I want to search for...
Permit #2006010308
Permit Details
Status: COED
| Parcel Id: 07-11-31-7027-00150-0130 |
| CONDITIONED SPACE: 2440 sqft |
| GARAGE: 681 sqft |
| OPENED PORCH (WITH ROOF) : 542 sqft |
| OPENED PORCH (WITH ROOF) : 71 sqft |
| Total Square Footage: 3734 sqft |
| Block: 0015 |
| Subdivision: - |
| Job Phone: (386) 445-4515 |
| Location Address: 48 WOODWORTH DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/24/2006 |
| NOC: RECORDED |
| Applicant name: GREGORY LEE LE PERA |
| Owner: RICHARD D. TUCKER |
|
Address 1411 DECATUR STREET, NW WASHINGTON, DC 20011 |
| Lot: 130 |
| Contracted Stated Job Value: ¤33,633.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
WAYNE HOMES BY CENTEX
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
385 DOUGLAS AVE ALTAMONTE SPRINGS, FL 32714 |
STE 3000 ALTAMONTE SPRINGS, FL 32714 |
CBC055301 (Exp: 09/30/2008) | (386) 445-4515 | (386)446-6285 |
Sub Contractors
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
GARY WAYNE EVERS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 740106 ORANGE CITY, FL 32763 |
CFC050566 (Exp: 08/31/2026) | 386-775-0909 | 386-775-0918 |
RICHARD H SIMMONS JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P. O. Box 1963 Bunnell, FL 32110 |
ER0011613 (Exp: 08/31/2008) | (386) 437-0607 | (386)437-1847 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 08/08/2006 | FINAL APPROVED | PGALLMANN |
| STORMWATER FINAL INSPECTION | 08/04/2006 | APPROVED - AS NOTED | DRANDALL |
| Note: remove trash rear adj. property.....36 sf road damage | |||
| UTILITY COMPANY FINAL | 07/25/2006 | APPROVED | TSCHWEERS |
| RESIDENTIAL EARLY POWER | 07/11/2006 | APPROVED | RMARVEL |
| DRIVEWAY | 07/06/2006 | APPROVED | BFCHAMBERLAIN |
| Note: THIS IS A REINSPECTION | |||
| DRIVEWAY | 07/05/2006 | Disapproved -FEE REQUIRED | BFCHAMBERLAIN |
| Note: Rebar missing. | |||
| LATH /BRICK FLASHING | 05/18/2006 | APPROVED | PGALLMANN |
| INSULATION INSPECTION | 05/17/2006 | APPROVED | PGALLMANN |
| ALL ROUGH | 05/15/2006 | APPROVED | PGALLMANN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/28/2006 | APPROVED | PGALLMANN |
| TEMPORARY POLE | 04/07/2006 | APPROVED | JLEVRAULT |
| Note: CALLED SUSAN AT 2:20 | |||
| LINTEL | 04/07/2006 | APPROVED | JLEVRAULT |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 04/04/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 03/28/2006 | APPROVED | ARITTER |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 03/24/2006 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: NOT READY. | |||
| FIRST ROUGH PLUMBING INSPECTION | 03/23/2006 | APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| FIRST ROUGH PLUMBING INSPECTION | 03/21/2006 | Disapproved -FEE REQUIRED | ARITTER |
| Note: no plans in box |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 02/20/2006 | 02/23/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | HOLD | 02/09/2006 | 02/10/2006 |
| Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. The roof loading indicated on the revised sheet 6 does not meet code requirements for general attic space of 10psf live load per FRC Table R301.5. The top chord loading meets the code requirements of Table R301.6 however the bottom chord does not meet the live load requirement of Table R301.5. Please revise the roof loading information on sheet 6. | |||
| BLD | HOLD | 01/31/2006 | 02/06/2006 |
| Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. The truss layout does not indicate whether there will be attic storage over the garage. In addition, the roof loading indicated does not meet code requirements for general attic space of 10psf live load and attic storage area(s), if used, of 20 psf live load per FRC Table R301.5. Revise roof loading information on sheet 6. If trusses are not to be designed for attic storage then the drawings shall clearly indicate that "NO ATTIC STORAGE IS ALLOWED". | |||
| ZON | COMPLETE | 01/30/2006 | 01/31/2006 |
| Note: Released By: HHERKERT | |||
| ZON | HOLD | 01/26/2006 | 01/26/2006 |
| Note: Held By: HHERKERT site plan setbacks and survey setbacks do not match, signed and sealed survey is incorrect | |||
| SW1 | COMPLETE | 01/13/2006 | 01/30/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | HOLD | 01/23/2006 | |
| Note: Held By: HHERKERT landscape plan is required |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤388.00 | 08/10/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 08/10/2006 |
| REINSPECTION FEE | ¤40.00 | 08/10/2006 |
| REINSPECTION FEE | ¤40.00 | 08/10/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 08/10/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 02/24/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 02/24/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 02/24/2006 |
| ADMIN FEE | ¤20.00 | 02/24/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 02/24/2006 |
| BUILDING CODE ADMIN FUND | ¤18.67 | 02/24/2006 |
| ELECTRIC FEE | ¤181.20 | 02/24/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 02/24/2006 |
| MECHANICAL FEE | ¤181.20 | 02/24/2006 |
| PERMIT FEE | ¤982.80 | 02/24/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 02/24/2006 |
| PLAN CHECK FEE | ¤100.80 | 02/24/2006 |
| PLUMBING FEE | ¤181.20 | 02/24/2006 |
| RADON FEE | ¤18.67 | 02/24/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,575.43 |