I want to search for...
Permit #2006010325
Permit Details
Status: COED
| Parcel Id: 07-11-31-7031-00580-0120 |
| CONDITIONED SPACE: 2050 sqft |
| GARAGE: 455 sqft |
| OPENED PORCH (WITH ROOF) : 185 sqft |
| OPENED PORCH (WITH ROOF) : 45 sqft |
| Total Square Footage: 2735 sqft |
| Block: 00580 |
| Subdivision: - |
| Job Phone: (386)447-8680 |
| Location Address: 18 RIVERDALE LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/01/2006 |
| NOC: RECORDED |
| Applicant name: MICHAEL LEO BRANIFF |
| Owner: FULTON WILLIAM B AND FULTON VIOLA |
|
Address 217-04 132ND ROAD SPRINGFIELD GARDENS, NY 11413 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤164,100.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
RIVER CITY HOMES
| Status | Location Address | State License Number | Phone |
| CANCEL |
12058 SAN JOSE BLVD #804 Jacksonville, FL 32223 |
CGC062728 (Exp: 08/31/2012) | 904-260-9009 |
Sub Contractors
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 1009 BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2014) | (386) 931-2568 | 386-313-3445 |
MICHAEL DAVID CLARK
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Box 918 Bunnell, FL 32110 |
CAC044867 (Exp: 09/30/2008) | (386) 437-2001 |
SCOTT RICHARD GATTIE
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1508 CLAPTON DR DELAND, FL 32720 |
CFC057990 (Exp: 08/31/2010) | (386)740-9227 | (386)740-9228 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 12/19/2006 | FINAL APPROVED | JHINDMAN |
| FINAL COMPLETE BUILDING INSPECTION | 12/15/2006 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: NEED ARC SHIELDS AT MIRROR RECEPTICLES, SEAL RANGE VENT ABOVE CABINET | |||
| STORMWATER FINAL INSPECTION | 12/13/2006 | APPROVED - AS NOTED | GLALIMA |
| Note: THIS IS A REINSPECTION 20 FEET ROAD DAMAGE =260.00 | |||
| STORMWATER FINAL INSPECTION | 12/06/2006 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: REGRADE SWALE ACROSS THE STREET , AND TO THE RIGHT THEN SOD , REMEMBER PUT THE SOD AT THE SAME ELEVATION AS THE SWALE NOT 2 '' HIGHER. SEED SEED AND SEED REAR AND SIDE . CLEAN ALL OF ROAD SO I CAN ASSESS DAMAGE . | |||
| UTILITY COMPANY FINAL | 11/29/2006 | APPROVED | MBACON |
| RESIDENTIAL EARLY POWER | 11/14/2006 | APPROVED | LHITES |
| DRIVEWAY | 10/11/2006 | APPROVED | GLALIMA |
| LATH /BRICK FLASHING | 09/27/2006 | APPROVED | JHINDMAN |
| INSULATION INSPECTION | 08/31/2006 | APPROVED | KSAMPICO |
| ALL ROUGH | 08/29/2006 | APPROVED | PGALLMANN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/18/2006 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/09/2006 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Missing 2x4 posts at truss EO1, rear wall does not have a double top plate as indicated on plan. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/02/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: MISSING PARALLAMS PER PLAN.MISSING 3,2X4 BUILT UP POST LEFT SIDE E-01 PER PLAN. TRUSS E-04 CALLS FOR (3)HTS30s EACH SIDE AND HTT16 AT EACH SIDE AT SILL PLATE NOT TOP PLATE. TIGHTEN LOOSE THREADED RODS. | |||
| LINTEL | 07/18/2006 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 07/17/2006 | CANCELLED BY APPLICANT | RMARVEL |
| Note: THIS IS A REINSPECTION called in cancelation per Libby | |||
| LINTEL | 07/14/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: TYPICAL WALL SECTION SHOWS BOND BEAM LINTEL NEEDS TO BE TOP COURSE TROUGHOUT HOUSE. 4" HALF HIGHS ATOP OF FRONT ENTRANCE. | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 07/13/2006 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 06/28/2006 | APPROVED | JHINDMAN |
| FIRST ROUGH PLUMBING INSPECTION | 06/26/2006 | APPROVED | JHINDMAN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/28/2006 | 02/02/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R. | |||
| SW1 | COMPLETE | 01/17/2006 | 02/01/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 01/17/2006 | 01/28/2006 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤260.00 | 12/20/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 12/20/2006 |
| REINSPECTION FEE | ¤40.00 | 12/20/2006 |
| REINSPECTION FEE | ¤40.00 | 12/20/2006 |
| REINSPECTION FEE | ¤40.00 | 12/20/2006 |
| REINSPECTION FEE | ¤40.00 | 12/20/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 12/20/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 03/01/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 03/01/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/01/2006 |
| ADMIN FEE | ¤20.00 | 03/01/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 03/01/2006 |
| BUILDING CODE ADMIN FUND | ¤13.68 | 03/01/2006 |
| ELECTRIC FEE | ¤150.00 | 03/01/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 03/01/2006 |
| MECHANICAL FEE | ¤150.00 | 03/01/2006 |
| PERMIT FEE | ¤780.00 | 03/01/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 03/01/2006 |
| PLAN CHECK FEE | ¤80.00 | 03/01/2006 |
| PLUMBING FEE | ¤150.00 | 03/01/2006 |
| RADON FEE | ¤13.68 | 03/01/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,200.25 |