I want to search for...
Permit #2006020936
Permit Details
Status: COED
| Parcel Id: 07-11-31-7027-00260-0020 |
| CONDITIONED SPACE: 2450 sqft |
| GARAGE: 660 sqft |
| OPENED PORCH (WITH ROOF) : 318 sqft |
| OPENED PORCH (WITH ROOF) : 67 sqft |
| Total Square Footage: 3495 sqft |
| Block: 00260 |
| Subdivision: - |
| Job Phone: (386) 445-2222 |
| Location Address: 46 WOODLAWN DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/23/2006 |
| NOC: RECORDED |
| Applicant name: MICHAEL STEPHAN MULLEN |
| Owner: JESUS A. MARTINEZ A MARRIED MAN |
|
Address 58 WHITE HALL DR PALM COAST, FL 32164 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤160,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
TOWN & COUNTRY HOMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1 Enterprise Drive Bunnell, FL 32110 |
CGC049972 (Exp: 08/31/2026) | (386) 445-2222 |
Sub Contractors
STEVEN DUANE DENSLOW
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. US # 1 Ormond Beach, FL 32174 |
EC0001678 (Exp: 08/31/2012) | (386) 672-8494 | (386)673-7856 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
DENNIS GENE GAINEY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P.O. BOX 1203 Bunnell, FL 32110 |
CFC046004 (Exp: 08/31/2026) | (386) 437-5637 | 386-437-3012 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 03/01/2007 | FINAL APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 02/28/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: NEED TO HAVE LIGHT SWITCH IN MASTER BD. ON ARC FAULT BREAKER. | |||
| STORMWATER FINAL INSPECTION | 02/27/2007 | APPROVED - AS NOTED | DRANDALL |
| Note: 38 sf road...$404 | |||
| UTILITY COMPANY FINAL | 02/23/2007 | APPROVED | MBACON |
| RESIDENTIAL EARLY POWER | 02/23/2007 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION NEED ANOTHER OULET TO RIGHT OF RANGE | |||
| PRE DRIVEWAY | 02/14/2007 | APPROVED | DRANDALL |
| Note: THIS IS A REINSPECTION | |||
| PRE DRIVEWAY | 02/13/2007 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: culvert pipe needs 50% coverage of concrete | |||
| RESIDENTIAL EARLY POWER | 01/31/2007 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: NEED TO BOX AND SECURE WIRES IN KITCHEN REC. ARC SHIELDS NEEDED IN KITCHEN REC. ALL WHITE WIRES NEED TO BE COLOR CODED HOT. | |||
| INSULATION INSPECTION | 12/07/2006 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 12/05/2006 | APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 12/01/2006 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: NOT READY. | |||
| INSULATION INSPECTION | 12/01/2006 | Disapproved - NO FEE | PGALLMANN |
| Note: 1) RIGID INSULATION MISSING AT TOP OF REAR WALL IN GREAT ROOM. 2) FIBERGLASS INSULATION MISSING, IN TWO BAYS, ABOVE RIGID INSULATION AT SAME LOCATION. | |||
| ALL ROUGH | 11/21/2006 | APPROVED | ACOOPER |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 11/16/2006 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: 1) CABLES NOT FASTENED ABOVE MAIN PANEL. 2) DRYER & KITCHEN EXHAUST VENTS ARE NOT SEALED, WITH FABRIC & MASTIC, AT ROOF PENETRATIONS. 3) CEMENT FILL MISSING AT REAR TUB TRAP. | |||
| TEMPORARY POLE | 10/04/2006 | APPROVED | RMARVEL |
| Note: CALLED SUSAN AT 8:32 ON 10/05/06 | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/27/2006 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/22/2006 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: no plans on site. | |||
| LINTEL | 08/23/2006 | APPROVED | ARITTER |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 08/18/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: THIS IS A REINSPECTION need revision for added window, missing dowels | |||
| LINTEL | 08/14/2006 | Disapproved -FEE REQUIRED | ARITTER |
| Note: dowels missing, need revision showing added window, clean out cell bottoms | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 07/21/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 07/14/2006 | APPROVED | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 07/05/2006 | APPROVED | ARITTER |
| Note: THIS IS A REINSPECTION | |||
| FIRST ROUGH PLUMBING INSPECTION | 06/26/2006 | Disapproved -FEE REQUIRED | ARITTER |
| Note: Plumbing lay out does not con form to house plans |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 06/29/2006 | 06/30/2006 |
| Note: Released By: LWOODROME Revision: Bath #2 and #3 location | |||
| BLD | COMPLETE | 03/02/2006 | 03/09/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| SW1 | COMPLETE | 02/28/2006 | 03/17/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 02/28/2006 | 03/02/2006 |
| Note: Released By: ECOYNE |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤404.00 | 03/02/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 03/02/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 03/02/2007 |
| REINSPECTION FEE | ¤40.00 | 03/02/2007 |
| REINSPECTION FEE | ¤40.00 | 03/02/2007 |
| REINSPECTION FEE | ¤40.00 | 03/02/2007 |
| REINSPECTION FEE | ¤40.00 | 03/02/2007 |
| REINSPECTION FEE | ¤40.00 | 03/02/2007 |
| REINSPECTION FEE | ¤40.00 | 03/02/2007 |
| REINSPECTION FEE | ¤40.00 | 03/02/2007 |
| REINSPECTION FEE | ¤40.00 | 03/02/2007 |
| REVISION | ¤40.00 | 03/02/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 03/02/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 03/23/2006 |
| ADMIN FEE | ¤20.00 | 03/23/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 03/23/2006 |
| BUILDING CODE ADMIN FUND | ¤17.48 | 03/23/2006 |
| ELECTRIC FEE | ¤178.20 | 03/23/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 03/23/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/23/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 03/23/2006 |
| MECHANICAL FEE | ¤178.20 | 03/23/2006 |
| PERMIT FEE | ¤963.30 | 03/23/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 03/23/2006 |
| PLAN CHECK FEE | ¤98.80 | 03/23/2006 |
| PLUMBING FEE | ¤178.20 | 03/23/2006 |
| RADON FEE | ¤17.48 | 03/23/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,878.55 |