Permit #2005120696

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00420-0100
CONDITIONED SPACE: 3730 sqft
GARAGE: 1203 sqft
SCREEN PORCH (SOLID ROOF) : 306 sqft
SCREEN PORCH (SOLID ROOF) : 531 sqft
OPENED PORCH (WITH ROOF) : 57 sqft
Total Square Footage: 5827 sqft
Block: 0042
Subdivision: -
Job Phone: (386) 445-4747
Location Address: 5 WHITE HOLLY PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/10/2006
NOC: RECORDED
Applicant name: WILLIAM VALENTINE GROFF
Owner: MOSCO LEN &

Address

IRENE H&W

BEACHWOOD, NJ 08722

Address

816 SUNSET ROAD

BEACHWOOD, NJ 08722

Lot: 100
Contracted Stated Job Value: ¤395,000.00
Job Description: REISDENTIAL SINGLE FAMILY HOME
Type: CN

Contractor

COUNTRY CLUB HOMES OF FLORIDA, INC.
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

4440 N. Oceanshore Blvd

Palm Coast, FL 32137

SUITE 101

Palm Coast, FL 32137

CRC043737 (Exp: 08/31/2012) (386) 445-4747 (386)445-5955

Sub Contractors

STEVEN DUANE DENSLOW
Status Location Address State License Number Phone Fax
CANCEL

400 N. US # 1

Ormond Beach, FL 32174

EC0001678 (Exp: 08/31/2012) (386) 672-8494 (386)673-7856
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
GARY S WELBORN
Status Location Address State License Number Phone Fax
CANCEL

1709 North Nova Road

Holly Hill, FL 32117

CFC037140 (Exp: 08/31/2018) (386) 257-1172 (386)252-5979
WAYNE STEED
Status Location Address State License Number Phone
CANCEL

318 N. PINE AVENUE

IVERNESS, FL 34450

CCC058299 (Exp: 08/31/2010) (352)637-2422

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 12/11/2006 FINAL APPROVED JMCGOWEN
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 12/08/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: switches in master bed need to be on arc-fault, add outlets in kitchen counter top, fix micro outlet, need egress light installed at garage, fill holes in ceiling at garage, need 30" between a/c condensers, need cleanout plug installed
STORMWATER FINAL INSPECTION 12/08/2006 APPROVED DRANDALL
Note: road repaired
UTILITY COMPANY FINAL 12/05/2006 APPROVED MBACON
Note: FAILED PER U-83 UTILITY PANEL NEEDS TO RE REPLACED THIS IS A REINSPECTION
UTILITY COMPANY FINAL 12/01/2006 Disapproved - NO FEE TSCHWEERS
Note: FAILED, CONDUIT AND WIRES WERE CUT AND PULLED OUT OF PANEL
STORMWATER FINAL INSPECTION 11/29/2006 APPROVED - AS NOTED DRANDALL
Note: THIS IS A REINSPECTION 32 sf road damage ROAD DAMAGE REPAIRED BY BUILDER
STORMWATER FINAL INSPECTION 11/22/2006 Disapproved -FEE REQUIRED DRANDALL
Note: remove dumpster.....place sod in left adj. property swale.....straw & seed exposed earth on left, left rear, & right side.....place sod on exposed earth rear, along drainage ditch.....remove concrete mixer from right adj. property.....remove trash from right side by dumpster.....32 sf road damage $ 356.00
RESIDENTIAL EARLY POWER 11/08/2006 APPROVED LHITES
Note: THIS IS A REINSPECTION
RESIDENTIAL EARLY POWER 10/25/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: NEED TO CAP AND SEAL ALL EXPOSED WIRES AT VACCUM LINES.
PRE DRIVEWAY 10/23/2006 APPROVED DRANDALL
INSULATION INSPECTION 07/24/2006 APPROVED ARITTER
ALL ROUGH 07/11/2006 APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
ALL ROUGH 07/07/2006 Disapproved -FEE REQUIRED JLEVRAULT
Note: NO PRESSURE ON WATER LINES. FOUR PLY TRUSS D-55 NOT BOLTED PER PLAN AND NOT STRAPPED WITH PROPER UPLIFT CONNECTORS.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 07/05/2006 APPROVED ARITTER
Note: THIS IS A REINSPECTION
TEMPORARY POLE 07/05/2006 APPROVED ARITTER
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 05/24/2006 CANCELLED BY APPLICANT PGALLMANN
LINTEL 04/07/2006 APPROVED JLEVRAULT
FOUNDATION SURVEY APPROVED BY STORMWATER 04/06/2006 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 03/15/2006 APPROVED JLEVRAULT
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB INSPECTION/SLAB 03/14/2006 CANCELLED BY APPLICANT JLEVRAULT
FIRST ROUGH PLUMBING INSPECTION 03/10/2006 CANCELLED BY INSPECTOR JLEVRAULT
FIRST ROUGH PLUMBING INSPECTION 03/09/2006 APPROVED JLEVRAULT

