I want to search for...
Permit #2006020441
Permit Details
Status: COED
| Parcel Id: 07-11-31-7035-00760-0140 |
| CONDITIONED SPACE: 1274 sqft |
| CONDITIONED SPACE: 1274 sqft |
| GARAGE: 255 sqft |
| GARAGE: 255 sqft |
| OPENED PORCH (WITH ROOF) : 129 sqft |
| OPENED PORCH (WITH ROOF) : 129 sqft |
| OPENED PORCH (WITH ROOF) : 32 sqft |
| OPENED PORCH (WITH ROOF) : 32 sqft |
| Total Square Footage: 3380 sqft |
| Block: 00760 |
| Subdivision: - |
| Job Phone: (386)447-8680 |
| Location Address: 18 BUTTONBUSH LN |
| Type: DU - DUPLEX |
| Issue Date: 03/14/2006 |
| NOC: RECORDED |
| Applicant name: MICHAEL LEO BRANIFF |
| Owner: ART & PATRICIA KIEFFER |
|
Address 9 ELM PLACE MATAWAN, NJ 07747 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤202,800.00 |
| Job Description: DUPLEX |
| Type: CN |
Contractor
RIVER CITY HOMES
| Status | Location Address | State License Number | Phone |
| CANCEL |
12058 SAN JOSE BLVD #804 Jacksonville, FL 32223 |
CGC062728 (Exp: 08/31/2012) | 904-260-9009 |
Sub Contractors
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 1009 BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2014) | (386) 931-2568 | 386-313-3445 |
MICHAEL DAVID CLARK
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Box 918 Bunnell, FL 32110 |
CAC044867 (Exp: 09/30/2008) | (386) 437-2001 |
SCOTT RICHARD GATTIE
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1508 CLAPTON DR DELAND, FL 32720 |
CFC057990 (Exp: 08/31/2010) | (386)740-9227 | (386)740-9228 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 11/08/2006 | FINAL APPROVED | ACOOPER |
| UTILITY COMPANY FINAL | 10/10/2006 | APPROVED | JSHEVLIN |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 10/05/2006 | Disapproved - NO FEE | JSHEVLIN |
| Note: FAILED BACK PEP TANK IS CRUSHED AND FILLED WITH DIRT BALL VALVE PIT IS SINKING OUR OF GROUND AND 7 FT OF LINE EXPOSED | |||
| FIREWALL INSPECTION | 10/05/2006 | APPROVED | JGIBSON |
| STORMWATER FINAL INSPECTION | 10/04/2006 | APPROVED - AS NOTED | DRANDALL |
| Note: 28 sf road damage | |||
| RESIDENTIAL EARLY POWER | 10/04/2006 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| RESIDENTIAL EARLY POWER | 09/27/2006 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: No print, no paperwork in box, Side - A recepticle under the sink for the disposal was out of the wall. | |||
| DRIVEWAY | 09/12/2006 | APPROVED | DRANDALL |
| INSULATION INSPECTION | 07/18/2006 | APPROVED | ARITTER |
| ALL ROUGH | 07/13/2006 | APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 07/10/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. MOUNT/RECESS/ ALL EXTERIOR OUTLETS 2. NO PRESSURE AT 2ND ROUGH PLMB. 3. ATTACH MAIN FEEDERS ABOVE PANELS/ GARAGE WITH CONNECTORS 4. PATCH AROUND ELECTRIC THROUGH FIREWALL | |||
| LATH /BRICK FLASHING | 07/07/2006 | APPROVED | MMOORE |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 06/23/2006 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| FIREWALL FRAMING (DUPLEX) | 06/06/2006 | APPROVED | PGALLMANN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 06/06/2006 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: 1) LEFT UNIT: TRUSS A5 IS DAMAGED (gussett, bottom cord, web) LOCATED ABOVE THE MASTER WALK-IN CLOSET. ENGINEER'S LETTER OF REPAIR, APPROVED BY CITY, IS NEEDED. 2) BOTH UNITS: UPLIFT STRAPS ARE MISSING @ FRONT ENTRY ON TRUSSES A6 & A7. 3) RIGHT UNIT: THERE ARE GAPS BETWEEN 3-PLY TRUSS A1. | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 05/31/2006 | APPROVED | WKINELL |
| LINTEL | 05/17/2006 | APPROVED | ARITTER |
| Note: This inspection weas done as a Lintel. It was approve on 5/13/2006 | |||
| PARTIAL TIE BEAM/LINTEL | 05/17/2006 | APPROVED | ARITTER |
| Note: THIS IS A REINSPECTION | |||
| PARTIAL TIE BEAM/LINTEL | 05/16/2006 | Disapproved -FEE REQUIRED | ARITTER |
| Note: misssing cell marked on the lan. | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 05/03/2006 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 04/27/2006 | APPROVED | JLEVRAULT |
Review History
| Department | Status | Date In | Date Out |
| SW1 | CANCEL | 09/08/2006 | |
| SW1 | HOLD | 08/04/2006 | 08/04/2006 |
| Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy. Please re-submit all signed sealed suveys associated with this property showing corrected elevations. We check all surveys against the city's as-built drawings corrected to NAVD 1988. The elevations are different than we expected by 2.21ft. | |||
| BLD | COMPLETE | 06/15/2006 | 06/20/2006 |
| Note: Released By: LWOODROME Revision: Truss repair | |||
| BLD | COMPLETE | 02/24/2006 | 03/02/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba | |||
| ZON | HOLD | 02/14/2006 | 02/20/2006 |
| Note: Held By: HHERKERT hold for ARC meeting 2-24-06 | |||
| SW1 | COMPLETE | 02/14/2006 | 03/02/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 02/24/2006 | |
| Note: Released By: ECOYNE |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤324.00 | 11/09/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 11/09/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 11/09/2006 |
| REINSPECTION FEE | ¤40.00 | 11/09/2006 |
| REINSPECTION FEE | ¤40.00 | 11/09/2006 |
| REINSPECTION FEE | ¤40.00 | 11/09/2006 |
| REINSPECTION FEE | ¤40.00 | 11/09/2006 |
| REVISION | ¤40.00 | 11/09/2006 |
| SW REVISION | ¤40.00 | 11/09/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤6,497.02 | 03/14/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤7,200.00 | 03/14/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/14/2006 |
| ADMIN FEE | ¤20.00 | 03/14/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 03/14/2006 |
| BUILDING CODE ADMIN FUND | ¤16.90 | 03/14/2006 |
| ELECTRIC FEE | ¤178.20 | 03/14/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤346.94 | 03/14/2006 |
| MECHANICAL FEE | ¤178.20 | 03/14/2006 |
| PERMIT FEE | ¤963.30 | 03/14/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤2,241.82 | 03/14/2006 |
| PLAN CHECK FEE | ¤98.80 | 03/14/2006 |
| PLUMBING FEE | ¤178.20 | 03/14/2006 |
| RADON FEE | ¤16.90 | 03/14/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤18,785.28 |