I want to search for...
Permit #2006010665
Permit Details
Status: COED
| Parcel Id: 07-11-31-7023-00150-0080 |
| CONDITIONED SPACE: 2064 sqft |
| GARAGE: 578 sqft |
| OPENED PORCH (WITH ROOF) : 358 sqft |
| OPENED PORCH (WITH ROOF) : 38 sqft |
| Total Square Footage: 3038 sqft |
| Block: 00150 |
| Subdivision: - |
| Job Phone: (386) 445-5239 |
| Location Address: 27 WHISPERING PINE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/19/2006 |
| NOC: RECORDED |
| Applicant name: MICHAEL W DILLARD |
| Owner: HORTON PETER & YELIZAVETA HORTON |
|
Address 657 B HAMILTON AVE WESTHAMPTON BEACH, NY 11978 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤169,900.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
DILLARD CONSTRUCTION LLC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 355007 PALM COAST, FL 32137 |
CGC1510399 (Exp: 09/30/2010) | 386-864-1320 | (386)986-3054 |
Sub Contractors
DANIEL R SHEFFIELD
| Status | Location Address | State License Number | Phone |
| INACTIVE |
1100 Old Haw Creek Road Bunnell, FL 32110 |
EC0003100 (Exp: 08/31/2024) | 386-931-4729 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
MARTIN JOHN EVANS
| Status | Location Address | State License Number |
| ACTIVE |
14 FORT CAROLINE CT BUNNELL, FL 32110 |
CFC057676 (Exp: 08/31/2026) |
MILLARD K KELLER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
313 S. VOLUSIA AVENUE DELAND, FL 32724 |
CCC1325778 (Exp: 08/31/2010) | (386) 774-9961 | (386)774-2388 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 01/17/2007 | FINAL APPROVED | PGALLMANN |
| Note: Contractor called to schedule a final inspection for 1/17/07 | |||
| STORMWATER FINAL INSPECTION | 01/12/2007 | APPROVED - AS NOTED | DRANDALL |
| Note: 24 sf road damage | |||
| UTILITY COMPANY FINAL | 01/11/2007 | APPROVED | MBACON |
| Note: THIS IS A REINSPECTION SCHEDULED A REINSPECTION AS PER JACKIE | |||
| UTILITY COMPANY FINAL | 01/04/2007 | Disapproved - NO FEE | TSCHWEERS |
| Note: FAILED, NO FINAL GRADEOR SOD DOWN YET JACKIE FROM DILLARD CALLED TO SCHEDULE A UTILITY FINAL FOR 1/4/07 | |||
| DRIVEWAY | 10/03/2006 | APPROVED | DRANDALL |
| LATH /BRICK FLASHING | 07/19/2006 | APPROVED | RMARVEL |
| INSULATION INSPECTION | 07/14/2006 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 07/13/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: need to fireblock at electrical panel.code section 717 fbc. | |||
| ALL ROUGH | 07/11/2006 | APPROVED | PGALLMANN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/17/2006 | APPROVED | PGALLMANN |
| LINTEL | 05/02/2006 | APPROVED | JLEVRAULT |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 05/01/2006 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 04/24/2006 | APPROVED | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 04/21/2006 | APPROVED | PGALLMANN |
| FIRST ROUGH PLUMBING INSPECTION | 04/20/2006 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: I NEED THIS INSPECTION TO BE DONE AFTERNOON ABOUT 12:00. THANK YOU. NOT READY |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 01/08/2007 | 01/12/2007 |
| Note: Released By: LAPTEKAR added 3' x 40' sidewalk on right side | |||
| SW1 | COMPLETE | 08/08/2006 | 08/09/2006 |
| Note: Released By: LAPTEKAR Received new topo/lot grading plan referencing 1988 NAVD Datum, however the benchmark item (a nail?) was not referenced...just the location of the benchmark was identified. Will process the swale sheet using the benchmark references from the topo survey. | |||
| SW1 | HOLD | 08/04/2006 | 08/04/2006 |
| Note: Held By: LAPTEKAR The original topo/lot grading plan submitted for this permit needs further clarification, in order to process the swale diagram. The datum required (1988 Datum) needs to be referenced and the item that is the benchmark, i.e. a nail, needs to be noted. Please submit 3 sealed topo surveys with the required information. Thank you. | |||
| BLD | COMPLETE | 03/24/2006 | 03/29/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R. | |||
| BLD | HOLD | 02/20/2006 | 03/20/2006 |
| Note: Held By: FREODICA Please resubmit energy calculations using NEW FORM, 600A-2004, Energy Gauge v. 4.0. as previously requested. | |||
| BLD | HOLD | 02/04/2006 | 02/09/2006 |
| Note: Held By: FREODICA The following items must be submitted in order to complete the Building Permit Application plan review. The current code version is the 2004 Florida Building Code - Residential (FRC 2004). 1. Indicate on drawings what type of door is to be used for door from garage to house. Reference FRC 2004 Section R309.1. 2. Indicate on the drawing the construction methods to be used to meet the required separation of garage from house and attic. Reference FRC Section R309.2. 3. Indicate whether attic access on garage will be pull-down stair or removable panel and indicate how access will be constructed to comply with FRC Section R309.2. 4. Update lintel schedule to match the safe gravity/uplift load values with those specified by manufacturer's catalog (cast- crete). 5. Provide detail as to how mechanical unit and ductwork will be constructed to comply FRC 2004, Section 309.1.1. 6. The Energy Packets submitted are outdated forms. Resubmit new 600A-2004 forms, Energy Gauge v.4.0. CITY OF PALM COAST o 2 COMMERCE BLVD o PALM COAST, FL 32164 PHONE: 386-986-3780 o FAX: 386-986-3781 *The City is also requesting that there is a 6" x 6" area on the cover page (first drawing sheet) for City comments and approval stamp. | |||
| SW1 | HOLD | 01/26/2006 | 02/16/2006 |
| Note: Held By: LAPTEKAR Need 3 sealed topo surveys using 1988 datum..and a lot grading plan showing proposed elevations next to the existing elevations. | |||
| ZON | COMPLETE | 01/26/2006 | 02/04/2006 |
| Note: Released By: HHERKERT | |||
| SW1 | COMPLETE | 03/22/2006 | |
| Note: Released By: LAPTEKAR received new topo surveys |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤292.00 | 01/19/2007 |
| REINSPECTION FEE | ¤40.00 | 01/19/2007 |
| REINSPECTION FEE | ¤40.00 | 01/19/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 04/19/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/19/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 04/19/2006 |
| ADMIN FEE | ¤20.00 | 04/19/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 04/19/2006 |
| BUILDING CODE ADMIN FUND | ¤15.19 | 04/19/2006 |
| ELECTRIC FEE | ¤156.60 | 04/19/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 04/19/2006 |
| MECHANICAL FEE | ¤156.60 | 04/19/2006 |
| PERMIT FEE | ¤822.90 | 04/19/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 04/19/2006 |
| PLAN CHECK FEE | ¤84.40 | 04/19/2006 |
| PLUMBING FEE | ¤156.60 | 04/19/2006 |
| RADON FEE | ¤15.19 | 04/19/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,147.37 |