I want to search for...

Permit #2005120629

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-00350-0110
CONDITIONED SPACE: 1819 sqft
GARAGE: 470 sqft
OPENED PORCH (WITH ROOF) : 146 sqft
OPENED PORCH (WITH ROOF) : 67 sqft
Total Square Footage: 2502 sqft
Block: 0035
Subdivision: -
Job Phone: (386) 672-8285
Location Address: 1 LAMOYNE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/12/2006
NOC: RECORDED
Applicant name: JOSEPH TODD VANACORE
Owner: IBELLI STEPHEN F SR
Lot: 110
Contracted Stated Job Value: ¤180,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

VANACORE CONSTRUCTION INC.
Status Location Address Mailing Address State License Number Phone
INACTIVE

1451 N US HIGHWAY 1

Ormond Beach, FL 32174

SUITE 13

Ormond Beach, FL 32174

CBC058991 (Exp: 08/31/2024) (386) 672-8285

Sub Contractors

TRENT MIHALIC
Status Location Address State License Number Phone Fax
CANCEL

P.O. BOX 606

ZELWOOD, FL 32798

EC0003150 (Exp: 08/31/2012) (321) 229-1241 (386)698-2956
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
GREGORY A HAGEMAN
Status Location Address State License Number Phone
ACTIVE

545 Parque Drive

Ormond Beach, FL 32174

CCC021394 (Exp: 08/31/2026) (386) 672-2821

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 06/28/2006 FINAL APPROVED MMOORE
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 06/27/2006 Disapproved -FEE REQUIRED MMOORE
Note: THIS IS A REINSPECTION...........M. Bath outlet cover not flush with mirror
FINAL COMPLETE BUILDING INSPECTION 06/26/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. ARC SHEILD MISSING IN M. BATH OUTLET AT MIRROR
STORMWATER FINAL INSPECTION 06/20/2006 APPROVED - AS NOTED BFCHAMBERLAIN
Note: 25 s.f. road damage.....$300
UTILITY COMPANY FINAL 06/13/2006 APPROVED TSCHWEERS
Note: SCHEDULED A UTILITY CO. FINAL FOR 6/13/06 AS PER DAVE
RESIDENTIAL EARLY POWER 05/24/2006 APPROVED RMARVEL
RESIDENTIAL EARLY POWER 05/23/2006 Disapproved -FEE REQUIRED RMARVEL
Note: all loose romex must be boxed and secured.
DRIVEWAY 05/11/2006 APPROVED BFCHAMBERLAIN
INSULATION INSPECTION 03/30/2006 APPROVED MMOORE
LATH /BRICK FLASHING 03/23/2006 APPROVED MMOORE
ALL ROUGH 03/17/2006 APPROVED MMOORE
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/15/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/13/2006 Disapproved -FEE REQUIRED MMOORE
Note: THIS IS A REINSPECTION 1. TOP PLATE AT LEFT OF AC STAND TO HAVE 4' LAP FROM LAST SPLICE AT BOTTOM PLATE. NEW ADDED PLATE IS NOTCHED-OUT OVER 50% AT WIRES (LOOK AT BACK SIDE) 2. 2X12 AT AC HEADER NOT STRAPPED AT TOP AND BOTTOM 3. GARAGE DOOR KING STUDS NOT STRAPPED AT BOTTOM 4. T-O1, T-02 END STRAPS BENT AND NOT NAILED-OFF 5. FROM INSIDE OF BUILDING OVER MAIN ENTRY DOOR (ON RIGHT) 2X12 NEEDS END BOLT AND LAST TRUSS HANGER ON RIGHT SIDE OF TRUSS ISN'T NAILED TO ANYTHING SOLID 6. THESE ITEMS ADDRESSES BEFORE
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/08/2006 Disapproved -FEE REQUIRED JLEVRAULT
Note: THIS IS A REINSPECTION ITEMS 3, 5, 6, 7, AND 8 FROM LAST NON - COMPLIANCE STILL NOT DONE. SECOND REQUEST.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 02/27/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. T-09 LEFT I GARAGE BEFORE T-10 STRAP BENT UNDER TRUSS 2. T-10 / LEFT GARAGE THE FILLER BLOCK ON THE RIGHT SIDE NEEDS TO BE TAPCONNED THROUGH TO THE CONCRETE 3. GARAGE DOOR HEADER, A.C. HEADER NOT STRAPPED PER PLAN/ ALSO STUDS AT BOTTOM 4. GROUT TRUSSES WITH STONELESS GROUT 5. MASTER BATH T-01, T-02 STRAPS AT ENDS NOT NAILED-OFF PROPERLY---BENT 6. T-27 AT ENTRY END NOT NAILED (ON LEFT) FULLY INTO 2X12, 2X12 IS TOO SHORT 7. 2 MORE BOLTS NEEDED AT THIS 2X12, 1 MORE ON /AT EACH END 8. TOP PLATE OVER A.C. UNIT/ GARAGE 2X12 HEADER NEED PROPER LAP
LINTEL 02/17/2006 APPROVED MMOORE
LINTEL 02/16/2006 Disapproved -FEE REQUIRED JLEVRAULT
Note: MISSING DOWEL - CIRCLED ON PLANS.
FOUNDATION SURVEY APPROVED BY STORMWATER 02/15/2006 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 02/07/2006 APPROVED MMOORE
FIRST ROUGH PLUMBING INSPECTION 02/02/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
FIRST ROUGH PLUMBING INSPECTION 02/01/2006 Disapproved -FEE REQUIRED MMOORE
Note: NO PRESSURE ON VENTS 11:41 A.M.

Review History

Department Status Date In Date Out
BLD COMPLETE 01/04/2006 01/06/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet.
SW1 COMPLETE 12/21/2005 01/09/2006
Note: Released By: WKINELL
ZON COMPLETE 12/21/2005 01/04/2006
Note: Released By: DCHAUDOIN

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤300.00 07/06/2006
EARLY POWER INSPECTION ¤40.00 07/06/2006
EARLY POWER INSPECTION ¤40.00 07/06/2006
REINSPECTION FEE ¤40.00 07/06/2006
REINSPECTION FEE ¤40.00 07/06/2006
REINSPECTION FEE ¤40.00 07/06/2006
REINSPECTION FEE ¤40.00 07/06/2006
REINSPECTION FEE ¤40.00 07/06/2006
REINSPECTION FEE ¤40.00 07/06/2006
REINSPECTION FEE ¤40.00 07/06/2006
REINSPECTION FEE ¤40.00 07/06/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 01/12/2006
STORM WATER PERMIT FEES ¤80.00 01/12/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 01/12/2006
FIRE RES IMPACT FEE 4-1-05 ¤173.47 01/12/2006
MECHANICAL FEE ¤138.60 01/12/2006
PERMIT FEE ¤705.90 01/12/2006
PARKS IMPACT FEE 11-2-04 ¤1,120.91 01/12/2006
PLAN CHECK FEE ¤72.40 01/12/2006
PLUMBING FEE ¤138.60 01/12/2006
RADON FEE ¤12.51 01/12/2006
ADMIN FEE ¤20.00 01/12/2006
ARC HOUSE REVIEW ¤125.00 01/12/2006
BUILDING CODE ADMIN FUND ¤12.51 01/12/2006
ELECTRIC FEE ¤138.60 01/12/2006
Fees Total Due: ¤0.00 Total Paid: ¤10,287.01