I want to search for...

Permit #2006020033

Permit Details

Status: COED

Parcel Id: 16-11-30-0000-01010-0013
COMMERCIAL SQUARE FOOTAGE: 12000 sqft
Total Square Footage: 12000 sqft
Block: 101
Subdivision: 1150 - PALM COAST INDUSTRIAL PARK
Job Phone: (386)447-8680
Location Address: 15 HARGROVE LN
Type: BC - BUILDING COMMERCIAL
Issue Date: 05/09/2006
NOC: RECORDED
Applicant name: MICHAEL LEO BRANIFF
Owner: PALM COAST COMMERCIAL & INDUSTRIAL

Address

CENTER INC.

PALMCOAST, FL 32164

Lot: 13
Contracted Stated Job Value: ¤600,000.00
Job Description: LIGHT INDUSTRIAL WAREHOUSE BLG # 5
Type: CN

Contractor

RIVER CITY HOMES
Status Location Address State License Number Phone
CANCEL

12058 SAN JOSE BLVD #804

Jacksonville, FL 32223

CGC062728 (Exp: 08/31/2012) 904-260-9009

Sub Contractors

PETER JOSEPH LYDEN
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 1009

BUNNELL, FL 32110

EC0002436 (Exp: 08/31/2014) (386) 931-2568 386-313-3445
MICHAEL DAVID CLARK
Status Location Address State License Number Phone
CANCEL

P. O. Box 918

Bunnell, FL 32110

CAC044867 (Exp: 09/30/2008) (386) 437-2001
BRUCE EDWARD HAWKESWORTH
Status Location Address State License Number Phone
CANCEL

671 Dara Circle

DELTONA, FL 32735

CFC053329 (Exp: 09/30/2008) (386) 228-2784
BARRY D MARTIN
Status Location Address State License Number Phone Fax
CANCEL

1650 N STATE STREET

Bunnell, FL 32110

CCC033728 (Exp: 08/31/2020) (386) 437-7700 (386)437-7701

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 02/13/2007 FINAL APPROVED JLEVRAULT
UTILITY COMMERCIAL FINAL 02/08/2007 APPROVED KKING
LANDSCAPE FINAL 02/08/2007 APPROVED WBUTLER
FIRE FINAL 02/07/2007 APPROVED JPATTEE
ENGINEERING FINAL 02/07/2007 APPROVED DMAY
UTILITY COMPANY FINAL 01/19/2007 APPROVED TSCHWEERS
Note: Contractor called to schedule a utility final for 1/19/07
ELECTRICAL FINAL 11/21/2006 APPROVED LHITES
Note: ELECTRIC IS OK FPL NEEDS 11 METERS FOR BUILDING #5/ CALLED SUSAN AT FPL
FIREWALL INSPECTION 09/07/2006 APPROVED JPATTEE
FIREWALL INSPECTION 08/16/2006 CANCELLED BY INSPECTOR JPATTEE
Note: THIS IS A REINSPECTION
FIREWALL INSPECTION 08/15/2006 Disapproved -FEE REQUIRED JPATTEE
Note: THIS IS A REINSPECTION Not ready for inspection
FIREWALL INSPECTION 08/08/2006 Disapproved - NO FEE JPATTEE
Note: electrical conduit not sealed correctly some soffits had holes some were not finished no one onsite for inspection.
INSULATION INSPECTION 07/31/2006 APPROVED JLEVRAULT
ALL ROUGH 07/27/2006 APPROVED - AS NOTED JLEVRAULT
Note: LAG SINK SUPPORTS PROPERLY. DRAFTSTOP ALL PENETRATIONS WITH APPROVED MATERIALS.
ALL ROUGH 07/18/2006 APPROVED - AS NOTED JLEVRAULT
Note: FIREWALL FRAMING ONLY APPROVED.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 06/29/2006 APPROVED JLEVRAULT
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 06/28/2006 Disapproved -FEE REQUIRED JLEVRAULT
Note: THIS IS A REINSPECTION PLUMB TRUSSES.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 06/26/2006 Disapproved -FEE REQUIRED JLEVRAULT
Note: PLUMB TRUSSES AT CENTER LOAD BEARING WALL.
LINTEL 05/23/2006 APPROVED JLEVRAULT
LINTEL 05/18/2006 APPROVED JLEVRAULT
MONOLITHIC SLAB INSPECTION/SLAB 05/16/2006 APPROVED JLEVRAULT
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB INSPECTION/SLAB 05/15/2006 CANCELLED BY APPLICANT JLEVRAULT
FIRST ROUGH PLUMBING INSPECTION 05/11/2006 APPROVED JGIBSON

Review History

Department Status Date In Date Out
BLD COMPLETE 08/31/2006 09/01/2006
Note: Released By: CCOTE Approved for Release. REVISION: Updated energy forms to show 2 central a/c units.
BLD HOLD 08/11/2006 08/15/2006
Note: Held By: CCOTE Energy Forms submitted are the old 2001 code forms. Called Nicole on 8/15 and requested the new 2004 code forms be submitted.
BLD COMPLETE 05/17/2006 05/18/2006
Note: Released By: CCOTE Approved for Release. Revision: Revised truss layout to show design truss overhang.
BLD COMPLETE 05/11/2006 05/17/2006
Note: Released By: LWOODROME Revision: Slab and control joint
BLD COMPLETE 03/09/2006 03/17/2006
Note: Released By: LWOODROME
BLD HOLD 02/10/2006 03/03/2006
Note: Held By: LWOODROME PLAN REVIEW COMMENTS: " Provide a floor framing detail, for the storage area, above the office(s). " Provide a detail, which clarifies the method of attaching the overhangs (above the doorways) to the primary structure. " Specify roof sheathing material and provide a fasting schedule. " Specify door hardware, which complies with 2004 Florida Building Code, section 11-4.13.9, for H.C. accessibility. " Provide a door threshold detail, which indicates compliance with FBC, section 11-4.13.8, for H.C. accessibility. " Provide an attic access opening for each attic area. " Provide UL number and installation detail, for method of protecting penetrations of rated assemblies. " Provide a switched light inside each attic access. " Provide GFCI protection for receptacle outlets, in the restrooms. Larry Woodrome, CBO Chief Plans Examiner City of Palm Coast 386-986-3786
FI1 COMPLETE 02/01/2006 02/09/2006
Note: Released By: JPATTEE

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 02/13/2007
REINSPECTION FEE ¤40.00 02/13/2007
REINSPECTION FEE ¤40.00 02/13/2007
REVISION ¤40.00 02/13/2007
REVISION ¤40.00 02/13/2007
REVISION ¤40.00 02/13/2007
TRANSPORTATION IMPACT FEE ¤40,427.88 05/09/2006
ADMIN FEE ¤20.00 05/09/2006
BUILDING CODE ADMIN FUND ¤60.00 05/09/2006
ELECTRIC FEE ¤1,110.00 05/09/2006
FIRE COMM IMPACT FEE 4-1-05 ¤5,769.60 05/09/2006
FIRE PLANS REVIEW ¤120.00 05/09/2006
MECHANICAL FEE ¤1,110.00 05/09/2006
PERMIT FEE ¤9,900.00 05/09/2006
PLAN CHECK FEE ¤2,070.00 05/09/2006
PLUMBING FEE ¤1,110.00 05/09/2006
RADON FEE ¤60.00 05/09/2006
Fees Total Due: ¤0.00 Total Paid: ¤61,997.48