Permit #2006010470

Permit Details

Status: COED

CONDITIONED SPACE: 29852 sqft
OPENED PORCH (WITH ROOF) : 6624 sqft
Total Square Footage: 36476 sqft
Subdivision: 2085 - Tidelands at the Village Phase II
Job Phone: (407)838-1486
Location Address: 85 RIVERVIEW BEND S
Type: BCR - BUILDING COMMERCIAL RESIDENTIAL -CONDO
Issue Date: 02/28/2006
NOC: RECORDED
Applicant name: JAMES NICHOLSON BOYCE IV
Owner: CENTEX DESTINATION PROPERTIES
Contracted Stated Job Value: ¤2,686,680.00
Job Description: BUILDING #15, 20 -PLEX CONDOMINIUM
Type: CN

Contractor

CENTEX DESTINATION PROPERTIES
Status Location Address Mailing Address State License Number Phone
CANCEL

1064 GREENWOOD BLVD

LAKE MARY, FL 32746

STE. 200

LAKE MARY, FL 32746

CGC1508651 (Exp: 08/31/2010) (407)838-1486

Sub Contractors

TRUMAN E GAILEY JR
Status Location Address State License Number Phone Fax
ACTIVE

231 Jean St.

DAYTONA BEACH, FL 32114

EC0000265 (Exp: 08/31/2026) (386) 255-1418 (386)255-3429
ROBERT G DELLO RUSSO
Status Location Address State License Number Phone Fax
DECEASED

531 CODISCO WAY

SANFORD, FL 32771

CAC032448 (Exp: 08/31/2022) (407)831-2665 (407)333-3853
GARY WAYNE EVERS
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 740106

ORANGE CITY, FL 32763

CFC050566 (Exp: 08/31/2026) 386-775-0909 386-775-0918
WAYNE STEED
Status Location Address State License Number Phone
CANCEL

318 N. PINE AVENUE

IVERNESS, FL 34450

CCC058299 (Exp: 08/31/2010) (352)637-2422

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 12/07/2006 FINAL APPROVED JLEVRAULT
UTILITY COMMERCIAL FINAL 12/05/2006 APPROVED KKING
UTILITY COMPANY FINAL 12/05/2006 APPROVED JSHEVLIN
LANDSCAPE FINAL 12/01/2006 APPROVED WBUTLER
ENGINEERING FINAL 11/30/2006 APPROVED DMAY
FIRE FINAL 11/21/2006 APPROVED JPATTEE
PLUMBING FINAL 11/16/2006 APPROVED JGIBSON
ELECTRICAL FINAL 11/16/2006 APPROVED LHITES
H.V.A.C. FINAL 11/14/2006 APPROVED JLEVRAULT
THRESHOLD/AFFIDAVIT 11/13/2006 APPROVED PPROVIDER
Note: Threshold Inspector's report from Law & Associates, Inc.
COMMERCIAL POWER INSPECTION 10/17/2006 APPROVED RMARVEL
Note: 4th floor.
COMMERCIAL POWER INSPECTION 10/12/2006 APPROVED RMARVEL
Note: 3rd floor
COMMERCIAL POWER INSPECTION 10/04/2006 APPROVED - AS NOTED RMARVEL
Note: 1st and 2nd floor.
COMMERCIAL POWER INSPECTION 09/22/2006 APPROVED RMARVEL
FRAMING 09/22/2006 APPROVED JLEVRAULT
Note: APPROVED ON 8/16/06
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/22/2006 Disapproved - NO FEE JLEVRAULT
Note: NEED LETTER OF MISSED INSPECTION.
MONOLITHIC SLAB INSPECTION/SLAB 09/22/2006 Disapproved - NO FEE JLEVRAULT
Note: NEED LETTER OF MISSED INSPECTION.
FOOTER 09/22/2006 Disapproved - NO FEE JLEVRAULT
Note: NEED LETTER OF MISSED INSPECTION.
LINTEL 09/22/2006 Disapproved - NO FEE JLEVRAULT
Note: NEED LETTER OF MISSED INSPECTION.
INSULATION INSPECTION 09/07/2006 APPROVED - AS NOTED JLEVRAULT
Note: Fourth floor insulation approved.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/31/2006 APPROVED PPROVIDER
Note: THIS IS A REINSPECTION Threshold inspectors report
ALL ROUGH 08/31/2006 APPROVED - AS NOTED RMARVEL
Note: 2nd rough electrical is ok. FOURTH FLOOR FRAMING AND MECHANICAL HAVE PASSED INSPECTION. (JRL)
INSULATION INSPECTION 08/21/2006 APPROVED - AS NOTED JLEVRAULT
Note: THIRD FLOOR INSULATION APPROVED.
FIREWALL INSPECTION 08/18/2006 APPROVED JPATTEE
FIREWALL INSPECTION 08/16/2006 CANCELLED BY INSPECTOR JPATTEE
ALL ROUGH 08/16/2006 APPROVED - AS NOTED JLEVRAULT
Note: ELECTRICAL, FRAMING AND MECHANICAL APPROVED. Porch detail to be turned in and approved.
INSULATION INSPECTION 08/16/2006 APPROVED - AS NOTED JLEVRAULT
Note: Building #15, 2nd floor OK
INSULATION INSPECTION 08/11/2006 APPROVED - AS NOTED JLEVRAULT
Note: For first floor only. Damaris
SECOND ROUGH PLUMBING INSPECTION 08/11/2006 APPROVED - AS NOTED JGIBSON
Note: Third & forth floor plumbing OK ONLY
FIREWALL INSPECTION 08/03/2006 APPROVED JPATTEE
Note: 1st 2nd floor penetrations
ALL ROUGH 07/26/2006 APPROVED - AS NOTED JGIBSON
Note: First & second floor plumbing tested OK. FIRST AND SECOND FLOOR FRAMING AND MECHANICAL PASSED INSPECTION (JL).
SECOND ROUGH PLUMBING INSPECTION 07/21/2006 APPROVED - AS NOTED JGIBSON
Note: First and second floor.
LINTEL 06/15/2006 APPROVED PPROVIDER
Note: 4 th floor lintel Threshold Inspectors report
SECOND FLOOR SLAB INSPECTION 06/01/2006 APPROVED PPROVIDER
Note: 4 th floor slab Threshold inspectors report
LINTEL 05/22/2006 APPROVED PPROVIDER
Note: 3 rd floor lintel Threshold Inspectors report
SECOND FLOOR SLAB INSPECTION 05/11/2006 APPROVED PPROVIDER
Note: 3 rd floor deck Threshold inspectors report
POURED CELL 05/01/2006 APPROVED PPROVIDER
Note: Threshold inspectors report
SECOND FLOOR SLAB INSPECTION 04/13/2006 APPROVED - AS NOTED PPROVIDER
Note: Threshold inspectors report
LINTEL 03/23/2006 APPROVED PPROVIDER
Note: THIS IS A REINSPECTION Threshold inspectors report
MONOLITHIC SLAB INSPECTION/SLAB 03/16/2006 APPROVED PPROVIDER
Note: THIS IS A REINSPECTION Threshold inspectors report
FIRST ROUGH PLUMBING INSPECTION 03/14/2006 APPROVED TOUTLAND
STEM FOOTING FOUNDATION 03/02/2006 APPROVED PPROVIDER
Note: Threshold inspectors report
FOOTER 02/24/2006 APPROVED PPROVIDER
Note: THIS IS A REINSPECTION Threshold inspectors report

