I want to search for...

Permit #2005120182

Permit Details

Status: COED

Parcel Id: 07-11-31-7057-00320-0080
CONDITIONED SPACE: 2289 sqft
GARAGE: 431 sqft
OPENED PORCH (WITH ROOF) : 200 sqft
OPENED PORCH (WITH ROOF) : 48 sqft
Total Square Footage: 2968 sqft
Block: 0032
Subdivision: -
Job Phone: (386) 445-7156
Location Address: 7 UNDERMOUNT PATH W
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/21/2005
NOC: RECORDED
Applicant name: JAMES WILLIAM KIRKSEY
Owner: MASTERPIECE HOME, INC.

Address

4721 E. MOODY BLVD UNIT 5 BLDG 504

BUNNELL, FL 32110

Lot: 080
Contracted Stated Job Value: ¤126,311.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

Masterpiece Homes Inc. (Residential Contractor)
Status Location Address Mailing Address Phone Fax
CANCEL

4721 E MOODY BLVD

BUNNELL, FL 32110

SUITE 504

BUNNELL, FL 32110

(386) 445-7156 (386)445-7975

Sub Contractors

GLEN STEWART COLE
Status Location Address State License Number Phone Fax
HOLD

P. O. Box 1677

Palm Coast, FL 32136

EC0002522 (Exp: 08/31/2010) (386) 437-4364 (386)437-0412
MICHAEL DAVID CLARK
Status Location Address State License Number Phone
CANCEL

P. O. Box 918

Bunnell, FL 32110

CAC044867 (Exp: 09/30/2008) (386) 437-2001
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
DALE EARL MARTIN
Status Location Address State License Number Phone Fax
ACTIVE

