I want to search for...

Permit #2006020605

Permit Details

Status: COED

Parcel Id: 07-11-31-7030-00770-0090
CONDITIONED SPACE: 2050 sqft
GARAGE: 455 sqft
OPENED PORCH (WITH ROOF) : 185 sqft
OPENED PORCH (WITH ROOF) : 45 sqft
Total Square Footage: 2735 sqft
Block: 00770
Subdivision: -
Job Phone: (386)447-8680
Location Address: 11 RAMBLING LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/31/2006
NOC: RECORDED
Applicant name: MICHAEL LEO BRANIFF
Owner: SAGHEER & LINDA RIZVI

Address

7825 SW 72ND AVE

MIAMI, FL 33143

Lot: 0090
Contracted Stated Job Value: ¤191,450.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

RIVER CITY HOMES
Status Location Address State License Number Phone
CANCEL

12058 SAN JOSE BLVD #804

Jacksonville, FL 32223

CGC062728 (Exp: 08/31/2012) 904-260-9009

Sub Contractors

PETER JOSEPH LYDEN
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 1009

BUNNELL, FL 32110

EC0002436 (Exp: 08/31/2014) (386) 931-2568 386-313-3445
SCOTT RICHARD GATTIE
Status Location Address State License Number Phone Fax
CANCEL

1508 CLAPTON DR

DELAND, FL 32720

CFC057990 (Exp: 08/31/2010) (386)740-9227 (386)740-9228
MICHAEL DAVID CLARK
Status Location Address State License Number Phone
CANCEL

P. O. Box 918

Bunnell, FL 32110

CAC044867 (Exp: 09/30/2008) (386) 437-2001
BARRY D MARTIN
Status Location Address State License Number Phone Fax
CANCEL

1650 N STATE STREET

Bunnell, FL 32110

CCC033728 (Exp: 08/31/2020) (386) 437-7700 (386)437-7701

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 11/07/2006 FINAL APPROVED JHINDMAN
UTILITY COMPANY FINAL 11/02/2006 APPROVED TREESE
STORMWATER FINAL INSPECTION 11/01/2006 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION 24 FEET ROAD DAMAGE . = 292.00
UTILITY COMPANY FINAL 11/01/2006 Disapproved - NO FEE MBACON
Note: FAILED, NO CLEAN OUT BEHIND TANK
RESIDENTIAL EARLY POWER 11/01/2006 APPROVED JHINDMAN
Note:
STORMWATER FINAL INSPECTION 10/30/2006 Disapproved -FEE REQUIRED GLALIMA
Note: CLEAN ALL OF ROAD SO I CAN ASSESS DAMAGE . MAKE A MORE DEFINED SWALE . RIGHT SIDE FROM CENTER
DRIVEWAY 09/14/2006 APPROVED GLALIMA
LATH /BRICK FLASHING 09/06/2006 CANCELLED BY INSPECTOR JHINDMAN
Note: already passed
LATH /BRICK FLASHING 09/05/2006 APPROVED JHINDMAN
INSULATION INSPECTION 08/28/2006 APPROVED ACOOPER
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/22/2006 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
ALL ROUGH 08/22/2006 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/18/2006 Disapproved -FEE REQUIRED JHINDMAN
Note: THIS IS A REINSPECTION truss e04 htt16s still missing at sill plate.
ALL ROUGH 08/18/2006 Disapproved - NO FEE JHINDMAN
Note: cannot pass rough until roof sheathing passes
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/09/2006 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION.3,hts30s still missing each side of truss e-04 to post. htt16 still needed at sill per plan.threaded rods still loose in areas.mgt nut still loose over tub.loose sheets check marked walls. not ready.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 07/28/2006 Disapproved -FEE REQUIRED CMINI
Note: NEED TO TIGHTEN THREADED RODS.MISSING PARALLAM POSTS PER PLAN. MISSING 3 HTS30 STRAPS EACH SIDE OF TRUSS E-04,HTT16 AT SILL PER PLAN. MGT NUT LOOSE AT BD.RM. #3,LOOSE SHEETS AT BD.RM.#2,#3. NEED TO OVERLAP TOP PLATES AT EXT.NOOK 45 WALL. NOT READY.
LINTEL 07/07/2006 APPROVED CMINI
PARTIAL TIE BEAM/LINTEL 07/07/2006 APPROVED CMINI
FOUNDATION SURVEY APPROVED BY STORMWATER 06/30/2006 APPROVED LAPTEKAR
MONOLITHIC SLAB INSPECTION/SLAB 06/22/2006 APPROVED CMINI
FIRST ROUGH PLUMBING INSPECTION 06/19/2006 APPROVED JHINDMAN
PRE DRIVEWAY 06/08/2006 APPROVED - AS NOTED GLALIMA
Note: Builder wants opinion about proposed FFE of 29.73' Builder stated that their company Engineer was going to re-evaluate the proposed elevation.

Review History

Department Status Date In Date Out
SW1 COMPLETE 03/20/2006 03/21/2006
Note: Released By: LAPTEKAR New topo received...FFE adjusted
BLD COMPLETE 02/23/2006 02/28/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
ZON COMPLETE 02/20/2006 02/23/2006
Note: Released By: ECOYNE
SW1 HOLD 03/08/2006
Note: Held By: LAPTEKAR The proposed elevations in the rear yard are too high in relation to the proposed FFE....Florida building code requires the grade away from the foundation walls to fall a minimum of 6" within the first 10'.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤292.00 11/09/2006
EARLY POWER INSPECTION ¤40.00 11/09/2006
REINSPECTION FEE ¤40.00 11/09/2006
REINSPECTION FEE ¤40.00 11/09/2006
REINSPECTION FEE ¤40.00 11/09/2006
STORMWATER REINSPECTION FEE ¤35.00 11/09/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 03/31/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 03/31/2006
STORM WATER PERMIT FEES ¤80.00 03/31/2006
ADMIN FEE ¤20.00 03/31/2006
ARC HOUSE REVIEW ¤125.00 03/31/2006
BUILDING CODE ADMIN FUND ¤13.68 03/31/2006
ELECTRIC FEE ¤150.00 03/31/2006
FIRE RES IMPACT FEE 4-1-05 ¤173.47 03/31/2006
MECHANICAL FEE ¤150.00 03/31/2006
PERMIT FEE ¤780.00 03/31/2006
PARKS IMPACT FEE 11-2-04 ¤1,120.91 03/31/2006
PLAN CHECK FEE ¤80.00 03/31/2006
PLUMBING FEE ¤150.00 03/31/2006
RADON FEE ¤13.68 03/31/2006
Fees Total Due: ¤0.00 Total Paid: ¤10,192.25