I want to search for...

Permit #2006020353

Permit Details

Status: COED

Parcel Id: 07-11-31-7020-00040-0390
CONDITIONED SPACE: 2701 sqft
GARAGE: 635 sqft
OPENED PORCH (WITH ROOF) : 380 sqft
OPENED PORCH (WITH ROOF) : 90 sqft
Total Square Footage: 3806 sqft
Block: 00040
Subdivision: -
Job Phone: (386) 445-2222
Location Address: 32 WEBWOOD PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/13/2006
NOC: RECORDED
Applicant name: MICHAEL STEPHAN MULLEN
Owner: POZNYAK IGOR & YELENA POZNYAK

Address

18 BUTTERMILK DRIVE

PALM COAST, FL 32137

Lot: 0390
Contracted Stated Job Value: ¤150,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

TOWN & COUNTRY HOMES
Status Location Address State License Number Phone
ACTIVE

1 Enterprise Drive

Bunnell, FL 32110

CGC049972 (Exp: 08/31/2026) (386) 445-2222

Sub Contractors

STEVEN DUANE DENSLOW
Status Location Address State License Number Phone Fax
CANCEL

400 N. US # 1

Ormond Beach, FL 32174

EC0001678 (Exp: 08/31/2012) (386) 672-8494 (386)673-7856
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
DENNIS GENE GAINEY
Status Location Address State License Number Phone Fax
INACTIVE

P.O. BOX 1203

Bunnell, FL 32110

CFC046004 (Exp: 08/31/2026) (386) 437-5637 386-437-3012

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 02/26/2007 FINAL APPROVED JMCGOWEN
FINAL COMPLETE BUILDING INSPECTION 02/23/2007 Disapproved -FEE REQUIRED JHINDMAN
Note: MASTER SHOWER DRAIN IS NOT COMPLETE, PORCH SWITCH IN MASTER BEDROOM IS NOT ON ARC FAULT
STORMWATER FINAL INSPECTION 02/22/2007 APPROVED - AS NOTED DRANDALL
Note: THIS IS A REINSPECTION 30 s.f. road damage $340
STORMWATER FINAL INSPECTION 02/14/2007 Disapproved -FEE REQUIRED DRANDALL
Note: place sod on all disturbed earth on drainage ditch rear.....remove silt fence rear.....remove pallots & trash from right swale and street.....sweep street.....30 sf road damage
UTILITY COMPANY FINAL 02/09/2007 APPROVED MBACON
RESIDENTIAL EARLY POWER 02/06/2007 APPROVED LHITES
Note: THIS IS A REINSPECTION
RESIDENTIAL EARLY POWER 01/31/2007 Disapproved -FEE REQUIRED RMARVEL
Note: 2NEED TO BOX AND SECURE ALL LOOSE WIRES. BLANK OFF OPEN BOXES. COLOR CODE WHITE HOT CONDUCTORS A/C DISSCONNECT.
PRE DRIVEWAY 01/19/2007 APPROVED DRANDALL
LATH /BRICK FLASHING 11/30/2006 APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
LATH /BRICK FLASHING 11/21/2006 Disapproved -FEE REQUIRED CMINI
Note: NEED TO HAVE TWO LAYERS OF MOISTURE BARRIER BEHIND LATH. BARE WOOD SHOWING. NEXT HOUSE BLOCK CANNOT BE STUCCOED BEFORE INSPECTION.
INSULATION INSPECTION 11/15/2006 APPROVED JLEVRAULT
Note: THIS IS A REINSPECTION
INSULATION INSPECTION 11/13/2006 Disapproved -FEE REQUIRED JGIBSON
Note: Missing insulation @ entry arch, fire block around 2'' vent stack in master bath vanity.
INSULATION INSPECTION 11/08/2006 Disapproved -FEE REQUIRED CMINI
Note: NEED TO FIREBLOCK ALL CHASE WALLS AND PENATRATIONS LEADING TO ATTIC SPACE. NEED MIN. 4" CLEARACE BETWEEN AIR DUCTS COMING OUT OF CEILING IN GARAGE. NEED TO FULLY SEAL OFF ELECTRIC PANEL IN GARAGE.
ALL ROUGH 11/01/2006 APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
ALL ROUGH 10/03/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: need 4" min.space between ducts in garage. NEED TO REPLACE NON PT WITH P.T. PLATE TOP OF TUFF-R IN LAUNDRY. FIRESTOP NEEDED IN CHASE WALLS LEADING TO ATTIC SPACE. NEED DETAIL SHOWING DOOR ATTACHEMENT AT CMU WALL TO PLYWOOD. NEED TO PUT PLUMBING PIPE IN WALL AT LAUNDRY. NEED TO PHASE WHITE UNGROUNDED WIRES IN BOXES.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/15/2006 APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
TEMPORARY POLE 08/07/2006 APPROVED RMARVEL
Note: CALLED FPL NANCY AT 3:08
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/04/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. GABLE-END TRUSS IN GARAGE/ THE NAILING OF STRAPS ARE MISSING THE TRUSS WEB AND MISSING BLOCKING AT ENDS WHERE STRAPS NAIL THROUGH OSB ONLY 2. SHEARWALL-RIGHT SIDE OF GARAGE/ ADD 3 STUDS (1 EACH) STUDS UNDER 3 TRUSSES MORE THAN 5 1/2" FROM LAST STUD/ SEE BLACK X's ON STUDS 3. LEFT REAR BEDROOM/ LEFT GABLE STRAP NOT NAILED TO BLOCKING 4. X-BRACING ABOVE FRONT DOOR ENTRY MISSING
LINTEL 07/07/2006 APPROVED JLEVRAULT
Note: THIS IS A REINSPECTION
LINTEL 06/28/2006 Disapproved -FEE REQUIRED ARITTER
Note: Front wall changed- revised plans & submit, clean out all cells.
FOUNDATION SURVEY APPROVED BY STORMWATER 05/30/2006 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 05/12/2006 APPROVED CMINI
FIRST ROUGH PLUMBING INSPECTION 04/26/2006 APPROVED JLEVRAULT