2801 S. NOVA ROAD

S. DAYTONA, FL 32119

CCC027435 (Exp: 08/31/2026) 386-760-8240 (386)756-2035

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 06/27/2006 FINAL APPROVED DROCKWELL
STORMWATER FINAL INSPECTION 06/23/2006 Disapproved -FEE REQUIRED GLALIMA
Note: Remove pile of tree limbs and brush on right sides remove construction debris ...wood bottles and cans and concrete chunks from neighboring properties sweep street clean for road damage assessments,.....photos taken
STORMWATER FINAL INSPECTION 06/23/2006 APPROVED GLALIMA
Note: THIS IS A REINSPECTION
UTILITY COMPANY FINAL 06/21/2006 APPROVED TBEGTRUP
RESIDENTIAL EARLY POWER 06/19/2006 APPROVED RMARVEL
PRE DRIVEWAY 06/07/2006 APPROVED - AS NOTED GLALIMA
Note: ADJUSTING CULVERT PIPE
LATH /BRICK FLASHING 05/23/2006 APPROVED DROCKWELL
INSULATION INSPECTION 05/02/2006 APPROVED DROCKWELL
Note: Firecaulking must be used for draftstopping
ALL ROUGH 04/26/2006 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ALL ROUGH 04/25/2006 Disapproved -FEE REQUIRED DROCKWELL
Note: Must have water pressure
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/24/2006 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/11/2006 Disapproved -FEE REQUIRED JGIBSON
Note: Need letter on front wall floor system noy per plan, repair porch header not breaking on bearing point, remove ply-wood from poarch area.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/10/2006 Disapproved -FEE REQUIRED PGALLMANN
Note: NOT READY. PARTIAL LIST FOLLOWS: 1) BRACING MISSING ON EXTERIOR END TRUSS OVER BEDROOM #3. 2) DAYLIGHT IS VISIBLE DUE TO MISSING SHEATHING BETWEEN END TRUSS NOTED ABOVE AND 3-PLY TRUSS T04. NOTE: SHEATHING SHOULD HAVE CONNECTING THE END TRUSS TO T04. 3) TRIANGLE KNEE WALL (EXTERIOR WALL), RIGHT SIDE OF GARAGE HAS INADEQUATE SHEER STRENGTH. 4) PORCH HEADER IS NOT BREAKING ON CENTER COLUMN. 5) T06 IS AT LEAST 1-1/2" OUT OF PLUMB AT THE RIGHT KINGS BEARING. 6) HTT16 IS NAILED TO T08 INSTEAD OF TT04 AS INTENDED.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/06/2006 Disapproved -FEE REQUIRED JHINDMAN
Note: THIS IS A REINSPECTION front wall and floor system not framed or anchored per plans, t19 missing brace, nail off t bracing 9" on center front and rear porches covered by osb cannot inspect, not ready
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/24/2006 CANCELLED BY APPLICANT JGIBSON
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/17/2006 Disapproved -FEE REQUIRED DROCKWELL
Note: Not ready for inspection
LINTEL 03/08/2006 APPROVED DROCKWELL
FOUNDATION SURVEY APPROVED BY STORMWATER 03/07/2006 APPROVED LAPTEKAR
MONOLITHIC SLAB INSPECTION/SLAB 02/24/2006 APPROVED DROCKWELL
FIRST ROUGH PLUMBING INSPECTION 02/23/2006 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
BLD HOLD 04/19/2006 04/19/2006
Note: Held By: LWOODROME Revision: Beam(s) at rear porch PLAN REVIEW COMMENTS: " To verify that this proposed design change meets with the intent of 2004 Florida Building Code, section 2308.9.5.1, please provide the following information: " Provide construction detail(s) for a Glued Built Up member, as defined, per FBC, section 2302.1. " Specify adhesive to be used and fastening schedule per FBC, Table 2304.9. " Provide load calculations for the proposed built up member, which indicate that the member will meet or exceed the maximum spans allowed, per FBC, Table 2308.9.5. Larry Woodrome, CBO Chief Plans Examiner City of Palm Coast 386-986-3786
BLD COMPLETE 04/18/2006 04/18/2006
Note: Released By: LWOODROME Revision: Floor tuss detail
BLD COMPLETE 04/17/2006 04/26/2006
Note: Released By: LWOODROME Revision; Beam @ rear porch
BLD COMPLETE 04/11/2006 04/13/2006
Note: Released By: CCOTE Approved for Release. Revision: Changed floor system from 10" to 8".
SW1 COMPLETE 02/16/2006 02/17/2006
Note: Released By: LAPTEKAR FFE is off
ZON COMPLETE 02/15/2006 02/16/2006
Note: Released By: HHERKERT
BLD COMPLETE 12/13/2005 12/15/2005
Note: Released By: CCOTE Approved for Release per plan cover sheet.
SW1 COMPLETE 12/06/2005 12/12/2005
Note: Released By: LAPTEKAR
ZON COMPLETE 12/06/2005 12/13/2005
Note: Released By: HHERKERT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 06/27/2006
REINSPECTION FEE ¤40.00 06/27/2006
REINSPECTION FEE ¤40.00 06/27/2006
REINSPECTION FEE ¤40.00 06/27/2006
REINSPECTION FEE ¤40.00 06/27/2006
REINSPECTION FEE ¤40.00 06/27/2006
REINSPECTION FEE ¤40.00 06/27/2006
REVISION ¤40.00 06/27/2006
REVISION ¤40.00 06/27/2006
REVISION ¤40.00 06/27/2006
STORMWATER REINSPECTION FEE ¤35.00 06/27/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 12/21/2005
ADMIN FEE ¤20.00 12/21/2005
ARC HOUSE REVIEW ¤125.00 12/21/2005
BUILDING CODE ADMIN FUND ¤14.84 12/21/2005
ELECTRIC FEE ¤162.00 12/21/2005
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 12/21/2005
STORM WATER PERMIT FEES ¤80.00 12/21/2005
FIRE RES IMPACT FEE 4-1-05 ¤173.47 12/21/2005
MECHANICAL FEE ¤162.00 12/21/2005
PERMIT FEE ¤858.00 12/21/2005
PARKS IMPACT FEE 11-2-04 ¤1,120.91 12/21/2005
PLAN CHECK FEE ¤88.00 12/21/2005
PLUMBING FEE ¤162.00 12/21/2005
RADON FEE ¤14.84 12/21/2005
Fees Total Due: ¤0.00 Total Paid: ¤10,264.57