I want to search for...
Permit #2005120618
Permit Details
Status: COED
| Parcel Id: 07-11-31-7035-00310-0100 |
| CONDITIONED SPACE: 1819 sqft |
| OPENED PORCH (WITH ROOF) : 67 sqft |
| GARAGE: 470 sqft |
| SCREEN PORCH (SOLID ROOF) : 146 sqft |
| Total Square Footage: 2502 sqft |
| Block: 0031 |
| Subdivision: - |
| Job Phone: (386) 672-8285 |
| Location Address: 51 BURNELL DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/12/2006 |
| NOC: RECORDED |
| Applicant name: JOSEPH TODD VANACORE |
| Owner: VALENTINE JAMES M SR & |
|
Address LILIA D CHICAGO, IL 60634 |
|
Address 3524 N NEW ENGLAND AVE CHICAGO, IL 60634 |
| Lot: 100 |
| Contracted Stated Job Value: ¤180,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
VANACORE CONSTRUCTION INC.
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
1451 N US HIGHWAY 1 Ormond Beach, FL 32174 |
SUITE 13 Ormond Beach, FL 32174 |
CBC058991 (Exp: 08/31/2024) | (386) 672-8285 |
Sub Contractors
TRENT MIHALIC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P.O. BOX 606 ZELWOOD, FL 32798 |
EC0003150 (Exp: 08/31/2012) | (321) 229-1241 | (386)698-2956 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
GREGORY A HAGEMAN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
545 Parque Drive Ormond Beach, FL 32174 |
CCC021394 (Exp: 08/31/2026) | (386) 672-2821 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 09/19/2006 | FINAL APPROVED | JLEVRAULT |
| STORMWATER FINAL INSPECTION | 09/15/2006 | APPROVED - AS NOTED | DRANDALL |
| Note: 33 sf road damage | |||
| DRIVEWAY | 09/06/2006 | APPROVED | DRANDALL |
| UTILITY COMPANY FINAL | 08/11/2006 | APPROVED | TSCHWEERS |
| DRIVEWAY | 08/01/2006 | APPROVED | DRANDALL |
| RESIDENTIAL EARLY POWER | 06/08/2006 | APPROVED | PGALLMANN |
| INSULATION INSPECTION | 04/17/2006 | APPROVED | MMOORE |
| LATH /BRICK FLASHING | 04/04/2006 | APPROVED | ARITTER |
| ALL ROUGH | 03/31/2006 | APPROVED | MMOORE |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/30/2006 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/28/2006 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: FILL CELL IN REAR - SIDE OF WINDOW. GROUT TRUSSES AT PERIMETER WHERE THEY ARE FLOATING IN AIR. HEADER STRAPS NOT INSTALLED PER PLAN DETAILS. REAR RIGHT CORNER - STRAP NAILED INTO OSB ONLY. REMOVE TAR PAPER FROM REAR PORCH GIRDER SO I CAN CHECK SPLICES. REMOVE TAR PAPER FROM FRONT ENTRANCE ARCHES AND PROVIDE INSPECTION HOLES TO CHECK ANCHORAGE. FRAMED WALL AT LEFT SIDE OF GARAGE NOT DONE TO PLAN - SHOULD BE A FULL LENGTH STUD TO ACCOMODATE CONTINUOUS LOAD PATH - HILITED ON PLAN. | |||
| LINTEL | 03/03/2006 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 03/02/2006 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: MISSING DOWEL ROD - HILITED ON PLAN. | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 02/28/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 02/22/2006 | APPROVED | JLEVRAULT |
| MONOLITHIC SLAB INSPECTION/SLAB | 02/21/2006 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: NOT READY. | |||
| FIRST ROUGH PLUMBING INSPECTION | 02/20/2006 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| FIRST ROUGH PLUMBING INSPECTION | 02/16/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. NO 5' OF HEAD PRESSURE 2. BURIED WATER PIPE ACROSS GARAGE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/03/2006 | 01/05/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R. | |||
| SW1 | COMPLETE | 12/21/2005 | 01/09/2006 |
| Note: Released By: WKINELL | |||
| ZON | COMPLETE | 12/21/2005 | 01/03/2006 |
| Note: Released By: ECOYNE |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤364.00 | 09/21/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 09/21/2006 |
| REINSPECTION FEE | ¤40.00 | 09/21/2006 |
| REINSPECTION FEE | ¤40.00 | 09/21/2006 |
| REINSPECTION FEE | ¤40.00 | 09/21/2006 |
| REINSPECTION FEE | ¤40.00 | 09/21/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 01/12/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/12/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 01/12/2006 |
| ADMIN FEE | ¤20.00 | 01/12/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 01/12/2006 |
| BUILDING CODE ADMIN FUND | ¤12.51 | 01/12/2006 |
| ELECTRIC FEE | ¤138.60 | 01/12/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 01/12/2006 |
| MECHANICAL FEE | ¤138.60 | 01/12/2006 |
| PERMIT FEE | ¤705.90 | 01/12/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 01/12/2006 |
| PLAN CHECK FEE | ¤72.40 | 01/12/2006 |
| PLUMBING FEE | ¤138.60 | 01/12/2006 |
| RADON FEE | ¤12.51 | 01/12/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,151.01 |