Review History

Department Status Date In Date Out
BLD COMPLETE 10/30/2006 10/31/2006
Note: Released By: CCOTE Approved for Release. REVISION: Pocket for sliding glass door detail.
BLD COMPLETE 07/18/2006 07/18/2006
Note: Released By: LWOODROME Revision: Dining room windows, add a door @ rear
BLD COMPLETE 03/06/2006 03/07/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R.
ZON COMPLETE 02/17/2006 02/17/2006
Note: Released By: HHERKERT
BLD HOLD 02/17/2006 02/21/2006
Note: Held By: FREODICA 1. Provide detail/section at entry showing elevations, & lintel connections to wall. 2. Clarify location of interior bearing wall/point. Floor plan does not match with foundation plan & roof (truss) plan. 3. Indicate location & size of post where HGT-2 connector for girder truss GDR01 is connected. How are they tied down to post to carry load down to foundation.
SW1 COMPLETE 02/09/2006 03/10/2006
Note: Released By: LAPTEKAR
ZON HOLD 02/09/2006 02/16/2006
Note: Held By: HHERKERT hold for ARC meeting 2-17-06

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤340.00 02/26/2007
EARLY POWER INSPECTION ¤40.00 02/26/2007
EARLY POWER INSPECTION ¤40.00 02/26/2007
REINSPECTION FEE ¤40.00 02/26/2007
REINSPECTION FEE ¤40.00 02/26/2007
REINSPECTION FEE ¤40.00 02/26/2007
REINSPECTION FEE ¤40.00 02/26/2007
REINSPECTION FEE ¤40.00 02/26/2007
REINSPECTION FEE ¤40.00 02/26/2007
REINSPECTION FEE ¤40.00 02/26/2007
REINSPECTION FEE ¤40.00 02/26/2007
REVISION ¤40.00 02/26/2007
REVISION ¤40.00 02/26/2007
STORMWATER REINSPECTION FEE ¤35.00 02/26/2007
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 03/13/2006
ADMIN FEE ¤20.00 03/13/2006
ARC HOUSE REVIEW ¤125.00 03/13/2006
BUILDING CODE ADMIN FUND ¤19.03 03/13/2006
ELECTRIC FEE ¤191.40 03/13/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 03/13/2006
STORM WATER PERMIT FEES ¤80.00 03/13/2006
FIRE RES IMPACT FEE 4-1-05 ¤173.47 03/13/2006
MECHANICAL FEE ¤191.40 03/13/2006
PERMIT FEE ¤1,049.10 03/13/2006
PARKS IMPACT FEE 11-2-04 ¤1,120.91 03/13/2006
PLAN CHECK FEE ¤107.60 03/13/2006
PLUMBING FEE ¤191.40 03/13/2006
RADON FEE ¤19.03 03/13/2006
Fees Total Due: ¤0.00 Total Paid: ¤10,991.85