I want to search for...
Permit #2006020725
Permit Details
Status: COED
| Parcel Id: 27-11-31-0000-01010-0330 |
| CONDITIONED SPACE: 3472 sqft |
| GARAGE: 579 sqft |
| OPENED PORCH (WITH ROOF) : 275 sqft |
| OPENED PORCH (WITH ROOF) : 56 sqft |
| Total Square Footage: 4382 sqft |
| Subdivision: - |
| Job Phone: (904)363-7626 |
| Location Address: 13 LAKEVIEW LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/03/2006 |
| NOC: RECORDED |
| Owner: WEEKLEY HOMES |
|
Address 1111 N. POST OAK ROAD HOUSTON, TX 77055 |
| Lot: 33 |
| Contracted Stated Job Value: ¤320,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
WEEKLEY HOMES,L.P.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
448 VICTORIA HILLS DRIVE DELAND, FL 32724 |
CBC053082 (Exp: 08/31/2012) | (386)775-7206 | (386)775-1709 |
Sub Contractors
CHRISTIAN MASARIK
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
6321 GOMEZ ROAD ST. AUGUSTINE, FL 32084 |
EC13001175 (Exp: 08/31/2010) | (904)829-2700 | (904)829-2751 |
GARY WAYNE EVERS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 740106 ORANGE CITY, FL 32763 |
CFC050566 (Exp: 08/31/2026) | 386-775-0909 | 386-775-0918 |
TYRENE SCOTT
| Status | Location Address | State License Number |
| CANCEL |
9556 HISTORIC KINGS RD ST #306 JACKSONVILLE, FL 32206 |
CAC035526 (Exp: 09/30/2008) |
JEFFREY LUIS CARRASCO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
665 W. COUNTY ROAD 2006 BUNNELL, FL 32110 |
CCC1325557 (Exp: 08/31/2010) | 904-674-4730 | 904-268-0471 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 12/13/2006 | FINAL APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION Flood zone X , no certificate required Nestor 12/12/06 | |||
| FINAL COMPLETE BUILDING INSPECTION | 12/06/2006 | Disapproved - NO FEE | JGIBSON |
| Note: FLOOD ZONE ''A'' CERTIFICATE HAS NOT BEEN ISSUED. | |||
| FINAL COMPLETE BUILDING INSPECTION | 11/08/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: nedd house number. AHU needs to be #6 awg. need access to the spa motor. bathroom gfci needs to be GFCI. rec. within 6ft of kitchen sink needs to be GFCI. no dead front on disconnect upstairs. need energy sheet. strap LFNC every 2ft. service rec. needs to have an in-use cover. | |||
| UTILITY COMPANY FINAL | 11/06/2006 | APPROVED | DMITCHUM |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 10/05/2006 | Disapproved - NO FEE | JSHEVLIN |
| Note: FAILED, FIRE HYDRANT BURRIED LEFT SIDE OF PROPERTY LINE NEEDS TO BE RAISED 4" SEWER CLEAN OUT CONNECTED IN HOUSE DRIVE WAY SHOULD BE 6" AND OUT OF DRIVEWAY AND OUT OF THE DRIVEWAY | |||
| STORMWATER FINAL INSPECTION | 10/04/2006 | APPROVED | DRANDALL |
| RESIDENTIAL EARLY POWER | 09/29/2006 | APPROVED | JGIBSON |
| INSULATION INSPECTION | 06/14/2006 | APPROVED | CMINI |
| ALL ROUGH | 06/08/2006 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 06/01/2006 | APPROVED | JMCGOWEN |
| ALL ROUGH | 05/31/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: THIS IS A REINSPECTION see previous list | |||
| ALL ROUGH | 05/30/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: THIS IS A REINSPECTION previous list was not completed | |||
| ALL ROUGH | 05/23/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: strap wires within 12" of main electric panel , looks like one 12-3 wire has been cut at top of electric panel, conectors missing on metal boxes outside garage area, spa needs it's own 20 amp circut , electric conduit in kitchen area needs to extend 6" above finish floor, nail plates missing , fire stop missing many areas, not ready, incomplete list | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/09/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/05/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: fasten all straps. lateral brace missing. nail glue lams according to the schedule. rod missing on beam 7. triple lam missing htt 16. not ready. incomplete list.THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/27/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: loose all thread rods, straps missing, jack studs missing, wall bracing,not ready | |||
| LINTEL | 04/05/2006 | APPROVED | JMCGOWEN |
| FLOOD ZONE 'A' ELEVATION CERTIFICATE APPROVAL | 04/04/2006 | CANCELLED BY INSPECTOR | LAPTEKAR |
| Note: this was called in on the airs in error...a foundation survey was already submitted | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 04/04/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 03/24/2006 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 03/23/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: not ready. | |||
| FIRST ROUGH PLUMBING INSPECTION | 03/21/2006 | APPROVED | JMCGOWEN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/11/2006 | 10/12/2006 |
| Note: Released By: CCOTE Approved for Release. REVISION: Restamp plan set. Lost plans. | |||
| URB | COMPLETE | 02/23/2006 | 02/23/2006 |
| Note: Released By: CBENNETT | |||
| BLD | COMPLETE | 02/23/2006 | 03/01/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| SW1 | COMPLETE | 02/22/2006 | 03/02/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 02/22/2006 | 02/23/2006 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 12/20/2006 |
| REINSPECTION FEE | ¤40.00 | 12/20/2006 |
| REINSPECTION FEE | ¤40.00 | 12/20/2006 |
| REINSPECTION FEE | ¤40.00 | 12/20/2006 |
| REINSPECTION FEE | ¤40.00 | 12/20/2006 |
| REINSPECTION FEE | ¤40.00 | 12/20/2006 |
| REINSPECTION FEE | ¤40.00 | 12/20/2006 |
| REINSPECTION FEE | ¤40.00 | 12/20/2006 |
| REVISION | ¤40.00 | 12/20/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 03/03/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/03/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 03/03/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 03/03/2006 |
| MECHANICAL FEE | ¤227.40 | 03/03/2006 |
| PERMIT FEE | ¤1,283.10 | 03/03/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 03/03/2006 |
| PLAN CHECK FEE | ¤131.60 | 03/03/2006 |
| PLUMBING FEE | ¤227.40 | 03/03/2006 |
| RADON FEE | ¤21.91 | 03/03/2006 |
| ADMIN FEE | ¤20.00 | 03/03/2006 |
| BUILDING CODE ADMIN FUND | ¤21.91 | 03/03/2006 |
| ELECTRIC FEE | ¤227.40 | 03/03/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,743.61 |