Permit #2005120728

Permit Details

Status: COED

Parcel Id: 15-11-31-2835-00000-0080
CONDITIONED SPACE: 4328 sqft
GARAGE: 695 sqft
OPENED PORCH (WITH ROOF) : 591 sqft
OPENED PORCH (WITH ROOF) : 585 sqft
OPENED PORCH (WITH ROOF) : 50 sqft
Total Square Footage: 6249 sqft
Block: 00000
Subdivision: 1075 - FRONT STREET @ GRAND HAVEN PH5
Job Phone: (386) 445-4408
Location Address: 89 FRONT ST
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/14/2006
NOC: RECORDED
Applicant name: PATRICK E KOLLAR
Owner: LYNN JEFFREY G & KATHY H&W

Address

71 NORTH MAIN ST.

CLARKSTON, MI 48346

Lot: 0080
Contracted Stated Job Value: ¤650,000.00
Job Description: SINGLE FAMILY HOME
Type: CN

Contractor

RED CARPET CONSTRUCTION INC.
Status Location Address State License Number Phone Fax
ACTIVE

8A Market Place Court

Palm Coast, FL 32137

CRC017457 (Exp: 08/31/2026) (386) 445-4408 (386)446-2232

Sub Contractors

BEN K REIHL
Status Location Address State License Number Phone Fax
ACTIVE

605 MCINTOSH ROAD

Ormond Beach, 32174

EC0002867 (Exp: 08/31/2026) (386) 677-4464 386-673-4199
LARRY MILTON HISS
Status Location Address State License Number Phone Fax
CANCEL

1315 A LPGA BLVD

Holly Hill, FL 32117

CAC032450 (Exp: 08/31/2018) (386) 672-8688 (386)238-8688
BARRY D MARTIN
Status Location Address State License Number Phone Fax
CANCEL

1650 N STATE STREET

Bunnell, FL 32110

CCC033728 (Exp: 08/31/2020) (386) 437-7700 (386)437-7701
GARY S WELBORN
Status Location Address State License Number Phone Fax
CANCEL

1709 North Nova Road

Holly Hill, FL 32117

CFC037140 (Exp: 08/31/2018) (386) 257-1172 (386)252-5979
LEONARD E GASPARY
Status Location Address Phone Fax
INACTIVE

400 NORTH US HWY #1

ORMOND BEACH, FL 32174

(386)672-8494 (386)673-7856
STEVEN DUANE DENSLOW
Status Location Address State License Number Phone Fax
CANCEL

