I want to search for...
Permit #2006020353
Permit Details
Status: COED
| Parcel Id: 07-11-31-7020-00040-0390 |
| CONDITIONED SPACE: 2701 sqft |
| GARAGE: 635 sqft |
| OPENED PORCH (WITH ROOF) : 380 sqft |
| OPENED PORCH (WITH ROOF) : 90 sqft |
| Total Square Footage: 3806 sqft |
| Block: 00040 |
| Subdivision: - |
| Job Phone: (386) 445-2222 |
| Location Address: 32 WEBWOOD PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/13/2006 |
| NOC: RECORDED |
| Applicant name: MICHAEL STEPHAN MULLEN |
| Owner: POZNYAK IGOR & YELENA POZNYAK |
|
Address 18 BUTTERMILK DRIVE PALM COAST, FL 32137 |
| Lot: 0390 |
| Contracted Stated Job Value: ¤150,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
TOWN & COUNTRY HOMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1 Enterprise Drive Bunnell, FL 32110 |
CGC049972 (Exp: 08/31/2026) | (386) 445-2222 |
Sub Contractors
STEVEN DUANE DENSLOW
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. US # 1 Ormond Beach, FL 32174 |
EC0001678 (Exp: 08/31/2012) | (386) 672-8494 | (386)673-7856 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
DENNIS GENE GAINEY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P.O. BOX 1203 Bunnell, FL 32110 |
CFC046004 (Exp: 08/31/2026) | (386) 437-5637 | 386-437-3012 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 02/26/2007 | FINAL APPROVED | JMCGOWEN |
| FINAL COMPLETE BUILDING INSPECTION | 02/23/2007 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: MASTER SHOWER DRAIN IS NOT COMPLETE, PORCH SWITCH IN MASTER BEDROOM IS NOT ON ARC FAULT | |||
| STORMWATER FINAL INSPECTION | 02/22/2007 | APPROVED - AS NOTED | DRANDALL |
| Note: THIS IS A REINSPECTION 30 s.f. road damage $340 | |||
| STORMWATER FINAL INSPECTION | 02/14/2007 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: place sod on all disturbed earth on drainage ditch rear.....remove silt fence rear.....remove pallots & trash from right swale and street.....sweep street.....30 sf road damage | |||
| UTILITY COMPANY FINAL | 02/09/2007 | APPROVED | MBACON |
| RESIDENTIAL EARLY POWER | 02/06/2007 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| RESIDENTIAL EARLY POWER | 01/31/2007 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: 2NEED TO BOX AND SECURE ALL LOOSE WIRES. BLANK OFF OPEN BOXES. COLOR CODE WHITE HOT CONDUCTORS A/C DISSCONNECT. | |||
| PRE DRIVEWAY | 01/19/2007 | APPROVED | DRANDALL |
| LATH /BRICK FLASHING | 11/30/2006 | APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 11/21/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: NEED TO HAVE TWO LAYERS OF MOISTURE BARRIER BEHIND LATH. BARE WOOD SHOWING. NEXT HOUSE BLOCK CANNOT BE STUCCOED BEFORE INSPECTION. | |||
| INSULATION INSPECTION | 11/15/2006 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 11/13/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Missing insulation @ entry arch, fire block around 2'' vent stack in master bath vanity. | |||
| INSULATION INSPECTION | 11/08/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: NEED TO FIREBLOCK ALL CHASE WALLS AND PENATRATIONS LEADING TO ATTIC SPACE. NEED MIN. 4" CLEARACE BETWEEN AIR DUCTS COMING OUT OF CEILING IN GARAGE. NEED TO FULLY SEAL OFF ELECTRIC PANEL IN GARAGE. | |||
| ALL ROUGH | 11/01/2006 | APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 10/03/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: need 4" min.space between ducts in garage. NEED TO REPLACE NON PT WITH P.T. PLATE TOP OF TUFF-R IN LAUNDRY. FIRESTOP NEEDED IN CHASE WALLS LEADING TO ATTIC SPACE. NEED DETAIL SHOWING DOOR ATTACHEMENT AT CMU WALL TO PLYWOOD. NEED TO PUT PLUMBING PIPE IN WALL AT LAUNDRY. NEED TO PHASE WHITE UNGROUNDED WIRES IN BOXES. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/15/2006 | APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| TEMPORARY POLE | 08/07/2006 | APPROVED | RMARVEL |
