I want to search for...

Permit #2006020471

Permit Details

Status: COED

Parcel Id: 07-11-31-7028-00700-0040
CONDITIONED SPACE: 2154 sqft
GARAGE: 442 sqft
OPENED PORCH (WITH ROOF) : 162 sqft
OPENED PORCH (WITH ROOF) : 62 sqft
Total Square Footage: 2820 sqft
Block: 00700
Subdivision: -
Job Phone: (386)437-5782
Location Address: 8 POINFIELD PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/27/2006
NOC: RECORDED
Applicant name: SANDRA LEE FRENCH
Owner: WEIDL SHELLEY A

Address

8 POINFIELD DRIVE

PALM COAST, FL 32164

Lot: 0040
Contracted Stated Job Value: ¤150,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SANDEX HOMES
Status Location Address State License Number Phone Fax
CANCEL

27 EGAN DR

PALM COAST, FL

CRC1327302 (Exp: 09/30/2008) (386)437-5782 (386)437-5782

Sub Contractors

STEVEN JAY SMITH
Status Location Address State License Number Phone
INACTIVE

104 West Cedar Avenue

Orange City, FL 32763

EC0001542 (Exp: 08/31/2022) (386)775-7776
MICHAEL DAVID CLARK
Status Location Address State License Number Phone
CANCEL

P. O. Box 918

Bunnell, FL 32110

CAC044867 (Exp: 09/30/2008) (386) 437-2001
BARRY D MARTIN
Status Location Address State License Number Phone Fax
CANCEL

1650 N STATE STREET

Bunnell, FL 32110

CCC033728 (Exp: 08/31/2020) (386) 437-7700 (386)437-7701
BRUCE EDWARD HAWKESWORTH
Status Location Address State License Number Phone
CANCEL

671 Dara Circle

DELTONA, FL 32735

CFC053329 (Exp: 09/30/2008) (386) 228-2784

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 03/01/2007 FINAL APPROVED JHINDMAN
STORMWATER FINAL INSPECTION 02/28/2007 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION 22 FEET ROAD DAMAGE , = 276.00
STORMWATER FINAL INSPECTION 02/27/2007 Disapproved -FEE REQUIRED GLALIMA
Note: REGRADE AT LEFT SIDE FRONT CORNER , AND AT TANK SO WATER MAKES IT TO SWALE .
UTILITY COMPANY FINAL 02/22/2007 APPROVED MBACON
DRIVEWAY 02/02/2007 APPROVED GLALIMA
LATH /BRICK FLASHING 12/04/2006 APPROVED CMINI
INSULATION INSPECTION 12/04/2006 APPROVED CMINI
ALL ROUGH 11/30/2006 APPROVED JHINDMAN
Note:
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/03/2006 APPROVED PGALLMANN
LINTEL 08/18/2006 APPROVED CMINI
FOUNDATION SURVEY APPROVED BY STORMWATER 08/17/2006 APPROVED LAPTEKAR
MONOLITHIC SLAB INSPECTION/SLAB 08/03/2006 APPROVED RMARVEL
FIRST ROUGH PLUMBING INSPECTION 08/01/2006 APPROVED ARITTER

Review History

Department Status Date In Date Out
BLD COMPLETE 08/31/2006 08/31/2006
Note: Released By: CCOTE Approved for Release. REVISION: Revised truss layout, truss package and connector schedule.
BLD COMPLETE 03/22/2006 03/29/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 02/24/2006 03/02/2006
Note: Held By: CCOTE The following items must be submitted in order to complete Building Permit Application plan review. 1. The lintel values included on the load tables do not match those in the latest Cast-Crete literature. Please indicate manufacture used, if Cast-Crete then update values in load tables. 2. The Lintel Type "AA" states lintel no steel (bond beam top course). It appears to show hatching. Please clarify whether this is an 8F8 or and 8U8. Please add this to the description above lintel on drawing. 3. The Lintel Type "A" states bond beam only. It appears to show hatching and a steel bar at the bottom and Cast-Crete only has an option for steel at the top or top & bottom. Please clarify whether this is a cast in place lintel or a precast lintel. If it is a precast lintel clarify whether this is an 8F8-0B/1T. Please add this to the description above lintel on drawing. 4. The Lintel Type "B" states lintel w/ steel (bond beam top course). It appears to show hatching and a steel bar at the bottom and Cast-Crete only has an option for steel at the top or top & bottom. Please clarify whether this is an 8F8-0B/1T. Please add this to the description above lintel on drawing. What is different than lintel type "A". 5. The Lintel Type "C" states lintel w/ steel (bond beam top course). Please clarify whether this is an 8F16-1B/1T. Please add this to the description above lintel on drawing. 6. The elevations do not indicate all of the various window head heights. Please add these dimensions to the elevations. 7. The drawings do not indicate truss uplift connectors to be used for each truss. A list of some connectors is located on sheet D3 but this is not sufficient because it only contains generic uplift values. Please submit a project specific truss connector schedule listing connector(s) to be used for each connection point for each truss as well connectors to be used for other items including but not limited to beams, columns and hand framed members.
SW1 COMPLETE 02/14/2006 03/10/2006
Note: Released By: LAPTEKAR
ZON HOLD 02/14/2006 02/20/2006
Note: Held By: HHERKERT 1. landscape plan indicating plant location, plant types, and quantities required 2. hold for ARC meeting 2-24-06
ZON COMPLETE 02/24/2006
Note: Released By: ECOYNE

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤276.00 03/01/2007
REVISION ¤40.00 02/28/2007
STORMWATER REINSPECTION FEE ¤35.00 02/28/2007
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 07/27/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 07/27/2006
STORM WATER PERMIT FEES ¤80.00 07/27/2006
ADMIN FEE ¤20.00 07/27/2006
ARC HOUSE REVIEW ¤125.00 07/27/2006
BUILDING CODE ADMIN FUND ¤14.10 07/27/2006
ELECTRIC FEE ¤154.80 07/27/2006
FIRE RES IMPACT FEE 4-1-05 ¤173.47 07/27/2006
MECHANICAL FEE ¤154.80 07/27/2006
PERMIT FEE ¤811.20 07/27/2006
PARKS IMPACT FEE 11-2-04 ¤1,120.91 07/27/2006
PLAN CHECK FEE ¤83.20 07/27/2006
PLUMBING FEE ¤154.80 07/27/2006
RADON FEE ¤14.10 07/27/2006
Fees Total Due: ¤0.00 Total Paid: ¤10,105.89