I want to search for...

Permit #2006020039

Permit Details

Status: COED

Parcel Id: 07-11-31-7029-00210-0130
CONDITIONED SPACE: 2154 sqft
GARAGE: 642 sqft
OPENED PORCH (WITH ROOF) : 162 sqft
OPENED PORCH (WITH ROOF) : 62 sqft
Total Square Footage: 3020 sqft
Block: 00210
Subdivision: -
Job Phone: (386)437-5782
Location Address: 1 RYLIN LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/13/2006
NOC: RECORDED
Applicant name: SANDRA LEE FRENCH
Owner: BROWN RALPH

Address

86 SMITH AVE

BAYSHORE, NY 11706

Lot: 0130
Contracted Stated Job Value: ¤160,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SANDEX HOMES
Status Location Address State License Number Phone Fax
CANCEL

27 EGAN DR

PALM COAST, FL

CRC1327302 (Exp: 09/30/2008) (386)437-5782 (386)437-5782

Sub Contractors

STEVEN JAY SMITH
Status Location Address State License Number Phone
INACTIVE

104 West Cedar Avenue

Orange City, FL 32763

EC0001542 (Exp: 08/31/2022) (386)775-7776
MICHAEL DAVID CLARK
Status Location Address State License Number Phone
CANCEL

P. O. Box 918

Bunnell, FL 32110

CAC044867 (Exp: 09/30/2008) (386) 437-2001
KEITH E PETRY
Status Location Address State License Number Phone Fax
CANCEL

11 RIPLE PLACE

PALM COAST, FL 32164

CCC1326298 (Exp: 08/31/2010) (386)586-3113 (000)000-0000
BRUCE EDWARD HAWKESWORTH
Status Location Address State License Number Phone
CANCEL

671 Dara Circle

DELTONA, FL 32735

CFC053329 (Exp: 09/30/2008) (386) 228-2784

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 03/23/2007 FINAL APPROVED ACOOPER
Note: CALLED BY SANDRA
STORMWATER FINAL INSPECTION 03/16/2007 APPROVED DRANDALL
Note: check road repair .... repaired by builder
STORMWATER FINAL INSPECTION 03/09/2007 Disapproved -FEE REQUIRED GLALIMA
Note: BUILD UP LEFT CENTER / REAR , GO OVER THIS WITH RICH. 28 sq ft road damage
STORMWATER FINAL INSPECTION 03/09/2007 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION READY FOR FINAL , 28' FEET =324.00 ROAD DAMAGE
UTILITY COMPANY FINAL 03/06/2007 APPROVED MBACON
PRE DRIVEWAY 02/14/2007 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION / FROM FEB , 13 , 2007 .
DRIVEWAY 02/12/2007 Disapproved -FEE REQUIRED GLALIMA
Note: NEED # 4 REBAR AND NO SMALLER , CLEAR OUT RIGHT SIDE OF DRIVEWAY 5'' MIN AND REMOVE 1' 1/4 TREEROOT.
INSULATION INSPECTION 10/04/2006 APPROVED CMINI
Note: THIS IS A REINSPECTION
INSULATION INSPECTION 09/27/2006 Disapproved -FEE REQUIRED RMARVEL
Note: outer block walls need a solid fire block. can not have insulation behind the top strip. missing fire stop in front bedroom.
ALL ROUGH 09/25/2006 APPROVED PGALLMANN
ALL ROUGH 09/14/2006 APPROVED - AS NOTED JMCGOWEN
Note: THIS IS A REINSPECTION.need revisions for witdh of hallway,and header over door going otside. have by insulation.
ALL ROUGH 09/01/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: NEED OUTLET IN FOYER- CHECK ALL WALL SPACING FOR OUTLETS- MISSING FIREBLOCKING NEED TO SEPARATE WHERE WIRES ARE BUNDLED CHECK NAIL PLATES THROUGHOUT HALLWAY NEEDS TO BE 3 FT AS TO APPROVED PLAN MISSING STRAPS ON WIRES 1 1/4 OFF FRAMING MEMBER UNUSED OPENING IN BOXES MUST BE SEALED ALUMINUM FOIL STRAPS NOT ALLOWED HEADER OVER DOOR GOING OUTSIDE MISSING JACK STUD OVER LOADED BOX FILL DINING ROOM. CHECK ALL BOXES WIRE STRAPPING NEEDS TO BE CODE STRAP WIRES WITHIN 12" ELECTRICAL PANEL. NEED TO BOND BOTH GROUNDING TERMINALS
LATH /BRICK FLASHING 08/25/2006 APPROVED CMINI
Note: THIS IS A REINSPECTION
LATH /BRICK FLASHING 08/10/2006 Disapproved -FEE REQUIRED CMINI
Note: NOT READY.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 07/05/2006 APPROVED CMINI
LINTEL 05/09/2006 APPROVED PGALLMANN
FOUNDATION SURVEY APPROVED BY STORMWATER 05/08/2006 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 04/19/2006 APPROVED CMINI
FIRST ROUGH PLUMBING INSPECTION 04/17/2006 APPROVED PGALLMANN