| Note: CALLED FPL NANCY AT 3:08 | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/04/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. GABLE-END TRUSS IN GARAGE/ THE NAILING OF STRAPS ARE MISSING THE TRUSS WEB AND MISSING BLOCKING AT ENDS WHERE STRAPS NAIL THROUGH OSB ONLY 2. SHEARWALL-RIGHT SIDE OF GARAGE/ ADD 3 STUDS (1 EACH) STUDS UNDER 3 TRUSSES MORE THAN 5 1/2" FROM LAST STUD/ SEE BLACK X's ON STUDS 3. LEFT REAR BEDROOM/ LEFT GABLE STRAP NOT NAILED TO BLOCKING 4. X-BRACING ABOVE FRONT DOOR ENTRY MISSING | |||
| LINTEL | 07/07/2006 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 06/28/2006 | Disapproved -FEE REQUIRED | ARITTER |
| Note: Front wall changed- revised plans & submit, clean out all cells. | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 05/30/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 05/12/2006 | APPROVED | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 04/26/2006 | APPROVED | JLEVRAULT |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/30/2006 | 10/31/2006 |
| Note: Released By: CCOTE Approved for Release. REVISION: Pocket for sliding glass door detail. | |||
| BLD | COMPLETE | 07/18/2006 | 07/18/2006 |
| Note: Released By: LWOODROME Revision: Dining room windows, add a door @ rear | |||
| BLD | COMPLETE | 03/06/2006 | 03/07/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R. | |||
| ZON | COMPLETE | 02/17/2006 | 02/17/2006 |
| Note: Released By: HHERKERT | |||
| BLD | HOLD | 02/17/2006 | 02/21/2006 |
| Note: Held By: FREODICA 1. Provide detail/section at entry showing elevations, & lintel connections to wall. 2. Clarify location of interior bearing wall/point. Floor plan does not match with foundation plan & roof (truss) plan. 3. Indicate location & size of post where HGT-2 connector for girder truss GDR01 is connected. How are they tied down to post to carry load down to foundation. | |||
| SW1 | COMPLETE | 02/09/2006 | 03/10/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | HOLD | 02/09/2006 | 02/16/2006 |
| Note: Held By: HHERKERT hold for ARC meeting 2-17-06 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤340.00 | 02/26/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 02/26/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 02/26/2007 |
| REINSPECTION FEE | ¤40.00 | 02/26/2007 |
| REINSPECTION FEE | ¤40.00 | 02/26/2007 |
| REINSPECTION FEE | ¤40.00 | 02/26/2007 |
| REINSPECTION FEE | ¤40.00 | 02/26/2007 |
| REINSPECTION FEE | ¤40.00 | 02/26/2007 |
| REINSPECTION FEE | ¤40.00 | 02/26/2007 |
| REINSPECTION FEE | ¤40.00 | 02/26/2007 |
| REINSPECTION FEE | ¤40.00 | 02/26/2007 |
| REVISION | ¤40.00 | 02/26/2007 |
| REVISION | ¤40.00 | 02/26/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 02/26/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 03/13/2006 |
| ADMIN FEE | ¤20.00 | 03/13/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 03/13/2006 |
| BUILDING CODE ADMIN FUND | ¤19.03 | 03/13/2006 |
| ELECTRIC FEE | ¤191.40 | 03/13/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 03/13/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/13/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 03/13/2006 |
| MECHANICAL FEE | ¤191.40 | 03/13/2006 |
| PERMIT FEE | ¤1,049.10 | 03/13/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 03/13/2006 |
| PLAN CHECK FEE | ¤107.60 | 03/13/2006 |
| PLUMBING FEE | ¤191.40 | 03/13/2006 |
| RADON FEE | ¤19.03 | 03/13/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,991.85 |