I want to search for...
Permit #2006020264
Permit Details
Status: COED
| Parcel Id: 07-11-31-7007-00280-0040 |
| CONDITIONED SPACE: 1721 sqft |
| GARAGE: 415 sqft |
| OPENED PORCH (WITH ROOF) : 200 sqft |
| OPENED PORCH (WITH ROOF) : 18 sqft |
| Total Square Footage: 2354 sqft |
| Block: 00280 |
| Subdivision: - |
| Job Phone: (386) 445-4515 |
| Location Address: 41 FRANCIS LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/27/2006 |
| NOC: RECORDED |
| Applicant name: GREGORY LEE LE PERA |
| Owner: BLASZKA JOSEPH P & BERNADETTE R BLASZKA |
|
Address 15 ROBIN RD MILFORD, MA 01757 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤86,060.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
WAYNE HOMES BY CENTEX
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
385 DOUGLAS AVE ALTAMONTE SPRINGS, FL 32714 |
STE 3000 ALTAMONTE SPRINGS, FL 32714 |
CBC055301 (Exp: 09/30/2008) | (386) 445-4515 | (386)446-6285 |
Sub Contractors
EDWARD DOUGLAS TENNANT
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
3370 AGRICULTURAL CENTER DRIVE ST. AUGUSTINE , FL 32092 |
CAC1813372 (Exp: 08/31/2026) | (904)829-8898 | (904)829-6587 |
GARY WAYNE EVERS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 740106 ORANGE CITY, FL 32763 |
CFC050566 (Exp: 08/31/2026) | 386-775-0909 | 386-775-0918 |
GREGORY A HAGEMAN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
545 Parque Drive Ormond Beach, FL 32174 |
CCC021394 (Exp: 08/31/2026) | (386) 672-2821 |
RICHARD H SIMMONS JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P. O. Box 1963 Bunnell, FL 32110 |
ER0011613 (Exp: 08/31/2008) | (386) 437-0607 | (386)437-1847 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 07/26/2006 | FINAL APPROVED | JGIBSON |
| UTILITY COMPANY FINAL | 07/25/2006 | APPROVED | TSCHWEERS |
| STORMWATER FINAL INSPECTION | 07/21/2006 | APPROVED - AS NOTED | DRANDALL |
| Note: clean trash from left side adj. property | |||
| RESIDENTIAL EARLY POWER | 06/30/2006 | APPROVED | RMARVEL |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 06/29/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 06/29/2006 | CANCELLED BY APPLICANT | JGIBSON |
| DRIVEWAY | 06/28/2006 | APPROVED | BFCHAMBERLAIN |
| LATH /BRICK FLASHING | 05/22/2006 | APPROVED | CMINI |
| INSULATION INSPECTION | 05/15/2006 | APPROVED | CMINI |
| ALL ROUGH | 05/05/2006 | APPROVED | JGIBSON |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/25/2006 | CANCELLED BY APPLICANT | JMCGOWEN |
| TEMPORARY POLE | 04/25/2006 | APPROVED | JMCGOWEN |
| LINTEL | 04/13/2006 | APPROVED | ARAYMOND |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 04/10/2006 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: missing dowel at garage corner, missing cells at entry per detail page 5 | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 03/29/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 03/22/2006 | APPROVED | ARAYMOND |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 03/20/2006 | Disapproved -FEE REQUIRED | ARAYMOND |
| Note: NO EVIDENCE OF TERMITE TREATMENT ON SITE. NO APPROVED PLANS ON SITE | |||
| FIRST ROUGH PLUMBING INSPECTION | 03/17/2006 | APPROVED | ARAYMOND |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/21/2006 | 03/22/2006 |
| Note: Released By: LWOODROME Stamped replacement plans. Contractor stated that original plans returned to him from the building dept. not stamped with permit #. Questionable. Plan provided back from contractor, did not have Bldg. Dept. plan notes attached, as would be typical of plans that had been through the dept. process. No fee charged. | |||
| BLD | COMPLETE | 02/20/2006 | 02/23/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | HOLD | 02/17/2006 | 02/20/2006 |
| Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. The roof loading indicated on the revised sheet 8 does not meet code requirements for general attic space of 10psf live load per FRC Table R301.5. The top chord loading meets the code requirements of Table R301.6 however the bottom chord does not meet the live load requirement of Table R301.5. Please revise the roof loading information on sheet 6 to indicate 10psf bottom chord live load or provide a footnote to the loading table stating that a non-concurrent application of 10lbs bottom chord live load shall be applied to the entire chord. | |||
| SW1 | COMPLETE | 02/08/2006 | 02/24/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 02/08/2006 | 02/17/2006 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 07/26/2006 |
| REINSPECTION FEE | ¤40.00 | 07/26/2006 |
| REINSPECTION FEE | ¤40.00 | 07/26/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 02/27/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 02/27/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 02/27/2006 |
| ADMIN FEE | ¤20.00 | 02/27/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 02/27/2006 |
| BUILDING CODE ADMIN FUND | ¤11.77 | 02/27/2006 |
| ELECTRIC FEE | ¤132.00 | 02/27/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 02/27/2006 |
| MECHANICAL FEE | ¤132.00 | 02/27/2006 |
| PERMIT FEE | ¤663.00 | 02/27/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 02/27/2006 |
| PLAN CHECK FEE | ¤68.00 | 02/27/2006 |
| PLUMBING FEE | ¤132.00 | 02/27/2006 |
| RADON FEE | ¤11.77 | 02/27/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,638.43 |