| Parcel Id: 15-11-31-2835-00000-0080 |
| CONDITIONED SPACE: 4328 sqft |
| GARAGE: 695 sqft |
| OPENED PORCH (WITH ROOF) : 591 sqft |
| OPENED PORCH (WITH ROOF) : 585 sqft |
| OPENED PORCH (WITH ROOF) : 50 sqft |
| Total Square Footage: 6249 sqft |
| Block: 00000 |
| Subdivision: 1075 - FRONT STREET @ GRAND HAVEN PH5 |
| Job Phone: (386) 445-4408 |
| Location Address: 89 FRONT ST |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/14/2006 |
| NOC: RECORDED |
| Applicant name: PATRICK E KOLLAR |
| Owner: LYNN JEFFREY G & KATHY H&W |
|
Address 71 NORTH MAIN ST. CLARKSTON, MI 48346 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤650,000.00 |
| Job Description: SINGLE FAMILY HOME |
| Type: CN |
Contractor
RED CARPET CONSTRUCTION INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
8A Market Place Court Palm Coast, FL 32137 |
CRC017457 (Exp: 08/31/2026) | (386) 445-4408 | (386)446-2232 |
Sub Contractors
BEN K REIHL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
605 MCINTOSH ROAD Ormond Beach, 32174 |
EC0002867 (Exp: 08/31/2026) | (386) 677-4464 | 386-673-4199 |
LARRY MILTON HISS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1315 A LPGA BLVD Holly Hill, FL 32117 |
CAC032450 (Exp: 08/31/2018) | (386) 672-8688 | (386)238-8688 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
GARY S WELBORN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1709 North Nova Road Holly Hill, FL 32117 |
CFC037140 (Exp: 08/31/2018) | (386) 257-1172 | (386)252-5979 |
LEONARD E GASPARY
| Status | Location Address | Phone | Fax |
| INACTIVE |
400 NORTH US HWY #1 ORMOND BEACH, FL 32174 |
(386)672-8494 | (386)673-7856 |
STEVEN DUANE DENSLOW
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. US # 1 Ormond Beach, FL 32174 |
EC0001678 (Exp: 08/31/2012) | (386) 672-8494 | (386)673-7856 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRICAL FINAL | 09/13/2007 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| GAS FINAL | 09/13/2007 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 09/13/2007 | FINAL APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 09/12/2007 | Disapproved - NO FEE | JGIBSON |
| Note: CANCLED BY CONTRACTOR | |||
| GAS FINAL | 09/12/2007 | Disapproved - NO FEE | JGIBSON |
| Note: CANCLED BY CONTRACTOR | |||
| ELECTRICAL FINAL | 09/12/2007 | Disapproved - NO FEE | RMARVEL |
| Note: CANCELLED BY GC | |||
| STORMWATER FINAL INSPECTION | 09/10/2007 | APPROVED | DRANDALL |
| UTILITY COMPANY FINAL | 09/04/2007 | APPROVED | RDRIGGERS |
| Note: PER RICK DRIGGERS IT IS OK TO PASS THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 08/22/2007 | Disapproved - NO FEE | CBOEHME |
| Note: FAILED INCORRECT SEWER HOOK UP THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 07/31/2007 | Disapproved - NO FEE | TSCHWEERS |
| Note: No 6" sewer clean out | |||
| RESIDENTIAL EARLY POWER | 05/24/2007 | APPROVED | MMOORE |
| INSULATION INSPECTION | 02/05/2007 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 02/01/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: NOT READY-INSULATION. ELECTRICAL WIRES ARE OK | |||
| GAS ROUGH | 01/30/2007 | CANCELLED BY APPLICANT | JMCGOWEN |
| ALL ROUGH | 01/30/2007 | APPROVED - AS NOTED | JMCGOWEN |
| Note: THIS IS A REINSPECTION NEED 1 1/4" CLEARANCE OF NM FROM FRAMING MEMBER OVER REAR SLIDERS | |||
| GAS ROUGH | 01/29/2007 | APPROVED | JMCGOWEN |
| Note: Red carpet called in to schedule a gas rough for 1/29/07 | |||
| ALL ROUGH | 01/19/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: need bushuing on pvc. strap nm cable every 4.5ft. need a gas rough. need a bond wire at the spa motor. need a anti-scald valve on the spray valve. terminater fresh air vent on fire place. remove nm from housing of recessed cans. THIS IS A REINSPECTION | |||