Review History

Department Status Date In Date Out
BLD COMPLETE 02/21/2006 02/24/2006
Note: Released By: LWOODROME
FD1 COMPLETE 02/14/2006 02/14/2006
Note: Released By: JPATTEE
BLD HOLD 02/14/2006 02/15/2006
Note: Held By: FREODICA CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2006010470 (Tidelands - Building No. 15) 1. Revise Index of Drawings to match the drawing sheets title. Add drawing sheets P-8 and P-9 on the Index. 2. Provide product approval number for exterior doors . FYI: Complete product approval packets, for components and cladding, must be available, at the job site, at the time of inspection. 3. Provide details of guardrails, at balconies, that meet the requirements of FBC 1015. 4. Provide more information on details of balcony screen enclosure showing sizes, spacing and method of attachment. 5. Provide roofing application instructions per FBC 1507.4.1.2. 6. Identify condensing units (HP's) on drawing sheet E-3.
FD1 COMPLETE 01/20/2006 01/31/2006
Note: Released By: JPATTEE Held By: JPATTEE Sheet C-1 code data, NFPA 101 Life Safety Code 2001 edition is outdated , plans shall comply with NFPA 101, 2003 edition. NOTE: DO NOT JUST CHANGE CODE DATA TO COMPLY! Provide automatic fire sprinkler design criteria. Sheet A7.5.1 detail #4 indicates calculated fire resistance per 1994 SBC. Is this data outdated? Provide listing agency for 1 hour rated cmu tenant seperation wall. UL, FM etc.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN FEE ¤20.00 02/28/2006
BUILDING CODE ADMIN FUND ¤182.38 02/28/2006
ELECTRIC FEE ¤1,642.20 02/28/2006
FIRE COMM IMPACT FEE 4-1-05 ¤17,537.66 02/28/2006
FIRE PLANS REVIEW ¤364.76 02/28/2006
MECHANICAL FEE ¤1,642.20 02/28/2006
PERMIT FEE ¤14,778.50 02/28/2006
PARKS IMPACT FEE 11-2-04 ¤22,418.20 02/28/2006
PLUMBING FEE ¤1,642.20 02/28/2006
RADON FEE ¤182.38 02/28/2006
TTRANS IMPACT FEE CONDO/TOWN ¤29,120.00 02/28/2006
Fees Total Due: ¤0.00 Total Paid: ¤89,530.48