I want to search for...
Permit #2006020039
Permit Details
Status: COED
| Parcel Id: 07-11-31-7029-00210-0130 |
| CONDITIONED SPACE: 2154 sqft |
| GARAGE: 642 sqft |
| OPENED PORCH (WITH ROOF) : 162 sqft |
| OPENED PORCH (WITH ROOF) : 62 sqft |
| Total Square Footage: 3020 sqft |
| Block: 00210 |
| Subdivision: - |
| Job Phone: (386)437-5782 |
| Location Address: 1 RYLIN LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/13/2006 |
| NOC: RECORDED |
| Applicant name: SANDRA LEE FRENCH |
| Owner: BROWN RALPH |
|
Address 86 SMITH AVE BAYSHORE, NY 11706 |
| Lot: 0130 |
| Contracted Stated Job Value: ¤160,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SANDEX HOMES
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
27 EGAN DR PALM COAST, FL |
CRC1327302 (Exp: 09/30/2008) | (386)437-5782 | (386)437-5782 |
Sub Contractors
STEVEN JAY SMITH
| Status | Location Address | State License Number | Phone |
| INACTIVE |
104 West Cedar Avenue Orange City, FL 32763 |
EC0001542 (Exp: 08/31/2022) | (386)775-7776 |
MICHAEL DAVID CLARK
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Box 918 Bunnell, FL 32110 |
CAC044867 (Exp: 09/30/2008) | (386) 437-2001 |
KEITH E PETRY
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
11 RIPLE PLACE PALM COAST, FL 32164 |
CCC1326298 (Exp: 08/31/2010) | (386)586-3113 | (000)000-0000 |
BRUCE EDWARD HAWKESWORTH
| Status | Location Address | State License Number | Phone |
| CANCEL |
671 Dara Circle DELTONA, FL 32735 |
CFC053329 (Exp: 09/30/2008) | (386) 228-2784 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 03/23/2007 | FINAL APPROVED | ACOOPER |
| Note: CALLED BY SANDRA | |||
| STORMWATER FINAL INSPECTION | 03/16/2007 | APPROVED | DRANDALL |
| Note: check road repair .... repaired by builder | |||
| STORMWATER FINAL INSPECTION | 03/09/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: BUILD UP LEFT CENTER / REAR , GO OVER THIS WITH RICH. 28 sq ft road damage | |||
| STORMWATER FINAL INSPECTION | 03/09/2007 | APPROVED - AS NOTED | GLALIMA |
| Note: THIS IS A REINSPECTION READY FOR FINAL , 28' FEET =324.00 ROAD DAMAGE | |||
| UTILITY COMPANY FINAL | 03/06/2007 | APPROVED | MBACON |
| PRE DRIVEWAY | 02/14/2007 | APPROVED - AS NOTED | GLALIMA |
| Note: THIS IS A REINSPECTION / FROM FEB , 13 , 2007 . | |||
| DRIVEWAY | 02/12/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: NEED # 4 REBAR AND NO SMALLER , CLEAR OUT RIGHT SIDE OF DRIVEWAY 5'' MIN AND REMOVE 1' 1/4 TREEROOT. | |||
| INSULATION INSPECTION | 10/04/2006 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 09/27/2006 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: outer block walls need a solid fire block. can not have insulation behind the top strip. missing fire stop in front bedroom. | |||
| ALL ROUGH | 09/25/2006 | APPROVED | PGALLMANN |
| ALL ROUGH | 09/14/2006 | APPROVED - AS NOTED | JMCGOWEN |
| Note: THIS IS A REINSPECTION.need revisions for witdh of hallway,and header over door going otside. have by insulation. | |||
| ALL ROUGH | 09/01/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: NEED OUTLET IN FOYER- CHECK ALL WALL SPACING FOR OUTLETS- MISSING FIREBLOCKING NEED TO SEPARATE WHERE WIRES ARE BUNDLED CHECK NAIL PLATES THROUGHOUT HALLWAY NEEDS TO BE 3 FT AS TO APPROVED PLAN MISSING STRAPS ON WIRES 1 1/4 OFF FRAMING MEMBER UNUSED OPENING IN BOXES MUST BE SEALED ALUMINUM FOIL STRAPS NOT ALLOWED HEADER OVER DOOR GOING OUTSIDE MISSING JACK STUD OVER LOADED BOX FILL DINING ROOM. CHECK ALL BOXES WIRE STRAPPING NEEDS TO BE CODE STRAP WIRES WITHIN 12" ELECTRICAL PANEL. NEED TO BOND BOTH GROUNDING TERMINALS | |||
| LATH /BRICK FLASHING | 08/25/2006 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 08/10/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: NOT READY. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/05/2006 | APPROVED | CMINI |
| LINTEL | 05/09/2006 | APPROVED | PGALLMANN |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 05/08/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 04/19/2006 | APPROVED | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 04/17/2006 | APPROVED | PGALLMANN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 09/20/2006 | 09/21/2006 |
| Note: Released By: CCOTE Approved for Release. REVISION: Door from lania straps. Hallway must be 3'-0" clear. | |||
| BLD | COMPLETE | 06/15/2006 | 06/15/2006 |
| Note: Released By: LWOODROME Revision: Truss repair | |||
| BLD | COMPLETE | 03/22/2006 | 03/24/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R. | |||
| BLD | HOLD | 02/24/2006 | 03/01/2006 |
| Note: Held By: FREODICA 1. Revise floor plan to show the type of lintel used for each window/dooor openings including entry, garage & lanai based on the revised submitted lintel schedule. | |||
| BLD | HOLD | 02/10/2006 | 02/13/2006 |
| Note: Held By: FREODICA 1. Revise lintel schedule to match the safe load values with those of manufacture's "cast-crete" catalog. Specify the type/size of lintel to be used based on manufacturer's specifications (ex. 8F8-0B/1T, or 8F16-1B/1T etc.) 2. Indicate on truss schedule the specific type of truss connectors/fasteners to be used on each truss for this project. | |||
| ZON | COMPLETE | 02/10/2006 | 02/10/2006 |
| Note: Released By: JGONZALEZ | |||
| SW1 | HOLD | 02/01/2006 | 02/20/2006 |
| Note: Held By: LAPTEKAR Driveway flair is too close to the intersection.....the flair needs to be 60' from the intersection. | |||
| ZON | HOLD | 02/01/2006 | 02/07/2006 |
| Note: Held By: HHERKERT hold for ARC meeting 2-10-06 | |||
| SW1 | COMPLETE | 03/07/2006 | |
| Note: Released By: LAPTEKAR Received revised driveway site plan....driveway moved away from intersection |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 03/23/2007 |
| REINSPECTION FEE | ¤40.00 | 03/23/2007 |
| REINSPECTION FEE | ¤40.00 | 03/23/2007 |
| REVISION | ¤40.00 | 03/23/2007 |
| REVISION | ¤40.00 | 03/23/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 03/23/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 03/23/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 03/23/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 04/13/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 04/13/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/13/2006 |
| ADMIN FEE | ¤20.00 | 04/13/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 04/13/2006 |
| BUILDING CODE ADMIN FUND | ¤15.10 | 04/13/2006 |
| ELECTRIC FEE | ¤160.80 | 04/13/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 04/13/2006 |
| MECHANICAL FEE | ¤160.80 | 04/13/2006 |
| PERMIT FEE | ¤850.20 | 04/13/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 04/13/2006 |
| PLAN CHECK FEE | ¤87.20 | 04/13/2006 |
| PLUMBING FEE | ¤160.80 | 04/13/2006 |
| RADON FEE | ¤15.10 | 04/13/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,122.89 |