Location Address: 1 KANTOR CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/27/2006
NOC: RECORDED
Applicant name: GREGORY LEE LE PERA
Owner: PALMER LETFORD

Address

392 AMBY ST

BROOKLYN, NY 11212

Lot: 0080
Contracted Stated Job Value: ¤70,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

WAYNE HOMES BY CENTEX
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

385 DOUGLAS AVE

ALTAMONTE SPRINGS, FL 32714

STE 3000

ALTAMONTE SPRINGS, FL 32714

CBC055301 (Exp: 09/30/2008) (386) 445-4515 (386)446-6285

Sub Contractors

MICHAEL G MORELLO JR
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32137

CAC014293 (Exp: 08/31/2014) (386)447-3950 (386)446-4614
GARY WAYNE EVERS
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 740106

ORANGE CITY, FL 32763

CFC050566 (Exp: 08/31/2026) 386-775-0909 386-775-0918
GREGORY A HAGEMAN
Status Location Address State License Number Phone
ACTIVE

545 Parque Drive

Ormond Beach, FL 32174

CCC021394 (Exp: 08/31/2026) (386) 672-2821
RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 1963

Bunnell, FL 32110

ER0011613 (Exp: 08/31/2008) (386) 437-0607 (386)437-1847

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 08/03/2006 FINAL APPROVED DROCKWELL
UTILITY COMPANY FINAL 08/01/2006 APPROVED MBACON
INSULATION INSPECTION 07/31/2006 APPROVED LWOODROME
Note: THIS IS A REINSPECTION Engineer's letter recieved verify compliance with the approved plan and code.
STORMWATER FINAL INSPECTION 07/13/2006 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION 24 sq ft road damage $292
STORMWATER FINAL INSPECTION 07/10/2006 Disapproved -FEE REQUIRED GLALIMA
Note: Place sod in adjacent swale 24 sq.ft. road damage remove trash
RESIDENTIAL EARLY POWER 06/22/2006 APPROVED RMARVEL
DRIVEWAY 06/09/2006 APPROVED GLALIMA
Note: THIS IS A REINSPECTION
DRIVEWAY 06/07/2006 Disapproved -FEE REQUIRED GLALIMA
Note: PIPE NEEDS TO BE COVERED 50 % CUT 6 '' AT ROAD FLUSH / NOT AT 45.
LATH /BRICK FLASHING 05/05/2006 APPROVED DROCKWELL
INSULATION INSPECTION 05/02/2006 CANCELLED BY APPLICANT JGIBSON
ALL ROUGH 04/27/2006 APPROVED - AS NOTED DROCKWELL
Note: Water before insulation
ALL ROUGH 04/26/2006 Disapproved -FEE REQUIRED JHINDMAN
Note: electrical tape is not an approved strap, box fill at garage entry
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/11/2006 APPROVED JHINDMAN
LINTEL 04/04/2006 APPROVED DROCKWELL
FOUNDATION SURVEY APPROVED BY STORMWATER 03/28/2006 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 03/17/2006 APPROVED JHINDMAN
TEMPORARY POLE 03/15/2006 APPROVED DROCKWELL
Note: called fpl on 3/15/06 at 3:45pm Damaris
FIRST ROUGH PLUMBING INSPECTION 03/15/2006 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
BLD COMPLETE 07/27/2006 07/31/2006
Note: Released By: LWOODROME Engineer's letter for missed inspection. Misc. fee $40.00 charged.
BLD COMPLETE 02/20/2006 02/23/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 02/13/2006 02/14/2006
Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. The roof loading indicated on the revised sheet 8 does not meet code requirements for general attic space of 10psf live load per FRC Table R301.5. The top chord loading meets the code requirements of Table R301.6 however the bottom chord does not meet the live load requirement of Table R301.5. Please revise the roof loading information on sheet 6 to indicate 10psf bottom chord live load or provide a footnote to the loading table stating that a non-concurrent application of 10lbs bottom chord live load shall be applied to the entire chord.
SW1 COMPLETE 02/02/2006 02/24/2006
Note: Released By: LAPTEKAR
ZON COMPLETE 02/02/2006 02/13/2006
Note: Released By: HHERKERT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤292.00 08/01/2006
EARLY POWER INSPECTION ¤40.00 08/01/2006
MISCELLANEOUS ¤40.00 08/01/2006
REINSPECTION FEE ¤40.00 08/01/2006
STORMWATER REINSPECTION FEE ¤35.00 08/01/2006
STORMWATER REINSPECTION FEE ¤35.00 08/01/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 02/27/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 02/27/2006
STORM WATER PERMIT FEES ¤80.00 02/27/2006
PERMIT FEE ¤659.10 02/27/2006
PARKS IMPACT FEE 11-2-04 ¤1,120.91 02/27/2006
PLAN CHECK FEE ¤67.60 02/27/2006
PLUMBING FEE ¤131.40 02/27/2006
RADON FEE ¤11.52 02/27/2006
FIRE RES IMPACT FEE 4-1-05 ¤173.47 02/27/2006
MECHANICAL FEE ¤131.40 02/27/2006
ADMIN FEE ¤20.00 02/27/2006
ARC HOUSE REVIEW ¤125.00 02/27/2006
BUILDING CODE ADMIN FUND ¤11.52 02/27/2006
ELECTRIC FEE ¤131.40 02/27/2006
Fees Total Due: ¤0.00 Total Paid: ¤9,993.83