I want to search for...
Permit #2006020069
Permit Details
Status: COED
| Parcel Id: 07-11-31-7065-00020-0080 |
| CONDITIONED SPACE: 1721 sqft |
| GARAGE: 415 sqft |
| OPENED PORCH (WITH ROOF) : 150 sqft |
| OPENED PORCH (WITH ROOF) : 18 sqft |
| Total Square Footage: 2304 sqft |
| Block: 00020 |
| Subdivision: - |
| Job Phone: (386) 445-4515 |
| Location Address: 1 KANTOR CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/27/2006 |
| NOC: RECORDED |
| Applicant name: GREGORY LEE LE PERA |
| Owner: PALMER LETFORD |
|
Address 392 AMBY ST BROOKLYN, NY 11212 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤70,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
WAYNE HOMES BY CENTEX
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
385 DOUGLAS AVE ALTAMONTE SPRINGS, FL 32714 |
STE 3000 ALTAMONTE SPRINGS, FL 32714 |
CBC055301 (Exp: 09/30/2008) | (386) 445-4515 | (386)446-6285 |
Sub Contractors
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
GARY WAYNE EVERS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 740106 ORANGE CITY, FL 32763 |
CFC050566 (Exp: 08/31/2026) | 386-775-0909 | 386-775-0918 |
GREGORY A HAGEMAN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
545 Parque Drive Ormond Beach, FL 32174 |
CCC021394 (Exp: 08/31/2026) | (386) 672-2821 |
RICHARD H SIMMONS JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P. O. Box 1963 Bunnell, FL 32110 |
ER0011613 (Exp: 08/31/2008) | (386) 437-0607 | (386)437-1847 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 08/03/2006 | FINAL APPROVED | DROCKWELL |
| UTILITY COMPANY FINAL | 08/01/2006 | APPROVED | MBACON |
| INSULATION INSPECTION | 07/31/2006 | APPROVED | LWOODROME |
| Note: THIS IS A REINSPECTION Engineer's letter recieved verify compliance with the approved plan and code. | |||
| STORMWATER FINAL INSPECTION | 07/13/2006 | APPROVED - AS NOTED | GLALIMA |
| Note: THIS IS A REINSPECTION 24 sq ft road damage $292 | |||
| STORMWATER FINAL INSPECTION | 07/10/2006 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: Place sod in adjacent swale 24 sq.ft. road damage remove trash | |||
| RESIDENTIAL EARLY POWER | 06/22/2006 | APPROVED | RMARVEL |
| DRIVEWAY | 06/09/2006 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| DRIVEWAY | 06/07/2006 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: PIPE NEEDS TO BE COVERED 50 % CUT 6 '' AT ROAD FLUSH / NOT AT 45. | |||
| LATH /BRICK FLASHING | 05/05/2006 | APPROVED | DROCKWELL |
| INSULATION INSPECTION | 05/02/2006 | CANCELLED BY APPLICANT | JGIBSON |
| ALL ROUGH | 04/27/2006 | APPROVED - AS NOTED | DROCKWELL |
| Note: Water before insulation | |||
| ALL ROUGH | 04/26/2006 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: electrical tape is not an approved strap, box fill at garage entry | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/11/2006 | APPROVED | JHINDMAN |
| LINTEL | 04/04/2006 | APPROVED | DROCKWELL |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 03/28/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 03/17/2006 | APPROVED | JHINDMAN |
| TEMPORARY POLE | 03/15/2006 | APPROVED | DROCKWELL |
| Note: called fpl on 3/15/06 at 3:45pm Damaris | |||
| FIRST ROUGH PLUMBING INSPECTION | 03/15/2006 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 07/27/2006 | 07/31/2006 |
| Note: Released By: LWOODROME Engineer's letter for missed inspection. Misc. fee $40.00 charged. | |||
| BLD | COMPLETE | 02/20/2006 | 02/23/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | HOLD | 02/13/2006 | 02/14/2006 |
| Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. The roof loading indicated on the revised sheet 8 does not meet code requirements for general attic space of 10psf live load per FRC Table R301.5. The top chord loading meets the code requirements of Table R301.6 however the bottom chord does not meet the live load requirement of Table R301.5. Please revise the roof loading information on sheet 6 to indicate 10psf bottom chord live load or provide a footnote to the loading table stating that a non-concurrent application of 10lbs bottom chord live load shall be applied to the entire chord. | |||
| SW1 | COMPLETE | 02/02/2006 | 02/24/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 02/02/2006 | 02/13/2006 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤292.00 | 08/01/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 08/01/2006 |
| MISCELLANEOUS | ¤40.00 | 08/01/2006 |
| REINSPECTION FEE | ¤40.00 | 08/01/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 08/01/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 08/01/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 02/27/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 02/27/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 02/27/2006 |
| PERMIT FEE | ¤659.10 | 02/27/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 02/27/2006 |
| PLAN CHECK FEE | ¤67.60 | 02/27/2006 |
| PLUMBING FEE | ¤131.40 | 02/27/2006 |
| RADON FEE | ¤11.52 | 02/27/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 02/27/2006 |
| MECHANICAL FEE | ¤131.40 | 02/27/2006 |
| ADMIN FEE | ¤20.00 | 02/27/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 02/27/2006 |
| BUILDING CODE ADMIN FUND | ¤11.52 | 02/27/2006 |
| ELECTRIC FEE | ¤131.40 | 02/27/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,993.83 |