I want to search for...
Permit #2005120629
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-00350-0110 |
| CONDITIONED SPACE: 1819 sqft |
| GARAGE: 470 sqft |
| OPENED PORCH (WITH ROOF) : 146 sqft |
| OPENED PORCH (WITH ROOF) : 67 sqft |
| Total Square Footage: 2502 sqft |
| Block: 0035 |
| Subdivision: - |
| Job Phone: (386) 672-8285 |
| Location Address: 1 LAMOYNE LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/12/2006 |
| NOC: RECORDED |
| Applicant name: JOSEPH TODD VANACORE |
| Owner: IBELLI STEPHEN F SR |
| Lot: 110 |
| Contracted Stated Job Value: ¤180,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
VANACORE CONSTRUCTION INC.
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
1451 N US HIGHWAY 1 Ormond Beach, FL 32174 |
SUITE 13 Ormond Beach, FL 32174 |
CBC058991 (Exp: 08/31/2024) | (386) 672-8285 |
Sub Contractors
TRENT MIHALIC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P.O. BOX 606 ZELWOOD, FL 32798 |
EC0003150 (Exp: 08/31/2012) | (321) 229-1241 | (386)698-2956 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
GREGORY A HAGEMAN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
545 Parque Drive Ormond Beach, FL 32174 |
CCC021394 (Exp: 08/31/2026) | (386) 672-2821 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 06/28/2006 | FINAL APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 06/27/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: THIS IS A REINSPECTION...........M. Bath outlet cover not flush with mirror | |||
| FINAL COMPLETE BUILDING INSPECTION | 06/26/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. ARC SHEILD MISSING IN M. BATH OUTLET AT MIRROR | |||
| STORMWATER FINAL INSPECTION | 06/20/2006 | APPROVED - AS NOTED | BFCHAMBERLAIN |
| Note: 25 s.f. road damage.....$300 | |||
| UTILITY COMPANY FINAL | 06/13/2006 | APPROVED | TSCHWEERS |
| Note: SCHEDULED A UTILITY CO. FINAL FOR 6/13/06 AS PER DAVE | |||
| RESIDENTIAL EARLY POWER | 05/24/2006 | APPROVED | RMARVEL |
| RESIDENTIAL EARLY POWER | 05/23/2006 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: all loose romex must be boxed and secured. | |||
| DRIVEWAY | 05/11/2006 | APPROVED | BFCHAMBERLAIN |
| INSULATION INSPECTION | 03/30/2006 | APPROVED | MMOORE |
| LATH /BRICK FLASHING | 03/23/2006 | APPROVED | MMOORE |
| ALL ROUGH | 03/17/2006 | APPROVED | MMOORE |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/15/2006 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/13/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: THIS IS A REINSPECTION 1. TOP PLATE AT LEFT OF AC STAND TO HAVE 4' LAP FROM LAST SPLICE AT BOTTOM PLATE. NEW ADDED PLATE IS NOTCHED-OUT OVER 50% AT WIRES (LOOK AT BACK SIDE) 2. 2X12 AT AC HEADER NOT STRAPPED AT TOP AND BOTTOM 3. GARAGE DOOR KING STUDS NOT STRAPPED AT BOTTOM 4. T-O1, T-02 END STRAPS BENT AND NOT NAILED-OFF 5. FROM INSIDE OF BUILDING OVER MAIN ENTRY DOOR (ON RIGHT) 2X12 NEEDS END BOLT AND LAST TRUSS HANGER ON RIGHT SIDE OF TRUSS ISN'T NAILED TO ANYTHING SOLID 6. THESE ITEMS ADDRESSES BEFORE | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/08/2006 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: THIS IS A REINSPECTION ITEMS 3, 5, 6, 7, AND 8 FROM LAST NON - COMPLIANCE STILL NOT DONE. SECOND REQUEST. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/27/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. T-09 LEFT I GARAGE BEFORE T-10 STRAP BENT UNDER TRUSS 2. T-10 / LEFT GARAGE THE FILLER BLOCK ON THE RIGHT SIDE NEEDS TO BE TAPCONNED THROUGH TO THE CONCRETE 3. GARAGE DOOR HEADER, A.C. HEADER NOT STRAPPED PER PLAN/ ALSO STUDS AT BOTTOM 4. GROUT TRUSSES WITH STONELESS GROUT 5. MASTER BATH T-01, T-02 STRAPS AT ENDS NOT NAILED-OFF PROPERLY---BENT 6. T-27 AT ENTRY END NOT NAILED (ON LEFT) FULLY INTO 2X12, 2X12 IS TOO SHORT 7. 2 MORE BOLTS NEEDED AT THIS 2X12, 1 MORE ON /AT EACH END 8. TOP PLATE OVER A.C. UNIT/ GARAGE 2X12 HEADER NEED PROPER LAP | |||
| LINTEL | 02/17/2006 | APPROVED | MMOORE |
| LINTEL | 02/16/2006 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: MISSING DOWEL - CIRCLED ON PLANS. | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 02/15/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 02/07/2006 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 02/02/2006 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| FIRST ROUGH PLUMBING INSPECTION | 02/01/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: NO PRESSURE ON VENTS 11:41 A.M. |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/04/2006 | 01/06/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| SW1 | COMPLETE | 12/21/2005 | 01/09/2006 |
| Note: Released By: WKINELL | |||
| ZON | COMPLETE | 12/21/2005 | 01/04/2006 |
| Note: Released By: DCHAUDOIN |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤300.00 | 07/06/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 07/06/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 07/06/2006 |
| REINSPECTION FEE | ¤40.00 | 07/06/2006 |
| REINSPECTION FEE | ¤40.00 | 07/06/2006 |
| REINSPECTION FEE | ¤40.00 | 07/06/2006 |
| REINSPECTION FEE | ¤40.00 | 07/06/2006 |
| REINSPECTION FEE | ¤40.00 | 07/06/2006 |
| REINSPECTION FEE | ¤40.00 | 07/06/2006 |
| REINSPECTION FEE | ¤40.00 | 07/06/2006 |
| REINSPECTION FEE | ¤40.00 | 07/06/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 01/12/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/12/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 01/12/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 01/12/2006 |
| MECHANICAL FEE | ¤138.60 | 01/12/2006 |
| PERMIT FEE | ¤705.90 | 01/12/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 01/12/2006 |
| PLAN CHECK FEE | ¤72.40 | 01/12/2006 |
| PLUMBING FEE | ¤138.60 | 01/12/2006 |
| RADON FEE | ¤12.51 | 01/12/2006 |
| ADMIN FEE | ¤20.00 | 01/12/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 01/12/2006 |
| BUILDING CODE ADMIN FUND | ¤12.51 | 01/12/2006 |
| ELECTRIC FEE | ¤138.60 | 01/12/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,287.01 |