I want to search for...

Permit #2006020264

Permit Details

Status: COED

Parcel Id: 07-11-31-7007-00280-0040
CONDITIONED SPACE: 1721 sqft
GARAGE: 415 sqft
OPENED PORCH (WITH ROOF) : 200 sqft
OPENED PORCH (WITH ROOF) : 18 sqft
Total Square Footage: 2354 sqft
Block: 00280
Subdivision: -
Job Phone: (386) 445-4515
Location Address: 41 FRANCIS LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/27/2006
NOC: RECORDED
Applicant name: GREGORY LEE LE PERA
Owner: BLASZKA JOSEPH P & BERNADETTE R BLASZKA

Address

15 ROBIN RD

MILFORD, MA 01757

Lot: 0040
Contracted Stated Job Value: ¤86,060.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

WAYNE HOMES BY CENTEX
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

385 DOUGLAS AVE

ALTAMONTE SPRINGS, FL 32714

STE 3000

ALTAMONTE SPRINGS, FL 32714

CBC055301 (Exp: 09/30/2008) (386) 445-4515 (386)446-6285

Sub Contractors

EDWARD DOUGLAS TENNANT
Status Location Address State License Number Phone Fax
INACTIVE

3370 AGRICULTURAL CENTER DRIVE

ST. AUGUSTINE , FL 32092

CAC1813372 (Exp: 08/31/2026) (904)829-8898 (904)829-6587
GARY WAYNE EVERS
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 740106

ORANGE CITY, FL 32763

CFC050566 (Exp: 08/31/2026) 386-775-0909 386-775-0918
GREGORY A HAGEMAN
Status Location Address State License Number Phone
ACTIVE

545 Parque Drive

Ormond Beach, FL 32174

CCC021394 (Exp: 08/31/2026) (386) 672-2821
RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 1963

Bunnell, FL 32110

ER0011613 (Exp: 08/31/2008) (386) 437-0607 (386)437-1847

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 07/26/2006 FINAL APPROVED JGIBSON
UTILITY COMPANY FINAL 07/25/2006 APPROVED TSCHWEERS
STORMWATER FINAL INSPECTION 07/21/2006 APPROVED - AS NOTED DRANDALL
Note: clean trash from left side adj. property
RESIDENTIAL EARLY POWER 06/30/2006 APPROVED RMARVEL
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 06/29/2006 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
LATH /BRICK FLASHING 06/29/2006 CANCELLED BY APPLICANT JGIBSON
DRIVEWAY 06/28/2006 APPROVED BFCHAMBERLAIN
LATH /BRICK FLASHING 05/22/2006 APPROVED CMINI
INSULATION INSPECTION 05/15/2006 APPROVED CMINI
ALL ROUGH 05/05/2006 APPROVED JGIBSON
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/25/2006 CANCELLED BY APPLICANT JMCGOWEN
TEMPORARY POLE 04/25/2006 APPROVED JMCGOWEN
LINTEL 04/13/2006 APPROVED ARAYMOND
Note: THIS IS A REINSPECTION
LINTEL 04/10/2006 Disapproved -FEE REQUIRED ARAYMOND
Note: missing dowel at garage corner, missing cells at entry per detail page 5
FOUNDATION SURVEY APPROVED BY STORMWATER 03/29/2006 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 03/22/2006 APPROVED ARAYMOND
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB INSPECTION/SLAB 03/20/2006 Disapproved -FEE REQUIRED ARAYMOND
Note: NO EVIDENCE OF TERMITE TREATMENT ON SITE. NO APPROVED PLANS ON SITE
FIRST ROUGH PLUMBING INSPECTION 03/17/2006 APPROVED ARAYMOND

Review History

Department Status Date In Date Out
BLD COMPLETE 03/21/2006 03/22/2006
Note: Released By: LWOODROME Stamped replacement plans. Contractor stated that original plans returned to him from the building dept. not stamped with permit #. Questionable. Plan provided back from contractor, did not have Bldg. Dept. plan notes attached, as would be typical of plans that had been through the dept. process. No fee charged.
BLD COMPLETE 02/20/2006 02/23/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 02/17/2006 02/20/2006
Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. The roof loading indicated on the revised sheet 8 does not meet code requirements for general attic space of 10psf live load per FRC Table R301.5. The top chord loading meets the code requirements of Table R301.6 however the bottom chord does not meet the live load requirement of Table R301.5. Please revise the roof loading information on sheet 6 to indicate 10psf bottom chord live load or provide a footnote to the loading table stating that a non-concurrent application of 10lbs bottom chord live load shall be applied to the entire chord.
SW1 COMPLETE 02/08/2006 02/24/2006
Note: Released By: LAPTEKAR
ZON COMPLETE 02/08/2006 02/17/2006
Note: Released By: HHERKERT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 07/26/2006
REINSPECTION FEE ¤40.00 07/26/2006
REINSPECTION FEE ¤40.00 07/26/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 02/27/2006
STORM WATER PERMIT FEES ¤80.00 02/27/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 02/27/2006
ADMIN FEE ¤20.00 02/27/2006
ARC HOUSE REVIEW ¤125.00 02/27/2006
BUILDING CODE ADMIN FUND ¤11.77 02/27/2006
ELECTRIC FEE ¤132.00 02/27/2006
FIRE RES IMPACT FEE 4-1-05 ¤173.47 02/27/2006
MECHANICAL FEE ¤132.00 02/27/2006
PERMIT FEE ¤663.00 02/27/2006
PARKS IMPACT FEE 11-2-04 ¤1,120.91 02/27/2006
PLAN CHECK FEE ¤68.00 02/27/2006
PLUMBING FEE ¤132.00 02/27/2006
RADON FEE ¤11.77 02/27/2006
Fees Total Due: ¤0.00 Total Paid: ¤9,638.43