400 N. US # 1

Ormond Beach, FL 32174

EC0001678 (Exp: 08/31/2012) (386) 672-8494 (386)673-7856

Inspection History

Type Request Date Result Inspector
ELECTRICAL FINAL 09/13/2007 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
GAS FINAL 09/13/2007 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 09/13/2007 FINAL APPROVED JGIBSON
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 09/12/2007 Disapproved - NO FEE JGIBSON
Note: CANCLED BY CONTRACTOR
GAS FINAL 09/12/2007 Disapproved - NO FEE JGIBSON
Note: CANCLED BY CONTRACTOR
ELECTRICAL FINAL 09/12/2007 Disapproved - NO FEE RMARVEL
Note: CANCELLED BY GC
STORMWATER FINAL INSPECTION 09/10/2007 APPROVED DRANDALL
UTILITY COMPANY FINAL 09/04/2007 APPROVED RDRIGGERS
Note: PER RICK DRIGGERS IT IS OK TO PASS THIS IS A REINSPECTION
UTILITY COMPANY FINAL 08/22/2007 Disapproved - NO FEE CBOEHME
Note: FAILED INCORRECT SEWER HOOK UP THIS IS A REINSPECTION
UTILITY COMPANY FINAL 07/31/2007 Disapproved - NO FEE TSCHWEERS
Note: No 6" sewer clean out
RESIDENTIAL EARLY POWER 05/24/2007 APPROVED MMOORE
INSULATION INSPECTION 02/05/2007 APPROVED JMCGOWEN
Note: THIS IS A REINSPECTION
INSULATION INSPECTION 02/01/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: NOT READY-INSULATION. ELECTRICAL WIRES ARE OK
GAS ROUGH 01/30/2007 CANCELLED BY APPLICANT JMCGOWEN
ALL ROUGH 01/30/2007 APPROVED - AS NOTED JMCGOWEN
Note: THIS IS A REINSPECTION NEED 1 1/4" CLEARANCE OF NM FROM FRAMING MEMBER OVER REAR SLIDERS
GAS ROUGH 01/29/2007 APPROVED JMCGOWEN
Note: Red carpet called in to schedule a gas rough for 1/29/07
ALL ROUGH 01/19/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: need bushuing on pvc. strap nm cable every 4.5ft. need a gas rough. need a bond wire at the spa motor. need a anti-scald valve on the spray valve. terminater fresh air vent on fire place. remove nm from housing of recessed cans. THIS IS A REINSPECTION
ALL ROUGH 12/28/2006 CANCELLED BY APPLICANT JGIBSON
Note: THIS IS A REINSPECTION
ALL ROUGH 12/21/2006 CANCELLED BY APPLICANT JMCGOWEN
ALL ROUGH 12/20/2006 CANCELLED BY APPLICANT AIRS WEB
LATH /BRICK FLASHING 10/26/2006 APPROVED JGIBSON
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/26/2006 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/20/2006 CANCELLED BY APPLICANT JGIBSON
Note: Canceled by JOHN MORGAN FROM RED CARPET.
RESIDENTIAL EARLY POWER 10/11/2006 APPROVED LHITES
LINTEL 06/15/2006 APPROVED JMCGOWEN
Note: THIS IS A REINSPECTION
LINTEL 06/07/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: need header detail and schedule
FLOOD ZONE 'A' ELEVATION CERTIFICATE APPROVAL 06/06/2006 APPROVED CBENTLEY
MONOLITHIC SLAB INSPECTION/SLAB 05/16/2006 APPROVED CMINI
FIRST ROUGH PLUMBING INSPECTION 05/09/2006 APPROVED JGIBSON