| ALL ROUGH | 12/28/2006 | CANCELLED BY APPLICANT | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 12/21/2006 | CANCELLED BY APPLICANT | JMCGOWEN |
| ALL ROUGH | 12/20/2006 | CANCELLED BY APPLICANT | AIRS WEB |
| LATH /BRICK FLASHING | 10/26/2006 | APPROVED | JGIBSON |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/26/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/20/2006 | CANCELLED BY APPLICANT | JGIBSON |
| Note: Canceled by JOHN MORGAN FROM RED CARPET. | |||
| RESIDENTIAL EARLY POWER | 10/11/2006 | APPROVED | LHITES |
| LINTEL | 06/15/2006 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 06/07/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: need header detail and schedule | |||
| FLOOD ZONE 'A' ELEVATION CERTIFICATE APPROVAL | 06/06/2006 | APPROVED | CBENTLEY |
| MONOLITHIC SLAB INSPECTION/SLAB | 05/16/2006 | APPROVED | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 05/09/2006 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 07/25/2007 | 07/25/2007 |
| Note: Released By: CCOTE REVISION: Add generator to permit. (electric only) | |||
| ZON | COMPLETE | 07/03/2007 | 07/25/2007 |
| Note: Released By: ECOYNE Held By: JGONZALEZ submitted a conditional approval letter. need to see approved landscaping plan for generator. | |||
| ZON | HOLD | 06/21/2007 | 06/26/2007 |
| Note: Held By: JGONZALEZ need setback information and/ or approval letter from grand haven allowing you to have it easemenrt | |||
| BLD | COMPLETE | 06/12/2006 | 06/13/2006 |
| Note: Released By: LWOODROME Revision: Lintel details and schedule | |||
| BLD | REJECT | 03/02/2006 | 03/07/2006 |
| Note: Rejected By: CCOTE "Or equal" is not sufficient. Need to submit items to be considered as equals. | |||
| BLD | COMPLETE | 02/06/2006 | 02/09/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | HOLD | 01/23/2006 | 01/30/2006 |
| Note: Held By: CCOTE The City has received your comments however the items were not addressed, not clearly addressed or needed additional clarification. Please submit revised drawings/items that address the following items in order for the City to complete the Building Permit Application plan review. Old items that have been completed are shown in strikethrough and new comments are in bold italic. 1. The drawings contain two interior bearing wall details, one on A9 and one on S1. They are different clarify if both are to be used and if so denote locations on plan. Also, the foundation plan indicates anchor bolt spacing that only matches on of the sections. 2. Provide sizes of all Beams on a signed and sealed drawing. Only Beam 1 was signed and sealed. All beam size sheets must be signed and sealed or preferred method would be to list beam sizes on a signed and sealed drawing. 3. Provide connectors for all beams on a signed and sealed drawing. Connectors for beams 6, 7 & 8 were not submitted, provide connector information. 4. Show floor framing members on framing plan for exterior floor structure at angled porch area; refer to 2nd floor plan. Indicate additional beam(s) and connector(s) to be used. 5. The 2nd floor roof framing plan indicates a 2x12 header to support angled roof at rear porch area. Indicate connector(s) to be used to secure to beam 6 & 8. 6. Some of the code references are incorrect. Please correct electrical Code, current is NEC 2002. 7. The floor plan indicates that all lintels will be 8F24-1B/1T however this will not work at all locations based on the elevations (arch windows, garage door) and the floor plan indicates other lintels. Please clearly indicate specific lintel types/sizes/reinforcing to be used all masonry openings. 8. Detail 8 on A3 references a Beam 7 which is incorrect. 9. 2nd floor plan has a section marker referencing 4/A8 which does not exist. 