I want to search for...
Permit #2006020967
Permit Details
Status: COED
| Parcel Id: 27-11-31-5906-0000-0200 |
| CONDITIONED SPACE: 2586 sqft |
| GARAGE: 496 sqft |
| OPENED PORCH (WITH ROOF) : 390 sqft |
| OPENED PORCH (WITH ROOF) : 200 sqft |
| OPENED PORCH (WITH ROOF) : 77 sqft |
| Total Square Footage: 3749 sqft |
| Block: 000- |
| Subdivision: - |
| Job Phone: (386) 445-4747 |
| Location Address: 43 EASTLAKE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/30/2006 |
| NOC: RECORDED |
| Applicant name: WILLIAM VALENTINE GROFF |
| Owner: CORY S & TINA M HOFFMAN |
|
Address 43182 TUTHILL LANE SOUTH RIDING, VA 20152 |
| Lot: 20 |
| Contracted Stated Job Value: ¤320,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
COUNTRY CLUB HOMES OF FLORIDA, INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
4440 N. Oceanshore Blvd Palm Coast, FL 32137 |
SUITE 101 Palm Coast, FL 32137 |
CRC043737 (Exp: 08/31/2012) | (386) 445-4747 | (386)445-5955 |
Sub Contractors
STEVEN DUANE DENSLOW
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. US # 1 Ormond Beach, FL 32174 |
EC0001678 (Exp: 08/31/2012) | (386) 672-8494 | (386)673-7856 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
GARY S WELBORN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1709 North Nova Road Holly Hill, FL 32117 |
CFC037140 (Exp: 08/31/2018) | (386) 257-1172 | (386)252-5979 |
WAYNE STEED
| Status | Location Address | State License Number | Phone |
| CANCEL |
318 N. PINE AVENUE IVERNESS, FL 34450 |
CCC058299 (Exp: 08/31/2010) | (352)637-2422 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 01/22/2007 | FINAL APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 01/17/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: j-box at acu needs a connector. all white wires used as hots need to be marked as such. need arc shields on counter rec. fl. light in master closet needs to clear the shelf by 6in. missing the vent grill in master bath. | |||
| FINAL COMPLETE BUILDING INSPECTION | 12/28/2006 | CANCELLED BY APPLICANT | AIRS WEB |
| UTILITY COMPANY FINAL | 12/19/2006 | APPROVED | TSCHWEERS |
| STORMWATER FINAL INSPECTION | 12/14/2006 | APPROVED | DRANDALL |
| RESIDENTIAL EARLY POWER | 11/08/2006 | APPROVED | LHITES |
| RESIDENTIAL EARLY POWER | 08/18/2006 | APPROVED | KSAMPICO |
| Note: ---TUG--- | |||
| INSULATION INSPECTION | 08/08/2006 | APPROVED - AS NOTED | JGIBSON |
| Note: LEFT NOTICE OF NON-- COMPLIANCE ABOUT MISSING LATH INSPECTION. | |||
| GAS ROUGH | 07/28/2006 | APPROVED | JMCGOWEN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/27/2006 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 07/27/2006 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 07/26/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: roof sheathing inspection is still outstandingS.E. cable needs to be installed, box out over panel, outlets missing in living room and breakfast bar area, fire stop missing, relocate smoke detectors 6' from possible celing fan areas | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/24/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION.STILL INCOMPLETE LIST FROM NONCOMPLIACE MISSING ENGINEERING ON TRUSSES T-39,T-36,T-18 CELL OK .ALRIGHT TO LOAD ROOF. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/23/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION.NEED ENGINEERING PACK ON SITE.BEAM MISSING ON BACK PORCH. NOT ENOUGH BEARING ON SHORT BEAM,BACK BEAM NEED TO BE EXPOSED FOR INSPECTION. LOOSE BOLT CONNECTION AT GARAGE WALL.NO CONNECTION CAN BE SEEN AT TRUSS T37 FRONT ENTRY SIDE. NOT READY. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/22/2006 | CANCELLED BY APPLICANT | CMINI |
| TEMPORARY POLE | 05/18/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION.NEED TO CALL IN FOR AN EARLY POWER FOR A TUG NOT TEMP POLE. NEED TO FILL OUT AFFIDAVIDT WITH CITY. | |||
| LINTEL | 05/02/2006 | APPROVED | CMINI |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 05/01/2006 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 04/20/2006 | APPROVED | JMCGOWEN |
| TEMPORARY POLE | 04/20/2006 | CANCELLED BY APPLICANT | JMCGOWEN |
| FIRST ROUGH PLUMBING INSPECTION | 04/17/2006 | APPROVED | JMCGOWEN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/24/2006 | 03/29/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| BLD | HOLD | 03/06/2006 | 03/09/2006 |
| Note: Held By: JJOSEPH Based on the plan review detail 5/S2.1 was considered to be the typical roof truss to cmu connection detail. This detail shows a single top plate that conflicts with detail 6/S2.1 and other notes found on the drawings referring to a double top plate. Please clarify where double and single top plates are to be located. If double top plates are to be located everywhere then submit two copies of a signed and sealed revised detail 5/S2.1. Specify the connectors schedule in each point (Truss) | |||
| URB | COMPLETE | 03/03/2006 | 03/06/2006 |
| Note: Released By: CBENNETT | |||
| SW1 | COMPLETE | 02/28/2006 | 03/14/2006 |
| Note: Released By: WKINELL | |||
| ZON | COMPLETE | 02/28/2006 | 03/03/2006 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 02/07/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 02/07/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 02/07/2007 |
| REINSPECTION FEE | ¤40.00 | 02/07/2007 |
| REINSPECTION FEE | ¤40.00 | 02/07/2007 |
| REINSPECTION FEE | ¤40.00 | 02/07/2007 |
| REINSPECTION FEE | ¤40.00 | 02/07/2007 |
| REINSPECTION FEE | ¤40.00 | 02/07/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 03/30/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/30/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 03/30/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 03/30/2006 |
| MECHANICAL FEE | ¤222.00 | 03/30/2006 |
| PERMIT FEE | ¤1,248.00 | 03/30/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 03/30/2006 |
| PLAN CHECK FEE | ¤128.00 | 03/30/2006 |
| PLUMBING FEE | ¤222.00 | 03/30/2006 |
| RADON FEE | ¤18.75 | 03/30/2006 |
| ADMIN FEE | ¤20.00 | 03/30/2006 |
| BUILDING CODE ADMIN FUND | ¤18.75 | 03/30/2006 |
| ELECTRIC FEE | ¤222.00 | 03/30/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,642.39 |