I want to search for...

Permit #2006010522

Permit Details

Status: COED

Parcel Id: 07-11-31-7063-00750-0100
CONDITIONED SPACE: 2178 sqft
GARAGE: 690 sqft
OPENED PORCH (WITH ROOF) : 256 sqft
OPENED PORCH (WITH ROOF) : 83 sqft
Total Square Footage: 3207 sqft
Block: 00750
Subdivision: -
Job Phone: (386) 445-7001
Location Address: 1 ZEALAND PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/02/2006
NOC: RECORDED
Applicant name: RICHARD M. ANDERSON
Owner: WELLS LARRY C & STEPHANIE ANN H&W

Address

5321 BOX TURTLE COURT

WOODBRIDGE, VA 22193

Lot: 0100
Contracted Stated Job Value: ¤181,000.00
Job Description: SINGLE FAMILY
Type: CN

Contractor

PALM WEST HOME BUILDERS, INC.
Status Location Address State License Number Phone Fax
ACTIVE

2 Florida Park Drive North

Palm Coast, FL 32137

CRC054633 (Exp: 08/31/2026) (386) 445-7001 (386)446-5941

Sub Contractors

JOHN S SMITH
Status Location Address State License Number
CANCEL

P. O. BOX 1160

Bunnell, FL 32110

ER0007785 (Exp: 08/31/2015)
MICHAEL G MORELLO JR
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32137

CAC014293 (Exp: 08/31/2014) (386)447-3950 (386)446-4614
THOMAS WALTER ALBANO
Status Location Address State License Number Phone Fax
INACTIVE

P. O. BOX 352075

Palm Coast, FL 32135

CFC045991 (Exp: 08/31/2024) 386-437-2795 (386)437-2781

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 04/02/2007 FINAL APPROVED JMCGOWEN
Note:
FINAL COMPLETE BUILDING INSPECTION 03/27/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: Richie caqlled in inspection, automative service was down NEED TO GROUT TOILETS......NEED TO HAVE ALL SWITCHES IN BEDROOMS ON ARC FAULT PROTECTION BREAKERS......NEED TO HAVE 4" MIN. CLEARANCE BETWEEN A/C PLENUM IN GARAGE......NEED TO REMOVE ACCESS COVER FOR INSPETION OF JACUZZI PUMP.....NEED TO HAVE NUMBER ON HOUSE.
STORMWATER FINAL INSPECTION 03/16/2007 APPROVED - AS NOTED DRANDALL
Note: 24 sf road.....$292
UTILITY COMPANY FINAL 03/16/2007 APPROVED MBACON
RESIDENTIAL EARLY POWER 03/06/2007 APPROVED LHITES
DRIVEWAY 01/26/2007 APPROVED GLALIMA
Note: THIS IS A REINSPECTION
DRIVEWAY 01/24/2007 CANCELLED BY APPLICANT GLALIMA
Note: Per Richard.....cancel this
INSULATION INSPECTION 09/20/2006 APPROVED KSAMPICO
ALL ROUGH 09/18/2006 APPROVED - AS NOTED KSAMPICO
Note: Bond spa pump to copper water supply. **** Check at insulation. ****
LATH /BRICK FLASHING 07/10/2006 APPROVED PGALLMANN
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 07/06/2006 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION. TRUSSES THAT NEEDED SHIMMING FOR AIRSPACE FROM PREVIOS INSPECTION WERE BEING ADDRESSED AT TIS INSPECTION,CHECK AT ALL ROUGH.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 06/12/2006 Disapproved -FEE REQUIRED CMINI
Note: AIR SPACE ON CMU WALL WHERE TRUSSES A7,A8,A9,B1-B6 ARE TO BE BEARING ON. NEED TO SHOW ON PLANS WHERE H2.5 AND H10s ARE TO BE USED FOR TRUSS TO STUD WALL CONNECTION. WASHER AND NUT MISSIBG ON BOLT 2X6 BEARING WALL LAUNDRY RM. BOLTS NEEDED ON CORNER SAME WALL. TRUSS D2 CONNECTION INCORRECTLY INSTALLED. NOT READY.
LINTEL 05/09/2006 APPROVED DROCKWELL
FOUNDATION SURVEY APPROVED BY STORMWATER 04/19/2006 APPROVED LAPTEKAR
TEMPORARY POLE 04/07/2006 APPROVED JGIBSON
Note: CALLED SUSAN AT 3:30
MONOLITHIC SLAB INSPECTION/SLAB 04/07/2006 APPROVED JGIBSON
FIRST ROUGH PLUMBING INSPECTION 04/05/2006 APPROVED JGIBSON

Review History

Department Status Date In Date Out
BLD COMPLETE 02/21/2006 02/23/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 02/13/2006 02/14/2006
Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. 1. The truss layout plan does not match the floor plan layout. Submit a revised roof truss layout. 2. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0.
URB HOLD 02/10/2006 02/13/2006
Note: Held By: CGOEWEY 2/13/06 (CB) YOU NEED TWO SHADE, TWO UNDERSTORY TREES. CHANGE OUT AN OAK FOR ANOTHER CRAPE MYRTLE.
ZON COMPLETE 02/08/2006 02/10/2006
Note: Released By: HHERKERT hold for ARC meeting 2-3-06
SW1 HOLD 01/23/2006 02/09/2006
Note: Held By: LAPTEKAR Need 3 sealed topo surveys and a lot grading plan to using 1988 NAVD.
ZON HOLD 01/23/2006 02/01/2006
Note: Held By: HHERKERT landscape required on the side of the house facing Zebulah's Trail
SW1 COMPLETE 02/16/2006
Note: Released By: LAPTEKAR found copies of topo in the main file 2/15
URB COMPLETE 02/14/2006
Note: Released By: CBENNETT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤292.00 04/03/2007
EARLY POWER INSPECTION ¤40.00 04/03/2007
REINSPECTION FEE ¤40.00 04/03/2007
REINSPECTION FEE ¤40.00 04/03/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 03/02/2006
STORM WATER PERMIT FEES ¤80.00 03/02/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 03/02/2006
ADMIN FEE ¤20.00 03/02/2006
ARC HOUSE REVIEW ¤125.00 03/02/2006
BUILDING CODE ADMIN FUND ¤16.04 03/02/2006
ELECTRIC FEE ¤165.00 03/02/2006
FIRE RES IMPACT FEE 4-1-05 ¤173.47 03/02/2006
MECHANICAL FEE ¤165.00 03/02/2006
PERMIT FEE ¤877.50 03/02/2006
PARKS IMPACT FEE 11-2-04 ¤1,120.91 03/02/2006
PLAN CHECK FEE ¤90.00 03/02/2006
PLUMBING FEE ¤165.00 03/02/2006
RADON FEE ¤16.04 03/02/2006
Fees Total Due: ¤0.00 Total Paid: ¤10,274.47