10. Sheet A10 indicates roof areas to be framed by Builder. Please provide framing type, size, and connectors/fasteners/anchoring to be used to secure to wall/trusses. 11. Sheet S3 references Florida Building Code 2002 which is incorrect. Not corrected, provide revised drawing. 12. Provide size of Header by builder for header shown on A10 adjacent to T32. 13. Indicate all connectors to be used including but not limited to F20 to BM3; T40-43 to BM1; F24 to BM5; ……. 14. Provide detail for raised floor area at Office. Stair detail and Detail at exterior wall. Not corrected, provide details. | |||
| BLD | HOLD | 01/12/2006 | 01/19/2006 |
| Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. The drawings contain two interior bearing wall details, one on A9 and one on S1. They are different clarify if both are to be used and if so denote locations on plan. Also, the foundation plan indicates anchor bolt spacing that only matches on of the sections. 2. Provide sizes of all Beams on a signed and sealed drawing. 3. Provide connectors for all beams on a signed and sealed drawing. 4. Show floor framing members on framing plan for exterior floor structure at angled porch area; refer to 2nd floor plan. Indicate additional beam(s) and connector(s) to be used. 5. The 2nd floor roof framing plan indicates a 2x12 header to support angled roof at rear porch area. Indicate connector(s) to be used to secure to beam 6 & 8. 6. Some of the code references are incorrect. Please correct electrical Code, current is NEC 2002. 7. The floor plan indicates that all lintels will be 8F24-1B/1T however this will not work at all locations based on the elevations (arch windows, garage door) and the floor plan indicates other lintels. Please clearly indicate specific lintel types/sizes/reinforcing to be used all masonry openings. 8. Detail 8 on A3 references a Beam 7 which is incorrect. 9. 2nd floor plan has a section marker referencing 4/A8 which does not exist. 10. Sheet A10 indicates roof areas to be framed by Builder. Please provide framing type, size, and connectors/fasteners/anchoring to be used to secure to wall/trusses. 11. Sheet S3 references Florida Building Code 2002 which is incorrect. 12. Provide size of Header by builder for header shown on A10 adjacent to T32. 13. Indicate all connectors to be used including but not limited to F20 to BM3; T40-43 to BM1; F24 to BM5; ……. 14. Provide detail for raised floor area at Office. Stair detail and Detail at exterior wall. | |||
| URB | COMPLETE | 01/11/2006 | 01/12/2006 |
| Note: Released By: CGOEWEY | |||
| PLFM | COMPLETE | 01/11/2006 | 01/23/2006 |
| Note: Released By: CBENTLEY elevation Certificate received | |||
| SW1 | COMPLETE | 12/27/2005 | 01/24/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 12/27/2005 | 01/11/2006 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 09/14/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 09/14/2007 |
| ADDITIONAL FEE | ¤40.00 | 09/14/2007 |
| REINSPECTION FEE | ¤40.00 | 09/14/2007 |
| REINSPECTION FEE | ¤40.00 | 09/14/2007 |
| REINSPECTION FEE | ¤40.00 | 09/14/2007 |
| REVISION | ¤40.00 | 09/14/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 03/14/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/14/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 03/14/2006 |
| ADMIN FEE | ¤20.00 | 03/14/2006 |
| BUILDING CODE ADMIN FUND | ¤31.25 | 03/14/2006 |
| ELECTRIC FEE | ¤420.00 | 03/14/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 03/14/2006 |
| MECHANICAL FEE | ¤420.00 | 03/14/2006 |
| PERMIT FEE | ¤2,535.00 | 03/14/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 03/14/2006 |
| PLAN CHECK FEE | ¤260.00 | 03/14/2006 |
| PLUMBING FEE | ¤420.00 | 03/14/2006 |
| RADON FEE | ¤31.25 | 03/14/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤12,640.39 |