I want to search for...
Permit #2006020038
Permit Details
Status: COED
| Parcel Id: 07-11-31-7024-00400-0260 |
| CONDITIONED SPACE: 2452 sqft |
| GARAGE: 491 sqft |
| OPENED PORCH (WITH ROOF) : 61 sqft |
| SCREEN PORCH (SOLID ROOF) : 117 sqft |
| Total Square Footage: 3121 sqft |
| Block: 00400 |
| Subdivision: - |
| Job Phone: (386)445-9009 |
| Location Address: 18 PRESCOTT LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/06/2006 |
| NOC: RECORDED |
| Applicant name: BRIAN ANDREW GAZZOLI |
| Owner: SEAGATE HOMES |
|
Address 185 CYPRESS POINT PKWY PALM COAST, FL 32164 |
| Lot: 0260 |
| Contracted Stated Job Value: ¤204,272.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SEAGATE HOMES INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
185 CYPRESS POINT PARKWAY Palm Coast, FL 32137 |
SUITE 7 Palm Coast, FL 32137 |
CRC057202 (Exp: 08/31/2010) | 386-246-6125 | 386-246-6124 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
DENNIS GENE GAINEY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P.O. BOX 1203 Bunnell, FL 32110 |
CFC046004 (Exp: 08/31/2026) | (386) 437-5637 | 386-437-3012 |
MILLARD K KELLER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
313 S. VOLUSIA AVENUE DELAND, FL 32724 |
CCC1325778 (Exp: 08/31/2010) | (386) 774-9961 | (386)774-2388 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 03/19/2007 | FINAL APPROVED | JHINDMAN |
| Note: | |||
| FINAL COMPLETE BUILDING INSPECTION | 03/15/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: NEED TO HAVE ANOTHER SHADETREE....NEED ENERGY CALCS....NEED BUSHING IN DISCONNECT AT A/C CONDENSOR.. | |||
| STORMWATER FINAL INSPECTION | 03/12/2007 | APPROVED | DRANDALL |
| Note: 0 road damage | |||
| UTILITY COMPANY FINAL | 03/06/2007 | APPROVED | MBACON |
| Note: THIS IS A REINSPECTION | |||
| PRE DRIVEWAY | 02/22/2007 | CANCELLED BY INSPECTOR | LAPTEKAR |
| Note: already passed 2/21 | |||
| DRIVEWAY | 02/20/2007 | APPROVED | GLALIMA |
| RESIDENTIAL EARLY POWER | 02/20/2007 | APPROVED | RMARVEL |
| Note: called fpl at 11:30 | |||
| UTILITY COMPANY FINAL | 02/20/2007 | Disapproved - NO FEE | MBACON |
| Note: FAILED NO SOD NO DRIVEWAY OR SIDEWALKS | |||
| LATH /BRICK FLASHING | 01/23/2007 | APPROVED | ACOOPER |
| INSULATION INSPECTION | 01/11/2007 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 01/09/2007 | Disapproved -FEE REQUIRED | CMINI |
| Note: NEED TO REVISE ENERGY CALCS. TO MATCH EXISTING R-VALUES IN WALLS AND FLOORS. | |||
| ALL ROUGH | 12/28/2006 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 12/27/2006 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: truss ej5 not repaired per letter | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/22/2006 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION need to install plywood gusset per truss repair . | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/13/2006 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: OSB set on end at gables is to be reinforced at base, SHow fastening detail for META 18 at truss K1G. (This is a masonary connector on a wood bearing wall), Still need stamped revision for truss EJ5 at bearing point. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/06/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION. STILL NEED REVISION FOR JACK TRUSS EJ5.ALL REVISIONS MUST BE STAMPED BY BUILDING DEPT. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/06/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: STRAPS ON BONUS RM. GABLE NEED BLOCKING WHERE NAILS GO THOURGH PLYWOOD. NEED TO TAPCON STRAP RIGHT SIDE OF HOUSE OUTSIDE WALL. STRAP AT REAR PORCH FOR VALLEY NOT NAILED. NEED TO FILL EMPTY CELLS. JACK TRUSS EJ5 AT REAR PORCH NOT SITTING ON BEARING POINT. TRUSSES A-4 THROUGH A-6 NEED LETTER FROM ENGINEER,TRUSSES NOT SITTING ON SOLID BEARING POINTS. NOT READY. | |||
| LINTEL | 10/20/2006 | APPROVED | PGALLMANN |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 10/19/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 10/10/2006 | APPROVED | ACOOPER |
| FIRST ROUGH PLUMBING INSPECTION | 10/05/2006 | APPROVED | ACOOPER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/11/2007 | 01/12/2007 |
| Note: Released By: CCOTE Approved for Release. REVISION: Revised energy calcs. | |||
| BLD | COMPLETE | 12/19/2006 | 12/20/2006 |
| Note: Released By: CCOTE Approved for Release. REVISION: Truss Repair EJ5 | |||
| BLD | COMPLETE | 12/06/2006 | 12/07/2006 |
| Note: Released By: CCOTE Approved for Release. REVISION: Truss Repair A5. | |||
| BLD | COMPLETE | 07/05/2006 | 07/05/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Revision: Misc. plan changes. | |||
| ZON | COMPLETE | 06/30/2006 | 07/05/2006 |
| Note: Released By: ECOYNE | |||
| SW1 | COMPLETE | 03/08/2006 | 04/10/2006 |
| Note: Released By: WKINELL New topo surveys/lot grading pan submitted with no significant changes.\\wk | |||
| ZON | COMPLETE | 03/07/2006 | 03/07/2006 |
| Note: Released By: HHERKERT | |||
| BLD | COMPLETE | 03/07/2006 | 03/10/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| SW1 | HOLD | 02/01/2006 | 02/21/2006 |
| Note: Held By: LAPTEKAR The proposed elevations on the property line with the improved lot #27 fall in a negative direction. | |||
| ZON | HOLD | 02/01/2006 | 02/13/2006 |
| Note: Held By: JGONZALEZ MISSING SQ FT ON COVERED LANAI ON DRAWING. PLEASE SUBMIT CORRECTED SIGNED AND SEALED DRAWINGS. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 03/15/2007 |
| REINSPECTION FEE | ¤40.00 | 03/15/2007 |
| REINSPECTION FEE | ¤40.00 | 03/15/2007 |
| REINSPECTION FEE | ¤40.00 | 03/15/2007 |
| REINSPECTION FEE | ¤40.00 | 03/15/2007 |
| REINSPECTION FEE | ¤40.00 | 03/15/2007 |
| REINSPECTION FEE | ¤40.00 | 03/15/2007 |
| REVISION | ¤40.00 | 03/15/2007 |
| REVISION | ¤40.00 | 03/15/2007 |
| REVISION | ¤40.00 | 03/15/2007 |
| REVISION | ¤40.00 | 07/06/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 07/06/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 07/06/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 07/06/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 07/06/2006 |
| MECHANICAL FEE | ¤171.00 | 07/06/2006 |
| PERMIT FEE | ¤916.50 | 07/06/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 07/06/2006 |
| PLAN CHECK FEE | ¤94.00 | 07/06/2006 |
| PLUMBING FEE | ¤171.00 | 07/06/2006 |
| RADON FEE | ¤15.61 | 07/06/2006 |
| ADMIN FEE | ¤20.00 | 07/06/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 07/06/2006 |
| BUILDING CODE ADMIN FUND | ¤15.61 | 07/06/2006 |
| ELECTRIC FEE | ¤171.00 | 07/06/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,362.61 |