I want to search for...
Permit #2005120829
Permit Details
Status: COED
| Parcel Id: 07-11-31-7014-00020-0990 |
| CONDITIONED SPACE: 3082 sqft |
| GARAGE: 789 sqft |
| OPENED PORCH (WITH ROOF) : 391 sqft |
| OPENED PORCH (WITH ROOF) : 60 sqft |
| Total Square Footage: 4322 sqft |
| Block: 0002 |
| Subdivision: - |
| Job Phone: (386) 445-5239 |
| Location Address: 7 COTTONWOOD CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/01/2006 |
| NOC: RECORDED |
| Applicant name: KEITH M PARKER |
| Owner: JENNINGS NATHANIEL & |
|
Address DELORES C H&W PALM COAST, FL 32135 |
|
Address PO BOX 350336 PALM COAST, FL 32135 |
| Lot: 990 |
| Contracted Stated Job Value: ¤298,500.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
DILLARD CONSTRUCTION LLC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 355007 PALM COAST, FL 32137 |
CGC1510399 (Exp: 09/30/2010) | 386-864-1320 | (386)986-3054 |
Sub Contractors
DANIEL R SHEFFIELD
| Status | Location Address | State License Number | Phone |
| INACTIVE |
1100 Old Haw Creek Road Bunnell, FL 32110 |
EC0003100 (Exp: 08/31/2024) | 386-931-4729 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
MARTIN JOHN EVANS
| Status | Location Address | State License Number |
| ACTIVE |
14 FORT CAROLINE CT BUNNELL, FL 32110 |
CFC057676 (Exp: 08/31/2026) |
MILLARD K KELLER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
313 S. VOLUSIA AVENUE DELAND, FL 32724 |
CCC1325778 (Exp: 08/31/2010) | (386) 774-9961 | (386)774-2388 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 12/15/2006 | FINAL APPROVED | ACOOPER |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 12/14/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: THIS IS A REINSPECTION rec. by kitchen sink needs to be within 2ft. arc shields needed throughout house. incandescent fixture in clothes closet needs to clear shelf by 12in. all outlets in bedrooms need to be AFCI. need a smoke detector outside all bedrooms. | |||
| FINAL COMPLETE BUILDING INSPECTION | 12/12/2006 | Disapproved - NO FEE | JMCGOWEN |
| Note: JACKIE FROM DILLARD CALLED TO SCHEDULE A FINAL INSPECTION ON 12/12/06 inspection stopped by the gc. gas was not ready. | |||
| RESIDENTIAL EARLY POWER | 12/05/2006 | APPROVED | LHITES |
| UTILITY COMPANY FINAL | 11/16/2006 | APPROVED | TSCHWEERS |
| STORMWATER FINAL INSPECTION | 11/14/2006 | APPROVED - AS NOTED | DRANDALL |
| Note: 44 sf road damage | |||
| UTILITY COMPANY FINAL | 11/13/2006 | APPROVED | TSCHWEERS |
| DRIVEWAY | 10/03/2006 | APPROVED | DRANDALL |
| LATH /BRICK FLASHING | 09/15/2006 | APPROVED | ACOOPER |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 09/12/2006 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: Not reaqdy for inspection. | |||
| INSULATION INSPECTION | 08/15/2006 | APPROVED | KSAMPICO |
| ALL ROUGH | 08/14/2006 | APPROVED - AS NOTED | KSAMPICO |
| Note: THIS IS A REINSPECTION Missing fireblocking at soffit for dryer vent and fireplace. Need to secure receptacle at spa tub and kitchen hall wall. Frayed wire at previous receptacle. Outlet at bay window not grounded. | |||
| ALL ROUGH | 08/10/2006 | Disapproved -FEE REQUIRED | KSAMPICO |
| Note: No approved plans on site. Bond spa tub pump to copper water lines. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/23/2006 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION.HAVE LETTER FOR STRAPS AT ALL ROUGH. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/17/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION.STILL NEED LETTER FOR INCORRECT STRAPS. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/09/2006 | CANCELLED BY APPLICANT | CMINI |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/05/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Valley strap in master not nailed, trusses not straped in garage, loose bolts on 3-ply connection, jacks on west wall not sitting on bearing point, letter needed for incorrect straps on load bearing wall, misaligned straps, bolts on sheer wall in shower area not into solid concrete, not ready. | |||
| LINTEL | 04/10/2006 | APPROVED | ARAYMOND |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 04/06/2006 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 03/29/2006 | APPROVED | JMCGOWEN |
| FIRST ROUGH PLUMBING INSPECTION | 03/27/2006 | APPROVED | ARAYMOND |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 05/19/2006 | 05/23/2006 |
| Note: Released By: LWOODROME Revision: Engineer's letter straping @ garage bearing wall | |||
| BLD | COMPLETE | 01/17/2006 | 01/23/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| SW1 | HOLD | 12/30/2005 | 01/30/2006 |
| Note: Held By: LAPTEKAR Need 3 sealed topo surveys using 1988 datum . Need lot grading plan to show proposed elevations next to existing elevations of the topo survey...I checked the main file....the only surveys in the file are boundary surveys. | |||
| ZON | COMPLETE | 12/30/2005 | 01/17/2006 |
| Note: Released By: HHERKERT | |||
| SW1 | HOLD | 02/22/2006 | |
| Note: Held By: LAPTEKAR Received topo surveys...still need a lot grading plan with proposed elevations in the swale and along all existing elevations of the topo...also need the proposed FFE of the house. | |||
| SW1 | COMPLETE | 02/23/2006 | |
| Note: Released By: LAPTEKAR Received a lot grading plan 2/23 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤452.00 | 12/15/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 12/15/2006 |
| REINSPECTION FEE | ¤40.00 | 12/15/2006 |
| REINSPECTION FEE | ¤40.00 | 12/15/2006 |
| REINSPECTION FEE | ¤40.00 | 12/15/2006 |
| REINSPECTION FEE | ¤40.00 | 12/15/2006 |
| REINSPECTION FEE | ¤40.00 | 12/15/2006 |
| REINSPECTION FEE | ¤40.00 | 12/15/2006 |
| REVISION | ¤40.00 | 12/15/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 03/01/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/01/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 03/01/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 03/01/2006 |
| MECHANICAL FEE | ¤214.80 | 03/01/2006 |
| PERMIT FEE | ¤1,201.20 | 03/01/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 03/01/2006 |
| PLAN CHECK FEE | ¤123.20 | 03/01/2006 |
| PLUMBING FEE | ¤214.80 | 03/01/2006 |
| RADON FEE | ¤21.61 | 03/01/2006 |
| ADMIN FEE | ¤20.00 | 03/01/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 03/01/2006 |
| BUILDING CODE ADMIN FUND | ¤21.61 | 03/01/2006 |
| ELECTRIC FEE | ¤214.80 | 03/01/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤11,151.91 |