
Location Address: 27 COTTAGEGATE CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/28/2005
NOC: RECORDED
Applicant name: GREGORY LEE LE PERA
Owner: DOBELBOWER ELIZABETH J & DALLAS C. H&W
Lot: 740
Contracted Stated Job Value: ¤117,120.00
Job Description: SINGLE FAMILY
Type: CN

Contractor

WAYNE HOMES BY CENTEX
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

385 DOUGLAS AVE

ALTAMONTE SPRINGS, FL 32714

STE 3000

ALTAMONTE SPRINGS, FL 32714

CBC055301 (Exp: 09/30/2008) (386) 445-4515 (386)446-6285

Sub Contractors

STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
MICHAEL G MORELLO JR
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32137

CAC014293 (Exp: 08/31/2014) (386)447-3950 (386)446-4614
GARY WAYNE EVERS
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 740106

ORANGE CITY, FL 32763

CFC050566 (Exp: 08/31/2026) 386-775-0909 386-775-0918
GREGORY A HAGEMAN
Status Location Address State License Number Phone
ACTIVE

545 Parque Drive

Ormond Beach, FL 32174

CCC021394 (Exp: 08/31/2026) (386) 672-2821

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 06/23/2006 FINAL APPROVED JGIBSON
UTILITY COMPANY FINAL 06/22/2006 APPROVED TSCHWEERS
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 06/15/2006 APPROVED - AS NOTED BFCHAMBERLAIN
Note: 24 s.f. road damage............$292
UTILITY COMPANY FINAL 06/06/2006 Disapproved - NO FEE TSCHWEERS
Note: FAILED GRAVITY FAIL CLEAN OUT GLUED ON CAN'T OPEN TO CHECK PIPES
RESIDENTIAL EARLY POWER 06/06/2006 APPROVED RMARVEL
RESIDENTIAL EARLY POWER 06/05/2006 Disapproved -FEE REQUIRED RMARVEL
Note: all loose wires are to be boxed and secured.
DRIVEWAY 05/26/2006 APPROVED BFCHAMBERLAIN
TEMPORARY POLE 04/28/2006 APPROVED JMCGOWEN
Note: called susan at 4:00
LATH /BRICK FLASHING 04/28/2006 APPROVED JMCGOWEN
INSULATION INSPECTION 04/27/2006 APPROVED JGIBSON
GAS ROUGH 04/25/2006 APPROVED JMCGOWEN
ALL ROUGH 04/25/2006 APPROVED JMCGOWEN
Note: THIS IS A REINSPECTION
GAS ROUGH 04/21/2006 CANCELLED BY APPLICANT AIRS WEB
ALL ROUGH 04/20/2006 CANCELLED BY APPLICANT JMCGOWEN
Note: THIS IS A REINSPECTION
ALL ROUGH 04/19/2006 Disapproved -FEE REQUIRED JGIBSON
Note: Double top plate not to building code, missing approved plans, provide letter on truss connection of trusses to 2-ply girder over garage, service conductor wires not made up in panel.
ALL ROUGH 04/18/2006 CANCELLED BY APPLICANT JMCGOWEN
Note: THIS IS A REINSPECTION
ALL ROUGH 04/13/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: THIS IS A REINSPECTION 2x6 bearing wall overnotched, also need two top plates in same area, fire stop missing in range hood area
ALL ROUGH 04/11/2006 Disapproved -FEE REQUIRED ARAYMOND
Note: firestop missing, fireplace incomplete, shower drains incomplete
ALL ROUGH 04/10/2006 Disapproved -FEE REQUIRED ARAYMOND
Note: need aproved plans on job for inspection
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/10/2006 APPROVED ARAYMOND
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/07/2006 CANCELLED BY APPLICANT ARAYMOND
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/06/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: THIS IS A REINSPECTION many missed pourcells
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/05/2006 Disapproved -FEE REQUIRED ARAYMOND
Note: THIS IS A REINSPECTIONPREVIOUS NOTICE INCOMPLETE MISSED FILLED CELLS
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/04/2006 Disapproved -FEE REQUIRED ARAYMOND
Note: THIS IS A REINSPECTION fill cells incomplete
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/30/2006 Disapproved -FEE REQUIRED ARAYMOND
Note: missing fill cells
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/10/2006 Disapproved -FEE REQUIRED ARAYMOND
Note: THIS IS A REINSPECTION missed fill cells, truss plan does't match job
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/08/2006 CANCELLED BY APPLICANT DR
LINTEL 02/07/2006 APPROVED JMCGOWEN
FOUNDATION SURVEY APPROVED BY STORMWATER 02/02/2006 APPROVED - AS NOTED MBRENNAN
Note: FFE on foundation is 11.10'.....the proposed FFE was 9.88' Builder must submit another lot grading plan since the elevation deviated from the proposed FFE. 2/3/06...per MB from TC,,,same grading plan
MONOLITHIC SLAB INSPECTION/SLAB 01/26/2006 APPROVED JMCGOWEN
FIRST ROUGH PLUMBING INSPECTION 01/25/2006 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
FIRST ROUGH PLUMBING INSPECTION 01/24/2006 Disapproved -FEE REQUIRED ARAYMOND
Note: No construction documents on site.

