Permit #2005120182
Permit Details
Status: COED
| Parcel Id: 07-11-31-7057-00320-0080 |
| CONDITIONED SPACE: 2289 sqft |
| GARAGE: 431 sqft |
| OPENED PORCH (WITH ROOF) : 200 sqft |
| OPENED PORCH (WITH ROOF) : 48 sqft |
| Total Square Footage: 2968 sqft |
| Block: 0032 |
| Subdivision: - |
| Job Phone: (386) 445-7156 |
| Location Address: 7 UNDERMOUNT PATH W |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 12/21/2005 |
| NOC: RECORDED |
| Applicant name: JAMES WILLIAM KIRKSEY |
| Owner: MASTERPIECE HOME, INC. |
|
Address 4721 E. MOODY BLVD UNIT 5 BLDG 504 BUNNELL, FL 32110 |
| Lot: 080 |
| Contracted Stated Job Value: ¤126,311.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
Masterpiece Homes Inc. (Residential Contractor)
| Status | Location Address | Mailing Address | Phone | Fax |
| CANCEL |
4721 E MOODY BLVD BUNNELL, FL 32110 |
SUITE 504 BUNNELL, FL 32110 |
(386) 445-7156 | (386)445-7975 |
Sub Contractors
GLEN STEWART COLE
| Status | Location Address | State License Number | Phone | Fax |
| HOLD |
P. O. Box 1677 Palm Coast, FL 32136 |
EC0002522 (Exp: 08/31/2010) | (386) 437-4364 | (386)437-0412 |
MICHAEL DAVID CLARK
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Box 918 Bunnell, FL 32110 |
CAC044867 (Exp: 09/30/2008) | (386) 437-2001 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
DALE EARL MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2801 S. NOVA ROAD S. DAYTONA, FL 32119 |
CCC027435 (Exp: 08/31/2026) | 386-760-8240 | (386)756-2035 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 06/27/2006 | FINAL APPROVED | DROCKWELL |
| STORMWATER FINAL INSPECTION | 06/23/2006 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: Remove pile of tree limbs and brush on right sides remove construction debris ...wood bottles and cans and concrete chunks from neighboring properties sweep street clean for road damage assessments,.....photos taken | |||
| STORMWATER FINAL INSPECTION | 06/23/2006 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 06/21/2006 | APPROVED | TBEGTRUP |
| RESIDENTIAL EARLY POWER | 06/19/2006 | APPROVED | RMARVEL |
| PRE DRIVEWAY | 06/07/2006 | APPROVED - AS NOTED | GLALIMA |
| Note: ADJUSTING CULVERT PIPE | |||
| LATH /BRICK FLASHING | 05/23/2006 | APPROVED | DROCKWELL |
| INSULATION INSPECTION | 05/02/2006 | APPROVED | DROCKWELL |
| Note: Firecaulking must be used for draftstopping | |||
| ALL ROUGH | 04/26/2006 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 04/25/2006 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Must have water pressure | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/24/2006 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/11/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Need letter on front wall floor system noy per plan, repair porch header not breaking on bearing point, remove ply-wood from poarch area. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/10/2006 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: NOT READY. PARTIAL LIST FOLLOWS: 1) BRACING MISSING ON EXTERIOR END TRUSS OVER BEDROOM #3. 2) DAYLIGHT IS VISIBLE DUE TO MISSING SHEATHING BETWEEN END TRUSS NOTED ABOVE AND 3-PLY TRUSS T04. NOTE: SHEATHING SHOULD HAVE CONNECTING THE END TRUSS TO T04. 3) TRIANGLE KNEE WALL (EXTERIOR WALL), RIGHT SIDE OF GARAGE HAS INADEQUATE SHEER STRENGTH. 4) PORCH HEADER IS NOT BREAKING ON CENTER COLUMN. 5) T06 IS AT LEAST 1-1/2" OUT OF PLUMB AT THE RIGHT KINGS BEARING. 6) HTT16 IS NAILED TO T08 INSTEAD OF TT04 AS INTENDED. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/06/2006 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: THIS IS A REINSPECTION front wall and floor system not framed or anchored per plans, t19 missing brace, nail off t bracing 9" on center front and rear porches covered by osb cannot inspect, not ready | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/24/2006 | CANCELLED BY APPLICANT | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/17/2006 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Not ready for inspection | |||
| LINTEL | 03/08/2006 | APPROVED | DROCKWELL |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 03/07/2006 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 02/24/2006 | APPROVED | DROCKWELL |
| FIRST ROUGH PLUMBING INSPECTION | 02/23/2006 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| BLD | HOLD | 04/19/2006 | 04/19/2006 |
| Note: Held By: LWOODROME Revision: Beam(s) at rear porch PLAN REVIEW COMMENTS: " To verify that this proposed design change meets with the intent of 2004 Florida Building Code, section 2308.9.5.1, please provide the following information: " Provide construction detail(s) for a Glued Built Up member, as defined, per FBC, section 2302.1. " Specify adhesive to be used and fastening schedule per FBC, Table 2304.9. " Provide load calculations for the proposed built up member, which indicate that the member will meet or exceed the maximum spans allowed, per FBC, Table 2308.9.5. Larry Woodrome, CBO Chief Plans Examiner City of Palm Coast 386-986-3786 | |||
| BLD | COMPLETE | 04/18/2006 | 04/18/2006 |
| Note: Released By: LWOODROME Revision: Floor tuss detail | |||
| BLD | COMPLETE | 04/17/2006 | 04/26/2006 |
| Note: Released By: LWOODROME Revision; Beam @ rear porch | |||
| BLD | COMPLETE | 04/11/2006 | 04/13/2006 |
| Note: Released By: CCOTE Approved for Release. Revision: Changed floor system from 10" to 8". | |||
| SW1 | COMPLETE | 02/16/2006 | 02/17/2006 |
| Note: Released By: LAPTEKAR FFE is off | |||
| ZON | COMPLETE | 02/15/2006 | 02/16/2006 |
| Note: Released By: HHERKERT | |||
| BLD | COMPLETE | 12/13/2005 | 12/15/2005 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| SW1 | COMPLETE | 12/06/2005 | 12/12/2005 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 12/06/2005 | 12/13/2005 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 06/27/2006 |
| REINSPECTION FEE | ¤40.00 | 06/27/2006 |
| REINSPECTION FEE | ¤40.00 | 06/27/2006 |
| REINSPECTION FEE | ¤40.00 | 06/27/2006 |
| REINSPECTION FEE | ¤40.00 | 06/27/2006 |
| REINSPECTION FEE | ¤40.00 | 06/27/2006 |
| REINSPECTION FEE | ¤40.00 | 06/27/2006 |
| REVISION | ¤40.00 | 06/27/2006 |
| REVISION | ¤40.00 | 06/27/2006 |
| REVISION | ¤40.00 | 06/27/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 06/27/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 12/21/2005 |
| ADMIN FEE | ¤20.00 | 12/21/2005 |
| ARC HOUSE REVIEW | ¤125.00 | 12/21/2005 |
| BUILDING CODE ADMIN FUND | ¤14.84 | 12/21/2005 |
| ELECTRIC FEE | ¤162.00 | 12/21/2005 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 12/21/2005 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/21/2005 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 12/21/2005 |
| MECHANICAL FEE | ¤162.00 | 12/21/2005 |
| PERMIT FEE | ¤858.00 | 12/21/2005 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 12/21/2005 |
| PLAN CHECK FEE | ¤88.00 | 12/21/2005 |
| PLUMBING FEE | ¤162.00 | 12/21/2005 |
| RADON FEE | ¤14.84 | 12/21/2005 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,264.57 |