Status: COED
| Parcel Id: 07-11-31-7010-00020-0200 |
| CONDITIONED SPACE: 2077 sqft |
| GARAGE: 454 sqft |
| OPENED PORCH (WITH ROOF) : 263 sqft |
| OPENED PORCH (WITH ROOF) : 61 sqft |
| Total Square Footage: 2855 sqft |
| Block: 00020 |
| Subdivision: - |
| Job Phone: (386)445-9009 |
| Location Address: 3 FERNGATE LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/13/2006 |
| NOC: RECORDED |
| Applicant name: BRIAN ANDREW GAZZOLI |
| Owner: JOHN AND REBECCA GRIMM |
|
Address 3 FELING LANE PALM COAST, FL 32164 |
| Lot: 0200 |
| Contracted Stated Job Value: ¤184,008.00 |
| Job Description: SINGLE FAMILY RESDIENCE |
| Type: CN |
Contractor
SEAGATE HOMES INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
185 CYPRESS POINT PARKWAY Palm Coast, FL 32137 |
SUITE 7 Palm Coast, FL 32137 |
CRC057202 (Exp: 08/31/2010) | 386-246-6125 | 386-246-6124 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
DENNIS MICHAEL IRWIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO Box 220 OCALA, FL 34472 |
CFC057438 (Exp: 08/31/2010) | (352)427-3887 | (352)687-9425 |
MILLARD K KELLER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
313 S. VOLUSIA AVENUE DELAND, FL 32724 |
CCC1325778 (Exp: 08/31/2010) | (386) 774-9961 | (386)774-2388 |
Inspection History
| Type | Request Date | Result | Inspector |
| STORMWATER FINAL INSPECTION | 02/01/2007 | FINAL APPROVED | DRANDALL |
| Note: check road repair...road damage repaired | |||
| FINAL COMPLETE BUILDING INSPECTION | 02/01/2007 | FINAL APPROVED | JGIBSON |
| Note: | |||
| STORMWATER FINAL INSPECTION | 01/30/2007 | APPROVED - AS NOTED | DRANDALL |
| Note: 22 sf road | |||
| STORMWATER FINAL INSPECTION | 01/29/2007 | CANCELLED BY INSPECTOR | LAPTEKAR |
| Note: duplicate inspection | |||
| UTILITY COMPANY FINAL | 01/18/2007 | APPROVED | TSCHWEERS |
| PRE DRIVEWAY | 01/08/2007 | APPROVED | DRANDALL |
| RESIDENTIAL EARLY POWER | 12/21/2006 | APPROVED | LHITES |
| RESIDENTIAL EARLY POWER | 12/15/2006 | APPROVED | LHITES |
| LATH /BRICK FLASHING | 11/16/2006 | APPROVED | JGIBSON |
| INSULATION INSPECTION | 11/15/2006 | APPROVED | RMARVEL |
| ALL ROUGH | 11/13/2006 | APPROVED | JMCGOWEN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/03/2006 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/02/2006 | Disapproved -FEE REQUIRED | LHITES |
| Note: 1) NEED LEDGER BOARD-MASTER BATH GABLE 2) X-BRACING IN GARAGE NEEDS TO BE 4 BAYS | |||
| LINTEL | 10/18/2006 | APPROVED | ACOOPER |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 10/16/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 10/02/2006 | APPROVED | JGIBSON |
| FIRST ROUGH PLUMBING INSPECTION | 09/22/2006 | APPROVED | LHITES |
Review History
| Department | Status | Date In | Date Out |
| URB | COMPLETE | 08/09/2006 | 08/14/2006 |
| Note: Released By: CBENNETT CB 8/14/06 Lot has already been cleared. | |||
| ZON | CANCEL | 08/04/2006 | |
| Note: forwarded to URB for review | |||
| SW1 | COMPLETE | 04/04/2006 | 07/12/2006 |
| Note: Released By: LAPTEKAR received new culvert proposals 7/12 | |||
| BLD | COMPLETE | 03/06/2006 | 03/09/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| SW1 | HOLD | 02/28/2006 | 03/20/2006 |
| Note: Held By: LAPTEKAR The proposed culvert invert elevations are too high. | |||
| ZON | COMPLETE | 02/28/2006 | 03/06/2006 |
| Note: Released By: ECOYNE |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 02/05/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 02/05/2007 |
| REINSPECTION FEE | ¤40.00 | 02/05/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 02/05/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 07/13/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 07/13/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 07/13/2006 |
| ADMIN FEE | ¤20.00 | 07/13/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 07/13/2006 |
| BUILDING CODE ADMIN FUND | ¤14.28 | 07/13/2006 |
| ELECTRIC FEE | ¤153.00 | 07/13/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 07/13/2006 |
| MECHANICAL FEE | ¤153.00 | 07/13/2006 |
| PERMIT FEE | ¤799.50 | 07/13/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 07/13/2006 |
| PLAN CHECK FEE | ¤82.00 | 07/13/2006 |
| PLUMBING FEE | ¤153.00 | 07/13/2006 |
| RADON FEE | ¤14.28 | 07/13/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,891.95 |