I want to search for...
Permit #2006010296
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7064-00040-0060 |
| CONDITIONED SPACE: 3088 sqft |
| GARAGE: 509 sqft |
| OPENED PORCH (WITH ROOF) : 65 sqft |
| OPENED PORCH (WITH ROOF) : 270 sqft |
| Total Square Footage: 3932 sqft |
| Block: 00040 |
| Subdivision: - |
| Job Phone: (386)931-4741 |
| Location Address: 11 LLOVERA PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/24/2006 |
| NOC: RECORDED |
| Applicant name: FOSTER H COLEMAN |
| Owner: LHP SCALES INC |
|
Address PO BOX 1207 FLAGLER BEACH, FL 32136 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤290,000.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
Fantastic Homes Const.Inc. (Foster Coleman)
| Status | Location Address | State License Number | Phone |
| CANCEL |
132 N PENINSULA DR DAYTONA BEACH, FL 32118 |
CGC003579 (Exp: 08/31/2016) | 386-307-1666 |
Sub Contractors
Masters Electric Inc. of S. Daytona (Electrical Contractor)
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1725 South Nova Road S. Daytona, FL 32119 |
EC000989 (Exp: 08/31/2006) | (386) 304-2600 | (386)304-9740 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
MARTIN JOHN EVANS
| Status | Location Address | State License Number |
| ACTIVE |
14 FORT CAROLINE CT BUNNELL, FL 32110 |
CFC057676 (Exp: 08/31/2026) |
FOSTER H COLEMAN
| Status | Location Address | State License Number | Phone |
| CANCEL |
132 N PENINSULA DR DAYTONA BEACH, FL 32118 |
CGC003579 (Exp: 08/31/2016) | 386-307-1666 |
Inspection History
| Type | Request Date | Result | Inspector |
| DRIVEWAY | 01/23/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: NEED 5 '' MIN , AT A 90 deg , CUT NOT A 45 deg. AND REMOVE ALL SOD FROM APRON BASE ONLY COMPACTED SUBGRADE OF CLEAN GRANULAR MATERIAL IS ALLOWED OR LIMEROCK OR SHELL BASE. | |||
| INSULATION INSPECTION | 08/01/2006 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 07/31/2006 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: insulate above front door, seal ac chases, seal chase at master bath, seal chase at stairway | |||
| INSULATION INSPECTION | 07/27/2006 | Disapproved -FEE REQUIRED | KSAMPICO |
| Note: MISSING INSULATION GARAGE WALL. FIRESTOP/FRAME AT LINES TO AHU BEHIND CLOSET NEAR GARAGE. FIRESTOP AT DUCTWORK CHASE UPSTAIRS. | |||
| ALL ROUGH | 07/25/2006 | APPROVED - AS NOTED | KSAMPICO |
| Note: *******check for hole to be patched at roof when vent pipe was relocated in upstairs bathroom.****** | |||
| ALL ROUGH | 07/21/2006 | Disapproved -FEE REQUIRED | KSAMPICO |
| Note: Framing incomplete. Strap electrical at panel. | |||
| LATH /BRICK FLASHING | 06/06/2006 | APPROVED | JMCGOWEN |
| Note: check for screet to be 6" above grade at final. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/12/2006 | APPROVED | DROCKWELL |
| EXTERIOR WALL SHEATHING/SHEAR WALL | 03/30/2006 | APPROVED | DROCKWELL |
| LINTEL | 03/15/2006 | APPROVED - AS NOTED | JGIBSON |
| Note: Inspection was done on 3/14/06. | |||
| LINTEL | 03/14/2006 | APPROVED | JGIBSON |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 03/13/2006 | APPROVED - AS NOTED | WKINELL |
| Note: Need survey that shows road CL elevation.\\wk | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 03/02/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 03/01/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Steel not overlaping by 25'' missing interior footing in garage. | |||
| FIRST ROUGH PLUMBING INSPECTION | 02/27/2006 | APPROVED | JGIBSON |
| DRIVEWAY | |||
| Note: THIS IS A REINSPECTION | |||
| STORMWATER FINAL INSPECTION | |||
| UTILITY COMPANY FINAL | |||
| FINAL COMPLETE BUILDING INSPECTION |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 09/07/2006 | 09/07/2006 |
| Note: Released By: WKINELL DW location changed. # new topo survey/ LGPs submitted and reviewed.\\wk | |||
| BLD | COMPLETE | 02/01/2006 | 02/02/2006 |
| Note: Released By: LWOODROME Revision: Post and columns | |||
| BLD | COMPLETE | 01/27/2006 | 01/31/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R. | |||
| ZON | COMPLETE | 01/27/2006 | 01/27/2006 |
| Note: Released By: MDEFREITAS Held By: ECOYNE Need landscaping plans faxed | |||
| ZON | COMPLETE | 01/27/2006 | 01/27/2006 |
| Note: Released By: ECOYNE | |||
| SW1 | COMPLETE | 01/12/2006 | 01/31/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | HOLD | 01/12/2006 | 01/26/2006 |
| Note: Held By: ECOYNE On hold for ARC meeting 0l/27/06 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN FEE | ¤20.00 | 02/24/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 02/24/2006 |
| BUILDING CODE ADMIN FUND | ¤19.66 | 02/24/2006 |
| ELECTRIC FEE | ¤205.80 | 02/24/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 02/24/2006 |
| MECHANICAL FEE | ¤205.80 | 02/24/2006 |
| PERMIT FEE | ¤1,142.70 | 02/24/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 02/24/2006 |
| PLAN CHECK FEE | ¤117.20 | 02/24/2006 |
| PLUMBING FEE | ¤205.80 | 02/24/2006 |
| RADON FEE | ¤19.66 | 02/24/2006 |
| REVISION | ¤40.00 | 02/24/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 02/24/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 02/24/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 02/24/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | |
| SW REVISION | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| Fees | Total Due: ¤235.00 | Total Paid: ¤10,324.51 |