Review History

Department Status Date In Date Out
BLD COMPLETE 09/20/2006 09/21/2006
Note: Released By: CCOTE Approved for Release. REVISION: Door from lania straps. Hallway must be 3'-0" clear.
BLD COMPLETE 06/15/2006 06/15/2006
Note: Released By: LWOODROME Revision: Truss repair
BLD COMPLETE 03/22/2006 03/24/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R.
BLD HOLD 02/24/2006 03/01/2006
Note: Held By: FREODICA 1. Revise floor plan to show the type of lintel used for each window/dooor openings including entry, garage & lanai based on the revised submitted lintel schedule.
BLD HOLD 02/10/2006 02/13/2006
Note: Held By: FREODICA 1. Revise lintel schedule to match the safe load values with those of manufacture's "cast-crete" catalog. Specify the type/size of lintel to be used based on manufacturer's specifications (ex. 8F8-0B/1T, or 8F16-1B/1T etc.) 2. Indicate on truss schedule the specific type of truss connectors/fasteners to be used on each truss for this project.
ZON COMPLETE 02/10/2006 02/10/2006
Note: Released By: JGONZALEZ
SW1 HOLD 02/01/2006 02/20/2006
Note: Held By: LAPTEKAR Driveway flair is too close to the intersection.....the flair needs to be 60' from the intersection.
ZON HOLD 02/01/2006 02/07/2006
Note: Held By: HHERKERT hold for ARC meeting 2-10-06
SW1 COMPLETE 03/07/2006
Note: Released By: LAPTEKAR Received revised driveway site plan....driveway moved away from intersection

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 03/23/2007
REINSPECTION FEE ¤40.00 03/23/2007
REINSPECTION FEE ¤40.00 03/23/2007
REVISION ¤40.00 03/23/2007
REVISION ¤40.00 03/23/2007
STORMWATER REINSPECTION FEE ¤35.00 03/23/2007
STORMWATER REINSPECTION FEE ¤35.00 03/23/2007
STORMWATER REINSPECTION FEE ¤35.00 03/23/2007
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 04/13/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 04/13/2006
STORM WATER PERMIT FEES ¤80.00 04/13/2006
ADMIN FEE ¤20.00 04/13/2006
ARC HOUSE REVIEW ¤125.00 04/13/2006
BUILDING CODE ADMIN FUND ¤15.10 04/13/2006
ELECTRIC FEE ¤160.80 04/13/2006
FIRE RES IMPACT FEE 4-1-05 ¤173.47 04/13/2006
MECHANICAL FEE ¤160.80 04/13/2006
PERMIT FEE ¤850.20 04/13/2006
PARKS IMPACT FEE 11-2-04 ¤1,120.91 04/13/2006
PLAN CHECK FEE ¤87.20 04/13/2006
PLUMBING FEE ¤160.80 04/13/2006
RADON FEE ¤15.10 04/13/2006
Fees Total Due: ¤0.00 Total Paid: ¤10,122.89