Permit #2005120661
Permit Details
Status: COED
| Parcel Id: 07-11-31-7059-00710-0020 |
| CONDITIONED SPACE: 1585 sqft |
| GARAGE: 441 sqft |
| OPENED PORCH (WITH ROOF) : 205 sqft |
| OPENED PORCH (WITH ROOF) : 47 sqft |
| Total Square Footage: 2278 sqft |
| Block: 0071 |
| Subdivision: - |
| Job Phone: (386)439-2062 |
| Location Address: 3 SLATE BLUE PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/06/2006 |
| NOC: RECORDED |
| Applicant name: JAMES CARTWRIGHT HOPE |
| Owner: CORNERSTONE CUSTOM HOMES INC |
|
Address 3 SLATE BLUE PLACE PALM COAST, FL 32164 |
| Lot: 020 |
| Contracted Stated Job Value: ¤12,000.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
Cornerstone Custom Homes, Inc. (Residential Contra
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P. O. Box 730384 Ormond Beach, FL 32173 |
CRC046828 (Exp: 09/30/2008) | (386)439-2062 | (386)439-2419 |
Sub Contractors
JOHN RENTON
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P. O. Box 1726 New Smyrna Beach, 32168 |
EC0002679 (Exp: 08/31/2014) | (386)423-9314 | (386)000-0000 |
LARRY MILTON HISS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1315 A LPGA BLVD Holly Hill, FL 32117 |
CAC032450 (Exp: 08/31/2018) | (386) 672-8688 | (386)238-8688 |
ALFERD MITCHUM FUTCH
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1218 San Jose Blvd Holly Hill, FL 32117 |
CFC044175 (Exp: 08/31/2012) | (386) 672-3576 | (386)672-0107 |
MARCUS DIMILLO
| Status | Location Address | Phone |
| CANCEL |
P.O. BOX 1048 BUNNELL, FL 32110 |
(386)437-4068 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 09/15/2006 | FINAL APPROVED | KSAMPICO |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 09/14/2006 | Disapproved -FEE REQUIRED | KSAMPICO |
| Note: NEEDS TO MOVE A/C DISCONNECT AND MISSING ONE SHADED TREE. | |||
| LATH /BRICK FLASHING | 09/13/2006 | APPROVED | LWOODROME |
| Note: Letter from architect Richard Brookfield for missed inspection of lath | |||
| STORMWATER FINAL INSPECTION | 09/13/2006 | APPROVED - AS NOTED | GLALIMA |
| Note: ROAD DAMAGE 40 FEET = 420.00 | |||
| STORMWATER FINAL INSPECTION | 09/08/2006 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: SOD REAR , AND RAAR RIGHT , THEN SEED AND STRAW RIGHT , REAR , LEFT . ONLY AFTER YOU PICK UP ALL TRASH . SWEEP ALL ROAD AND RE PAIR CULVERT ENDS . 46 ' FEET OF ROAD REPAIR = 468.00 | |||
| UTILITY COMPANY FINAL | 09/07/2006 | APPROVED | MBACON |
| RESIDENTIAL EARLY POWER | 08/21/2006 | APPROVED | DROCKWELL |
| PRE DRIVEWAY | 08/02/2006 | APPROVED | GLALIMA |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 07/21/2006 | APPROVED | WKINELL |
| INSULATION INSPECTION | 06/19/2006 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 06/16/2006 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Draftstop dryer vent/Top plate laundry room 2x6 wall-Draftstop wiring | |||
| TEMPORARY POLE | 06/12/2006 | APPROVED | DROCKWELL |
| ALL ROUGH | 06/12/2006 | APPROVED | DROCKWELL |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/17/2006 | APPROVED | DROCKWELL |
| LINTEL | 04/17/2006 | APPROVED | CMINI |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 04/13/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 03/20/2006 | APPROVED | DROCKWELL |
| FIRST ROUGH PLUMBING INSPECTION | 03/09/2006 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 09/11/2006 | 09/13/2006 |
| Note: Released By: LWOODROME Architets letter RE: MISSED LATH INSPECTION | |||
| SW1 | HOLD | 07/20/2006 | 07/20/2006 |
| Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy. Please submit revised sealed surveys for this property. We check the surveys by comparison to the city's as-built drawings. The elevations at the centerlines of the road perpendicular to the property lines are interpolated in reference to the NATIONAL GEODETIC VERTIVAL DATUM of 1929 (NGVD 1929). By applying the datum shift supplied by the VERTCON utility program for this location, expected elevations are derived relative to the NORTH AMERICAN VERTICAL DATUM of 1988 (NAVD 1988). (Note: VERTCON data is in meters and must be converted to feet by dividing by 0.3048) The derived elevations are in substantial disagreement with the data supplied on the surveys. We take into account that actual elevations may be higher than originally designed by a margin of several inches due to subsequent road paving operations but are not expected to be lower. The survey appears to be referenced to the NGVD of 1929 not NAVD of 1988. | |||
| BLD | COMPLETE | 06/12/2006 | 06/13/2006 |
| Note: Released By: LWOODROME Revision: Energy calculations | |||
| BLD | COMPLETE | 01/27/2006 | 01/30/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R. | |||
| BLD | HOLD | 01/09/2006 | 01/18/2006 |
| Note: Held By: FREODICA 1. Update all General Notes, Specifications and other notes to reference to the current code version and sections. The current code version is the 2004 Florida Building Code - Residential (FRC 2004). 2. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 3. Indicate how attic access will be constructed to comply with FRC Section R309.2. 4. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC Section 309.1.1. 5. Provide bond beam transition detail (change in plate height elevation). 6. Revise lintel schedule to show specific type of pre cast concrete "cast-crete" to be used over each window/door openings including porch and garage. The load values shown on schedule do not match with "cast-crete" catalog. CITY OF PALM COAST o 2 COMMERCE BLVD o PALM COAST, FL 32164 PHONE: 386-986-3780 o FAX: 386-986-3781 *The City is also requesting that there is a 6" x 6" area on the cover page (first drawing sheet) for City comments and approval stamp. | |||
| ZON | COMPLETE | 01/06/2006 | 01/06/2006 |
| Note: Released By: HHERKERT | |||
| URB | COMPLETE | 01/06/2006 | 01/09/2006 |
| Note: Released By: CGOEWEY | |||
| SW1 | HOLD | 12/22/2005 | 01/13/2006 |
| Note: Held By: LAPTEKAR <issing a few sealed copies of the topo survey...need 3 sealed copies. The lot grading plan needs to show proposed elevations next to the existing elevation of the topo ...not contour grading lines. | |||
| ZON | HOLD | 12/22/2005 | 01/05/2006 |
| Note: Held By: DCHAUDOIN NEED LOT AREA ON SURVEY | |||
| SW1 | COMPLETE | 01/18/2006 | |
| Note: Released By: LAPTEKAR new lot grading plan received | |||
| SW1 | COMPLETE | 07/21/2006 | |
| Note: Released By: WKINELL Received new topo surveys/LGPs. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 09/14/2006 |
| REINSPECTION FEE | ¤40.00 | 09/13/2006 |
| REVISION | ¤40.00 | 09/13/2006 |
| MISCELLANEOUS | ¤40.00 | 09/13/2006 |
| ENGINEERING ROAD DAMAGE | ¤420.00 | 09/13/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 09/13/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 09/13/2006 |
| SW REVISION | ¤40.00 | 09/13/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 02/06/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 02/06/2006 |
| MECHANICAL FEE | ¤126.60 | 02/06/2006 |
| ADMIN FEE | ¤20.00 | 02/06/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 02/06/2006 |
| BUILDING CODE ADMIN FUND | ¤11.39 | 02/06/2006 |
| ELECTRIC FEE | ¤126.60 | 02/06/2006 |
| PERMIT FEE | ¤627.90 | 02/06/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 02/06/2006 |
| PLAN CHECK FEE | ¤64.40 | 02/06/2006 |
| PLUMBING FEE | ¤126.60 | 02/06/2006 |
| RADON FEE | ¤11.39 | 02/06/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 02/06/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 02/06/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,157.77 |