I want to search for...
Permit #2005120811
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7037-01520-0020 |
| PATIO/DECK (NO ROOF) : 653 sqft |
| Total Square Footage: 1092 sqft |
| Block: 0152 |
| Subdivision: 0 - |
| Job Phone: (386)517-0582 |
| Location Address: 14 LEMAY PL |
| Type: PO - POOL |
| Issue Date: 01/23/2006 |
| NOC: RECORDED |
| Applicant name: JAMES EDEN |
| Owner: PEREZ MARIO & |
|
Address LUCY RODRIGUEZ CARTERET, NJ 07008 |
| Lot: 020 |
| Job Description: POOL AND SCREEN ENCLOSURE |
| Type: CN |
Contractor
POOLS N SPAS OF CENTRAL FLORIDA, INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
50 AUDUBON LANE , |
CPC035660 (Exp: 08/31/2012) | 386-527-1795 | 386-269-0495 |
Sub Contractors
DARIN KEITH COURINGTON
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2032 ANNE CIRCLE SOUTH DAYTONA, FL 32119 |
EC13002231 (Exp: 08/31/2012) | (386)566-6464 | 000-000-0000 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL - FINAL | 09/28/2006 | FINAL APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION CONTRACTOR CALLED TO SCHEDULE A POOL FINAL FOR 9/28/06 | |||
| POOL - FINAL | 09/19/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: THIS IS A REINSPECTION 1. page 1-43/ cable attachment brackets at bottom (foundation or edge of slab), to be in the same alignment/ plane as per plan | |||
| POOL - FINAL | 08/04/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. PAGE 1-43 BOTTOM ANCHOR PLATE NOT THE SAME ANGLE AS CABLE IN PLACES, SOME ONLY HAVE 1 BOLT AT BOTTOM 2. ONE CABLE LOSE 3. REVISION FOR ALL AREAS NOT PER PLAN (SEE YELLOW) 4. SPRINKLER HEAD AT VENT LEFT OF POOL SPA SPRAYING WATER UP AND INSIDE VENT...MOVE SPRINKLERS HEAD | |||
| POOL - FINAL | 07/07/2006 | CANCELLED BY APPLICANT | AIRS WEB |
| ENGINEERING FINAL | 05/26/2006 | CANCELLED BY INSPECTOR | LAPTEKAR |
| Note: this already passed a stormwater final 5/19/06 | |||
| UTILITY COMPANY FINAL | 05/24/2006 | APPROVED | TSCHWEERS |
| Note: per phil from pools n spas | |||
| STORMWATER FINAL INSPECTION | 05/19/2006 | APPROVED | DSCHRAGER |
| POOL DECK INSPECTION | 03/14/2006 | APPROVED | MMOORE |
| STEEL & GROUND | 02/07/2006 | APPROVED | MMOORE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 09/13/2006 | 09/18/2006 |
| Note: Released By: CCOTE Approved for Release. REVISION: Revised screen beam sizes. | |||
| BLD | COMPLETE | 01/05/2006 | 01/18/2006 |
| Note: Released By: LWOODROME | |||
| ZON | COMPLETE | 12/29/2005 | 01/05/2006 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 09/20/2006 |
| REVISION | ¤40.00 | 09/18/2006 |
| REINSPECTION FEE | ¤40.00 | 08/08/2006 |
| ARC POOL/SCREEN REVIEW | ¤50.00 | 01/23/2006 |
| ELECTRIC FEE | ¤46.20 | 01/23/2006 |
| PERMIT FEE | ¤162.00 | 01/23/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤378.20 |