Review History

Department Status Date In Date Out
BLD COMPLETE 02/09/2006 02/09/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 02/07/2006 02/08/2006
Note: Held By: CCOTE The Truss Uplift and Support Schedule submitted is an excellent example; however additional clarification regarding some of the connectors specified must be submitted in order to complete the Building Permit Application plan review. 1. Please provide clarification regarding the truss uplift and support schedule that was submitted on 2/07/2006 per the following comments. a. Based on the plan review detail 5/S2.1 was considered to be the typical roof truss to cmu connection detail. This detail shows a single top plate that conflicts with detail 6/S2.1 and other notes found on the drawings referring to a double top plate. Please clarify where double and single top plates are to be located. If double top plates are to be located everywhere then submit two copies of a signed and sealed revised detail 5/S2.1. b. Some of the trusses bearing on the exterior masonry walls have an H8 connector as the primary or alternate connector specified. Please clarify how this will be installed with a single top plate. The Simpson literature that I have reviewed identifies the use of a double top plate with this connector. c. Some of the trusses bearing on the exterior masonry walls have an HTS20 connector specified. Clarify how this will be installed with a single top plate. The Simpson literature that I have reviewed identifies an alternate connector for connecting wood to masonry (HTSM20) with much lower uplift values. Is it your intent to wrap the top plate, if so will this require attachment to the underside of the top plate prior to the top plate installation? Or, is it your intent to fasten to the face of the top plate and the face of the masonry wall? Please provide a detail showing how the connector is to be installed as well as the location and type of fasteners to be used.
BLD HOLD 01/30/2006 01/31/2006
Note: Held By: CCOTE The City has reviewed your comments regarding 5 White Holly Place. Please submit revised drawings/items that address the following items in order for the City to complete the Building Permit Application plan review. Item Number 6 & 9 require additional information/clarification as follows: Item#6: Engineer response states that connectors to be used are referenced on sheet 12/S2.0 for truss to masonry wall connectors and S1.1 uplift connector schedule for frame walls. Both of these items only contain generic connector information. The City requires project specific connectors to be identified on the drawings. Please provide a project specific truss connector schedule listing each truss and connector to be used for each point of connection for each truss designation. Truss Connector Schedule must be signed and sealed by the design professional. Item #8: Engineer response indicated LVL to post connectors and stated that not LVL to LVL connectors other than those listed on the drawings were required. This leaves the connection at the outside corner of the Cabana unclear since there are two LVL's coming together over a 5 ½" column. Please verify that the column will provide adequate bearing and that the LVL's will not be connected together. In addition, please clarify whether the LVL's shown at the Cabana are continuous over intermediate columns or if the LVL's span from column to column; if column to column respond to attachment and bearing issue at shared column. Please contact me with any questions. ------------------------------------------------- Carl L. Cote, R.A. Senior Plans Examiner City of Palm Coast - Building Department 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-4753 [fax]: (386) 986-3781 [email]: ccote@ci.palm-coast.fl.us -------------------------------------------------
BLD HOLD 01/13/2006 01/22/2006
Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. 1. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 2. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 3. Indicate how attic access will be constructed to comply with FRC Section R309.2. 4. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0. 5. Provide bond beam transition detail. 6. Sheet S0.1 indicates truss connectors to use for 1 and 2 ply trusses, howver the truss layout indicates that there are some 3 and 4 ply trusses. Please provide connectors to use for these trusses as well. 7. Sheet S1.0 contains some detail marks referencing detail 4M/S2.0, however this detail could not be found on sheet S2.0. Please provide detail. 8. Sheet S1.1 indicates some of the LVL and Beam connectors to be used. Please indicate all connectors for each beam and LVL connection/intersection (LVL to LVL, LVL to Post, LVL to CMU, Beam to Post). 9. Sheet S1.1 has details 1/S1.1 and 2/S1.1 however there are no references to these details on the plan. Either add detail marks on plan as to where they apply, if they are not to be used then remove. 10. Sheet S1.1 has a reference of LB-1 on the plan for some of the masonry openings. What is LB-1? 11. Provide lintel type, sizes, filled/unfilled, reinforcing type size and number to be used for all masonry openings. 12. Sheet S2.0, S2.1, S3.0, S4.0: Remove all details that do not apply to this specific project.
SW1 HOLD 12/27/2005 01/19/2006
Note: Held By: WKINELL Need to show NAVD 1988 benchmark on lot grading plan. Identify location of benchmark on hydrant. (i.e., bottom flange, X, etc.) Show hydrant on lot grading plan. Hydrant must be 7 ft minimum away from driveway. Hydrant requires 7 ft minimum clear area. Need to show more interior proposed elevations indicating stormwater flow from rear to front. Without more interior proposed elevations, stormwater appears to flow onto adjacent lots.
ZON COMPLETE 12/27/2005 01/13/2006
Note: Released By: ECOYNE
SW1 COMPLETE 01/30/2006
Note: Released By: WKINELL New lot grading plan received and reviewed.\\wk

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 12/11/2006
EARLY POWER INSPECTION ¤40.00 12/11/2006
REINSPECTION FEE ¤40.00 12/11/2006
REINSPECTION FEE ¤40.00 12/11/2006
REINSPECTION FEE ¤40.00 12/11/2006
STORMWATER REINSPECTION FEE ¤35.00 12/11/2006
STORMWATER REINSPECTION FEE ¤35.00 12/11/2006
UTILITIES DAMAGE BACKCHARGE ¤630.19 12/11/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 02/10/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 02/10/2006
STORM WATER PERMIT FEES ¤80.00 02/10/2006
ADMIN FEE ¤20.00 02/10/2006
ARC HOUSE REVIEW ¤125.00 02/10/2006
BUILDING CODE ADMIN FUND ¤29.14 02/10/2006
ELECTRIC FEE ¤267.00 02/10/2006
FIRE RES IMPACT FEE 4-1-05 ¤173.47 02/10/2006
MECHANICAL FEE ¤267.00 02/10/2006
PERMIT FEE ¤1,540.50 02/10/2006
PARKS IMPACT FEE 11-2-04 ¤1,120.91 02/10/2006
PLAN CHECK FEE ¤158.00 02/10/2006
PLUMBING FEE ¤267.00 02/10/2006
RADON FEE ¤29.14 02/10/2006
Fees Total Due: ¤0.00 Total Paid: ¤11,825.86