I want to search for...
Permit #2005120730
Permit Details
Status: COED
| Parcel Id: 07-11-31-7024-00030-0270 |
| CONDITIONED SPACE: 1726 sqft |
| GARAGE: 508 sqft |
| SCREEN PORCH (SOLID ROOF) : 308 sqft |
| OPENED PORCH (WITH ROOF) : 66 sqft |
| Total Square Footage: 2608 sqft |
| Block: 0003 |
| Subdivision: - |
| Job Phone: (386)931-0468 |
| Location Address: 4 PRINCESS ROSE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/24/2006 |
| NOC: RECORDED |
| Applicant name: ERIC ALLEN |
| Owner: ALLEN, ERIC & ALLEN, DANIEL |
|
Address 7 BELLAIRE CIRCLE PALM COAST, FL 32137 |
| Lot: 270 |
| Contracted Stated Job Value: ¤130,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
ALLEN HOMES & CONSTRUCTION INC.
| Status | Location Address | State License Number | Phone |
| CANCEL |
18 FORGE LANE PALM COAST, FL 32137 |
CGC1505654 (Exp: 08/31/2014) | 386-931-0468 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 08/23/2006 | FINAL APPROVED | ARITTER |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 08/17/2006 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: 1) A/C CONDENSER TOO CLOSE TO BUILDING WALL. 2) NO ACCESS TO WHIRLPOOL PUMP MOTOR. 3) NO GFCI PROTECTION TO WHIRLPOOL MOTOR WAS OBSERVED AT TIME OF INSPECTION. 4) EXPOSED ROMEX CABLE IN LAUNDRY ROOM. 5) RECEPTACLE MISSING ON BACKSIDE OF KITCHEN COUNTER. | |||
| FINAL COMPLETE BUILDING INSPECTION | 08/16/2006 | CANCELLED BY APPLICANT | ARITTER |
| Note: by contractor | |||
| STORMWATER FINAL INSPECTION | 08/14/2006 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION 0 ROAD DAMAGES | |||
| UTILITY COMPANY FINAL | 07/28/2006 | APPROVED | TREESE |
| STORMWATER FINAL INSPECTION | 07/27/2006 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: CLEAN OUT CULVERT ENDS , CONCRETE , . THEN REMOVE ALL TRASH . IN BACK YOU NEED A 4 TO 1 SLOPE , SEED AND STRAW . clean road for road damage assessment | |||
| DRIVEWAY | 07/13/2006 | APPROVED | DRANDALL |
| LATH /BRICK FLASHING | 05/04/2006 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 04/28/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: This job has went past lath inspection. | |||
| INSULATION INSPECTION | 04/28/2006 | APPROVED | JGIBSON |
| ALL ROUGH | 04/26/2006 | APPROVED | PGALLMANN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/07/2006 | APPROVED | ARAYMOND |
| LINTEL | 03/10/2006 | APPROVED | TOUTLAND |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 03/07/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 02/21/2006 | APPROVED | ARAYMOND |
| FIRST ROUGH PLUMBING INSPECTION | 02/16/2006 | APPROVED | PGALLMANN |
| TEMPORARY POLE | 02/02/2006 | APPROVED | ARAYMOND |
| Note: LIBBY - SUSAN - 8:15 -- 2-3-06 |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 07/10/2006 | 07/10/2006 |
| Note: Released By: LAPTEKAR changing driveway back to a straight driveway | |||
| SW1 | COMPLETE | 02/02/2006 | 02/02/2006 |
| Note: Released By: LAPTEKAR adding a circualr driveway | |||
| BLD | COMPLETE | 01/13/2006 | 01/22/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| SW1 | COMPLETE | 12/27/2005 | 01/24/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | HOLD | 12/27/2005 | 01/10/2006 |
| Note: Held By: ECOYNE Model home hold for ARC meeting 0l/13/06 | |||
| ZON | COMPLETE | 01/13/2006 | |
| Note: Released By: ECOYNE |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 01/02/2007 |
| REINSPECTION FEE | ¤40.00 | 01/02/2007 |
| REVISION | ¤40.00 | 01/02/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 01/02/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 01/24/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 01/24/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/24/2006 |
| ADMIN FEE | ¤20.00 | 01/24/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 01/24/2006 |
| BUILDING CODE ADMIN FUND | ¤13.04 | 01/24/2006 |
| ELECTRIC FEE | ¤136.80 | 01/24/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 01/24/2006 |
| MECHANICAL FEE | ¤136.80 | 01/24/2006 |
| PERMIT FEE | ¤694.20 | 01/24/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 01/24/2006 |
| PLAN CHECK FEE | ¤71.20 | 01/24/2006 |
| PLUMBING FEE | ¤136.80 | 01/24/2006 |
| RADON FEE | ¤13.04 | 01/24/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,724.77 |