I want to search for...

Permit #2006020130

Permit Details

Status: CANCEL

CONDITIONED SPACE: 22586 sqft
CONDITIONED SPACE: 20115 sqft
CONDITIONED SPACE: 20115 sqft
CONDITIONED SPACE: 20115 sqft
CONDITIONED SPACE: 18129 sqft
CONDITIONED SPACE: 18129 sqft
CONDITIONED SPACE: 18129 sqft
CONDITIONED SPACE: 16141 sqft
Total Square Footage: 153459 sqft
Block: 103
Subdivision: -
Job Phone: (407)838-1486
Location Address: 194 PALM COAST RESORT BLVD
Type: BCR - BUILDING COMMERCIAL RESIDENTIAL -CONDO
Issue Date: 03/28/2006
NOC: RECORDED
Applicant name: RALPH STEPHEN SMITH
Owner: CENTEX HOMES D/B/A DESTINATION PROPERTIES

Address

1064 GREENWOOD BLVD.

LAKE MARY, FL 32746

Address

SUITE 200

LAKE MARY, FL 32746

Lot: 0000
Contracted Stated Job Value: ¤23,312,472.00
Job Description: BUILDING D, 62 UNIT CONDO
Type: CN

Contractor

CENTEX DESTINATION PROPERTIES
Status Location Address Mailing Address State License Number Phone
CANCEL

1064 GREENWOOD BLVD

LAKE MARY, FL 33746

SUITE 200

LAKE MARY, FL 32746

CGC1506882 (Exp: 09/30/2008) (407)838-1486

Sub Contractors

RONALD A AUTREY
Status Location Address State License Number Phone
CANCEL

PO Box 1799

Jacksonville, Fl., 32201

ECOOOO388 (Exp: 08/31/2018) (904) 388-8000
ROBERT G DELLO RUSSO
Status Location Address State License Number Phone Fax
DECEASED

531 CODISCO WAY

SANFORD, FL 32771

CAC032448 (Exp: 08/31/2022) (407)831-2665 (407)333-3853
ISAAC WALTER JOHNSTON
Status Location Address State License Number Phone
ACTIVE

887 BRENTWOOD DRIVE

Daytona Beach, FL 32117

CFC023634 (Exp: 08/31/2026) (386) 252-7047
BRADFORD DAVIS BELDON
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 13380

SAN ANTONIO, TX 78213

CCC057757 (Exp: 08/31/2010) (210)341-3100 (210)341-2959

Inspection History

Type Request Date Result Inspector
FIRST ROUGH PLUMBING INSPECTION
SECOND ROUGH PLUMBING INSPECTION
MONOLITHIC SLAB INSPECTION/SLAB
FOOTER
SECOND FLOOR SLAB INSPECTION
COLUMN INSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL
COLUMN,POST,BEAM,TIE DOWN CONNECTER INSPECTION
UNDERGROUND ELECTRICAL
2ND ROUGH ELECTRICAL
INSULATION INSPECTION
INSULATION INSPECTION
FIREWALL INSPECTION
FIREWALL INSPECTION
FIREWALL INSPECTION 2ND ROUGH
FIREWALL INSPECTION 3ND ROUGH
FIREWALL FINAL INSPECTION
ENGINEERING FINAL
UTILITY COMMERCIAL FINAL
UTILITY COMPANY FINAL
LANDSCAPE FINAL
FIRE FINAL
FINAL COMPLETE BUILDING INSPECTION

Review History

Department Status Date In Date Out
BLD COMPLETE 03/10/2006 03/14/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 02/14/2006 02/16/2006
Note: Held By: CCOTE CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2006020130 (194 Palm Coast Resort Blvd. - Bldg. D) 1. The following items regarding the size of underground piping needs to be clarified: a. All of the riser diagrams show plumbing fixtures for the 1st floor level when this level is actually a parking structure. Revise risers to show actual conditions by removing fixtures and showing additional offsets, cleanouts and pipe size changes. b. Several sanitary risers show a 4" line reducing down to a 3" line which is not allowed. Revise as required. c. Several sanitary risers show a 4" line while the plumbing plan shows the line 3". Revise as required. d. Riser S27 identified on the plan cannot be found. 2. Details 5/A7.3 & 15/A7.3 for the guard rails do not indicate how rails and posts are secured to the structure and how balusters are connected to rails to meet the load requirements of FBC 1607.7. 3. The following sheet names on the drawing index did not match those found on the drawing title block: a. E-1.8 b. E-1.9 c. E-1.10 d. E-1.11 e. E-1.12 f. E-1.13 g. E-1.14 h. E-1.15 i. E-1.16 j. P-1.5 k. P-1.6 l. P-1.7 m. S-1.1 4. The following sheets were found in the drawing package but were not listed on the drawing index list: a. E1.17 b. E1.18 c. P1.15 d. P1.16 5. It appears that some of the developed lengths of clothes dryer ducts exceed 25 feet. Either a booster fan is required or a clothes dryer stating with manufacturer information stating a developed length that equal to or greater than what is installed; refer to code section FMC504.6. Provide notes to drawings as required. a. If a booster fan is installed and not readily accessible than a label shall be placed adjacent to where the exhaust duct enters the wall. The label shall bear the words: "This dryer exhaust system is equipped with a remotely located booster fan." b. If a dryer is to be used that meets the installed developed length then a label shall be placed adjacent to where the exhaust enters the wall. The label shall bear the words: "This dryer shall meet or exceed the exhausting thru a developed length of *** per the dryer manufacturer's installation instructions." *** shall be the actual developed length installed. 6. The panels on Sheet E-1.16 do not list the specific HP condenser. Revise to list specific HP-A, B, C, P1, P2. 7. The roof plan on E-1.14 does not identify each of the HP condensers. Please add labels to each condenser to list HP-A, B, C, P1 or P2 as well as each condo unit that it serves. 8. Sheet M-1.6: The total number and the number of each type of condensing unit do not match the number of each condo unit type shown on C1.0.1. Ideally each condensing unit on the drawing would contain a label to a specific condo unit as well having the condensing unit affixed with a permanent label identifying the condo unit that it serves.
FD1 COMPLETE 02/03/2006 02/13/2006
Note: Released By: JPATTEE This review is for the building only not for automatic fire sprinkler system, the AFS will require seperate submittles and permitting. Seperate sumittals and permit will also be required for the fire alarm system.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN FEE ¤20.00 03/28/2006
BUILDING CODE ADMIN FUND ¤767.30 03/28/2006
ELECTRIC FEE ¤14,017.80 03/28/2006
FIRE COMM IMPACT FEE 4-1-05 ¤73,783.09 03/28/2006
FIRE PLANS REVIEW ¤1,534.59 03/28/2006
MECHANICAL FEE ¤14,017.80 03/28/2006
PERMIT FEE ¤128,221.50 03/28/2006
PARKS IMPACT FEE 11-2-04 ¤69,496.42 03/28/2006
PLUMBING FEE ¤14,017.80 03/28/2006
RADON FEE ¤767.30 03/28/2006
TRANS IMPACT FEE - CONDO/APT ¤101,646.52 03/28/2006
Fees Total Due: ¤0.00 Total Paid: ¤418,290.12