I want to search for...
Permit #2005120169
Permit Details
Status: FINAL
| Parcel Id: 29-10-31-5540-01010-0220 |
| PATIO/DECK (NO ROOF) : 955 sqft |
| Total Square Footage: 1495 sqft |
| Block: 1010 |
| Subdivision: 1005 - SANCTUARY |
| Job Phone: (386) 775-1446 |
| Location Address: 1 DEVIN CT |
| Type: PO - POOL |
| Issue Date: 04/10/2006 |
| NOC: Unknown |
| Applicant name: BOB HERROLD |
| Owner: NORMAN & MARY BOTT |
|
Address 891 COUNTRY CLUB DRIVE PALM BEACH, FL 33408 |
| Lot: 0220 |
| Contracted Stated Job Value: ¤42,600.00 |
| Job Description: POOL AND 4' WHITE ALUMINUM FENCE |
| Type: CN |
Contractor
BOB HERROLDS ALL SEASONS SWIMMING POOLS & SPAS INC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
322 N DIXIE FREEWAY NEW SMYRNA BEACH , FL 32168 |
CPC019022 (Exp: 08/31/2020) | (386) 423-2330 | (386) 423-2333 |
Sub Contractors
JAMES ANTHONY PETRAS
| Status | Location Address | State License Number | Phone |
| CANCEL |
59 Azelia Road Debary, Fl., FL 32713 |
EC0002753 (Exp: 08/31/2018) | 386-804-1311 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL - FINAL | 03/20/2007 | FINAL APPROVED | RMARVEL |
| Note: Jim came in to schedule inspection | |||
| POOL - FINAL | 03/14/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: NEED TO HAVE RELIEF POP OFF VALVE. | |||
| STORMWATER FINAL INSPECTION | 02/28/2007 | APPROVED | DRANDALL |
| UTILITY COMPANY FINAL | 02/28/2007 | APPROVED | TSCHWEERS |
| POOL DECK INSPECTION | 08/22/2006 | APPROVED | KSAMPICO |
| LINTEL | 07/20/2006 | APPROVED | JMCGOWEN |
| Note: jessica call in from all seasons pool 3:52 on wenesday afternoon | |||
| RETAINING WALL FOUNDATION INSPECTION | 06/30/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION SCHEDULED A RETAINING WALL FOUNDATION INSPECTION FOR 6/30/06 AS PER THE CONTRACTOR | |||
| RETAINING WALL FOUNDATION INSPECTION | 06/29/2006 | CANCELLED BY APPLICANT | JGIBSON |
| STEEL & GROUND | 04/24/2006 | APPROVED | JMCGOWEN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/06/2006 | 04/07/2006 |
| Note: Released By: CCOTE Approved for Release. | |||
| ENGIN1 | COMPLETE | 03/29/2006 | 04/06/2006 |
| Note: Released By: KKRUGER See hold and notes on 1/13/2006 | |||
| ENGIN1 | COMPLETE | 12/09/2005 | 03/01/2006 |
| Note: Released By: KKRUGER Held By: KKRUGER Signed and sealed survey must be provided (2 copies). Survey must show the finished floor elevation for the house, and elevations at 10' interval along the rear yard drainage ditch. Elevations to be provided at existing top of slope, edge of drainage easement, and toe of slope along the west side of the drainage ditch. Retaining wall plan must be signed and sealed by a professional engineer with a valid Florida license. Retaining wall plan must show the wall to not encroach into the slope of the drainage ditch (proposed wall must be outside of the top of slope). The plan must show the proposed elevation for the top of the wall, and the proposed horizontal location. | |||
| ZON | COMPLETE | 12/06/2005 | 12/09/2005 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 03/19/2007 |
| RENEW PERMIT FEES | ¤40.00 | 02/23/2007 |
| ELECTRIC FEE | ¤58.80 | 04/10/2006 |
| PERMIT FEE | ¤288.00 | 04/10/2006 |