Permit #2006010229

Permit Details

Status: COED

Parcel Id: 07-11-31-7035-00470-0040
CONDITIONED SPACE: 1536 sqft
CONDITIONED SPACE: 1536 sqft
GARAGE: 338 sqft
GARAGE: 338 sqft
OPENED PORCH (WITH ROOF) : 89 sqft
OPENED PORCH (WITH ROOF) : 89 sqft
Total Square Footage: 3926 sqft
Block: 00470
Subdivision: -
Job Phone: (386)931-5642
Location Address: 17 BUNKER VIEW DR
Type: DU - DUPLEX
Issue Date: 02/07/2006
NOC: RECORDED
Applicant name: TONY J BAUMERT
Owner: ANTHONY DURANTE

Address

129 NOTTINGHAM DRIVE

WEST WARWICK, RI 02893

Lot: 0040
Contracted Stated Job Value: ¤190,000.00
Job Description: DUPLEX
Type: CN

Contractor

CONSTRUCTION DEVELOPMENT INC
Status Location Address State License Number Phone
CANCEL

PO BOX 351536

PORT ORANGE , FL 32128

CGC1504898 (Exp: 08/31/2018) 386-503-9018

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 09/26/2006 FINAL APPROVED ACOOPER
Note: Unable to gain entry. No approved plans on site. Unable to inspect.
FINAL COMPLETE BUILDING INSPECTION 09/22/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. CONDENSOR AT LEFTSIDE OF BLDG. WILL NOT PULL-OUIT OF DISCONNECT BOX 2. DRYWALL BOTH MECHANICAL EQUIPMENT CLOSETS AT INSIDE / BOTH GARAGES 3. PATCH HOLES INSIDE GARAGE WALLS 4. ARC RINGS AT DISPOSAL(S) AND MICROWAVE (S) 5. CONDENSATE LINE RIGHT UNIT AT EXTERIOR NOT COMPLETED 6. LFCN CABLES BOTH BUILDINGS ARE TRIP-HAZARDS AND NEED TO BE REPLACED WITH LONGER LFCN AND COVERED WITH A METAL PROTECTOR WHICH IS TO BE ATTACHED TO THE CONCRETE 7. LOW VOLTAGE / HOLES AT CONDENSOR UNITS TO BE PLUGGED
STORMWATER FINAL INSPECTION 09/08/2006 APPROVED DRANDALL
Note: THIS IS A REINSPECTION
UTILITY COMPANY FINAL 08/10/2006 APPROVED TSCHWEERS
STORMWATER FINAL INSPECTION 08/09/2006 Disapproved -FEE REQUIRED DRANDALL
Note: remove dumpster & port-o-let.....remove trash from adj. property rear.....135 sf road damage
PRE DRIVEWAY 07/13/2006 APPROVED - AS NOTED DRANDALL
Note: clean out 6" in under culvert ends
FIREWALL INSPECTION 2ND ROUGH 05/26/2006 APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
FIREWALL INSPECTION 2ND ROUGH 05/25/2006 Disapproved -FEE REQUIRED JLEVRAULT
Note: TWO X FOUR BLOCK RUNNING THROUGH FIREWALL - REMOVE.
INSULATION INSPECTION 05/18/2006 APPROVED - AS NOTED JLEVRAULT
Note: FIREWALL INSPECTION SHOULD HAVE BEEN DONE BEFORE INSULATION. MAKE SURE IT IS DONE.
INSULATION INSPECTION 05/17/2006 Disapproved -FEE REQUIRED ARITTER
Note: no plans on job
ALL ROUGH 05/09/2006 APPROVED JLEVRAULT
Note: THIS IS A REINSPECTION
ALL ROUGH 05/03/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. electrical code: 314.17 (c) 8" (both units) 2. need approved plans for arched windows/ shim windows 3. right unit stud at tub babk b. room 4. foam under all tubs 5. box top of electrical panel 6. exterior arches to be tapconned 12" o.c. at p.t.
FIREWALL FRAMING (DUPLEX) 04/13/2006 APPROVED JLEVRAULT
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/13/2006 APPROVED - AS NOTED JLEVRAULT
Note: FRAMING AROUND FOUR FRONT ARCHED WINDOWS NOT COMPLETED AND INSPECTED. CHECK AT ALL ROUGH.
PRE DRIVEWAY 03/31/2006 CANCELLED BY INSPECTOR WKINELL
Note: Swale sheet not completed.\\wk
LINTEL 03/29/2006 APPROVED JLEVRAULT
FOUNDATION SURVEY APPROVED BY STORMWATER 03/28/2006 APPROVED LAPTEKAR
MONOLITHIC SLAB INSPECTION/SLAB 03/03/2006 APPROVED JLEVRAULT
FIRST ROUGH PLUMBING INSPECTION 03/02/2006 APPROVED JLEVRAULT

Review History

Department Status Date In Date Out
SW1 COMPLETE 03/28/2006 03/28/2006
Note: Released By: LAPTEKAR Filled out ROW.3/28/06
BLD COMPLETE 02/03/2006 02/06/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet.
ZON COMPLETE 01/27/2006 01/27/2006
Note: Released By: ECOYNE
BLD HOLD 01/27/2006 02/01/2006
Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. 1. Wrapping of ductboard is not an acceptable solution unless a gwb chase independent of the ductboard is constructed. Either remove option from drawings or provide a detail showing how chase is to be constructed. 2. Provide UL Assembly Number for tenant separation wall. Indicate specific installation requirements on section that are required to meet UL Assembly criteria. 3. Provide UL Assembly Number(s) and applicable detail(s)/note(s) for any penetrations of tenant separation wall. *No penetrations of tenant separation wall will be allowed without this information.
ZON HOLD 01/11/2006 01/26/2006
Note: Held By: ECOYNE hold for ARC meeting 01/27/06

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 09/26/2006
REINSPECTION FEE ¤40.00 09/26/2006
REINSPECTION FEE ¤40.00 09/26/2006
REINSPECTION FEE ¤40.00 09/26/2006
REINSPECTION FEE ¤40.00 09/26/2006
STORMWATER REINSPECTION FEE ¤35.00 09/26/2006
TRANS IMPACT FEE 4 - PER UNIT ¤6,497.02 02/07/2006
SCHOOL BOARD IMPACT FEE RES ¤7,200.00 02/07/2006
STORM WATER PERMIT FEES ¤80.00 02/07/2006
ADMIN FEE ¤20.00 02/07/2006
ARC HOUSE REVIEW ¤125.00 02/07/2006
BUILDING CODE ADMIN FUND ¤19.63 02/07/2006
ELECTRIC FEE ¤207.60 02/07/2006
FIRE RES IMPACT FEE 4-1-05 ¤346.94 02/07/2006
MECHANICAL FEE ¤207.60 02/07/2006
PERMIT FEE ¤1,154.40 02/07/2006
PARKS IMPACT FEE 11-2-04 ¤2,241.82 02/07/2006
PLAN CHECK FEE ¤118.40 02/07/2006
PLUMBING FEE ¤207.60 02/07/2006
RADON FEE ¤19.63 02/07/2006
Fees Total Due: ¤0.00 Total Paid: ¤18,680.64