Review History

Department Status Date In Date Out
BLD COMPLETE 04/26/2006 04/26/2006
Note: Released By: LWOODROME Revision: gas piping
BLD COMPLETE 04/20/2006 04/20/2006
Note: Released By: LWOODROME Revision: Connections at roof girder and truss
BLD COMPLETE 12/14/2005 12/16/2005
Note: Released By: CCOTE Approved for Release per plan cover sheet.
ZON COMPLETE 12/12/2005 12/14/2005
Note: Released By: HHERKERT
SW1 HOLD 12/02/2005 12/12/2005
Note: Held By: LAPTEKAR Need another sealed topo survey...stormwater needs 2 sealed ... Missing a lot grading profile for a salt water canal lot.
ZON HOLD 12/02/2005 12/12/2005
Note: Held By: HHERKERT landscape plan is required showing front foundation plantings as well as rear foundation plantings due to this lot backing a saltwater canal
SW1 COMPLETE 12/21/2005
Note: Released By: LAPTEKAR Grade profile and topo received

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤292.00 06/19/2006
EARLY POWER INSPECTION ¤40.00 06/19/2006
EARLY POWER INSPECTION ¤40.00 06/19/2006
REINSPECTION FEE ¤40.00 06/19/2006
REINSPECTION FEE ¤40.00 06/19/2006
REINSPECTION FEE ¤40.00 06/19/2006
REINSPECTION FEE ¤40.00 06/19/2006
REINSPECTION FEE ¤40.00 06/19/2006
REINSPECTION FEE ¤40.00 06/19/2006
REINSPECTION FEE ¤40.00 06/19/2006
REINSPECTION FEE ¤40.00 06/19/2006
REINSPECTION FEE ¤40.00 06/19/2006
REINSPECTION FEE ¤40.00 06/19/2006
REINSPECTION FEE ¤40.00 06/19/2006
REVISION ¤40.00 06/19/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 12/28/2005
STORM WATER PERMIT FEES ¤80.00 12/28/2005
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 12/28/2005
FIRE RES IMPACT FEE 4-1-05 ¤173.47 12/28/2005
MECHANICAL FEE ¤177.60 12/28/2005
PERMIT FEE ¤959.40 12/28/2005
PARKS IMPACT FEE 11-2-04 ¤1,120.91 12/28/2005
PLAN CHECK FEE ¤98.40 12/28/2005
PLUMBING FEE ¤177.60 12/28/2005
RADON FEE ¤17.17 12/28/2005
ADMIN FEE ¤20.00 12/28/2005
ARC HOUSE REVIEW ¤125.00 12/28/2005
BUILDING CODE ADMIN FUND ¤17.17 12/28/2005
ELECTRIC FEE ¤177.60 12/28/2005
Fees Total Due: ¤0.00 Total Paid: ¤10,844.83