Review History

Department Status Date In Date Out
BLD COMPLETE 07/25/2007 07/25/2007
Note: Released By: CCOTE REVISION: Add generator to permit. (electric only)
ZON COMPLETE 07/03/2007 07/25/2007
Note: Released By: ECOYNE Held By: JGONZALEZ submitted a conditional approval letter. need to see approved landscaping plan for generator.
ZON HOLD 06/21/2007 06/26/2007
Note: Held By: JGONZALEZ need setback information and/ or approval letter from grand haven allowing you to have it easemenrt
BLD COMPLETE 06/12/2006 06/13/2006
Note: Released By: LWOODROME Revision: Lintel details and schedule
BLD REJECT 03/02/2006 03/07/2006
Note: Rejected By: CCOTE "Or equal" is not sufficient. Need to submit items to be considered as equals.
BLD COMPLETE 02/06/2006 02/09/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 01/23/2006 01/30/2006
Note: Held By: CCOTE The City has received your comments however the items were not addressed, not clearly addressed or needed additional clarification. Please submit revised drawings/items that address the following items in order for the City to complete the Building Permit Application plan review. Old items that have been completed are shown in strikethrough and new comments are in bold italic. 1. The drawings contain two interior bearing wall details, one on A9 and one on S1. They are different clarify if both are to be used and if so denote locations on plan. Also, the foundation plan indicates anchor bolt spacing that only matches on of the sections. 2. Provide sizes of all Beams on a signed and sealed drawing. Only Beam 1 was signed and sealed. All beam size sheets must be signed and sealed or preferred method would be to list beam sizes on a signed and sealed drawing. 3. Provide connectors for all beams on a signed and sealed drawing. Connectors for beams 6, 7 & 8 were not submitted, provide connector information. 4. Show floor framing members on framing plan for exterior floor structure at angled porch area; refer to 2nd floor plan. Indicate additional beam(s) and connector(s) to be used. 5. The 2nd floor roof framing plan indicates a 2x12 header to support angled roof at rear porch area. Indicate connector(s) to be used to secure to beam 6 & 8. 6. Some of the code references are incorrect. Please correct electrical Code, current is NEC 2002. 7. The floor plan indicates that all lintels will be 8F24-1B/1T however this will not work at all locations based on the elevations (arch windows, garage door) and the floor plan indicates other lintels. Please clearly indicate specific lintel types/sizes/reinforcing to be used all masonry openings. 8. Detail 8 on A3 references a Beam 7 which is incorrect. 9. 2nd floor plan has a section marker referencing 4/A8 which does not exist. 10. Sheet A10 indicates roof areas to be framed by Builder. Please provide framing type, size, and connectors/fasteners/anchoring to be used to secure to wall/trusses. 11. Sheet S3 references Florida Building Code 2002 which is incorrect. Not corrected, provide revised drawing. 12. Provide size of Header by builder for header shown on A10 adjacent to T32. 13. Indicate all connectors to be used including but not limited to F20 to BM3; T40-43 to BM1; F24 to BM5; ……. 14. Provide detail for raised floor area at Office. Stair detail and Detail at exterior wall. Not corrected, provide details.
BLD HOLD 01/12/2006 01/19/2006
Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. The drawings contain two interior bearing wall details, one on A9 and one on S1. They are different clarify if both are to be used and if so denote locations on plan. Also, the foundation plan indicates anchor bolt spacing that only matches on of the sections. 2. Provide sizes of all Beams on a signed and sealed drawing. 3. Provide connectors for all beams on a signed and sealed drawing. 4. Show floor framing members on framing plan for exterior floor structure at angled porch area; refer to 2nd floor plan. Indicate additional beam(s) and connector(s) to be used. 5. The 2nd floor roof framing plan indicates a 2x12 header to support angled roof at rear porch area. Indicate connector(s) to be used to secure to beam 6 & 8. 6. Some of the code references are incorrect. Please correct electrical Code, current is NEC 2002. 7. The floor plan indicates that all lintels will be 8F24-1B/1T however this will not work at all locations based on the elevations (arch windows, garage door) and the floor plan indicates other lintels. Please clearly indicate specific lintel types/sizes/reinforcing to be used all masonry openings. 8. Detail 8 on A3 references a Beam 7 which is incorrect. 9. 2nd floor plan has a section marker referencing 4/A8 which does not exist. 10. Sheet A10 indicates roof areas to be framed by Builder. Please provide framing type, size, and connectors/fasteners/anchoring to be used to secure to wall/trusses. 11. Sheet S3 references Florida Building Code 2002 which is incorrect. 12. Provide size of Header by builder for header shown on A10 adjacent to T32. 13. Indicate all connectors to be used including but not limited to F20 to BM3; T40-43 to BM1; F24 to BM5; ……. 14. Provide detail for raised floor area at Office. Stair detail and Detail at exterior wall.
URB COMPLETE 01/11/2006 01/12/2006
Note: Released By: CGOEWEY
PLFM COMPLETE 01/11/2006 01/23/2006
Note: Released By: CBENTLEY elevation Certificate received
SW1 COMPLETE 12/27/2005 01/24/2006
Note: Released By: LAPTEKAR
ZON COMPLETE 12/27/2005 01/11/2006
Note: Released By: HHERKERT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 09/14/2007
EARLY POWER INSPECTION ¤40.00 09/14/2007
ADDITIONAL FEE ¤40.00 09/14/2007
REINSPECTION FEE ¤40.00 09/14/2007
REINSPECTION FEE ¤40.00 09/14/2007
REINSPECTION FEE ¤40.00 09/14/2007
REVISION ¤40.00 09/14/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 03/14/2006
STORM WATER PERMIT FEES ¤80.00 03/14/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 03/14/2006
ADMIN FEE ¤20.00 03/14/2006
BUILDING CODE ADMIN FUND ¤31.25 03/14/2006
ELECTRIC FEE ¤420.00 03/14/2006
FIRE RES IMPACT FEE 4-1-05 ¤173.47 03/14/2006
MECHANICAL FEE ¤420.00 03/14/2006
PERMIT FEE ¤2,535.00 03/14/2006
PARKS IMPACT FEE 11-2-04 ¤1,120.91 03/14/2006
PLAN CHECK FEE ¤260.00 03/14/2006
PLUMBING FEE ¤420.00 03/14/2006
RADON FEE ¤31.25 03/14/2006
Fees Total Due: ¤0.00 Total Paid: ¤12,640.39